CONCERT (VERIDIC) project [662287]

Link to this page

CONCERT (VERIDIC) project [662287]

Authors

Publications

Review of skin dose calculation software in interventional cardiology

Malchair, Françoise; Dabin, Jérémie; Deleu, Marine; Merce, Marta Sans; Ciraj-Bjelac, Olivera; Gallagher, Aoife; Maccia, Carlo

(2020)

TY  - JOUR
AU  - Malchair, Françoise
AU  - Dabin, Jérémie
AU  - Deleu, Marine
AU  - Merce, Marta Sans
AU  - Ciraj-Bjelac, Olivera
AU  - Gallagher, Aoife
AU  - Maccia, Carlo
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9714
AB  - PurposeIn interventional cardiology, patients may be exposed to high doses to the skin resulting in skin burns following single or multiple procedures. Reviewing and analysing available software (online or offline) may help medical physicists assessing the maximum skin dose to the patient together with the dose distribution during (or after) these procedures.Method and resultsCapabilities and accuracy of available software were analysed through an extensive bibliography search and contacts with both vendor and authors. Their markedly differed among developers. In total, 22 software were identified and reviewed according to their algorithms and their capabilities. Special attention was dedicated to their main features and limitations of interest for the intended clinical use. While the accuracy of the 12 software products validated with measurements on phantoms was acceptable (within ± 25%), the agreement was poor for the two products validated on patients (within ± 43% and ± 76%, respectively). In addition, no software has been validated on angiographic units from all manufacturers, though several software developers claimed vendor-independent transportability. Only one software allows for multiple procedures dose calculation.ConclusionLarge differences among vendors made it clear that work remains to be done before an accurate and reliable skin dose mapping is available for all patients.
T2  - Physica Medica
T1  - Review of skin dose calculation software in interventional cardiology
VL  - 80
SP  - 75
EP  - 83
DO  - 10.1016/j.ejmp.2020.09.023
ER  - 
@article{
author = "Malchair, Françoise and Dabin, Jérémie and Deleu, Marine and Merce, Marta Sans and Ciraj-Bjelac, Olivera and Gallagher, Aoife and Maccia, Carlo",
year = "2020",
abstract = "PurposeIn interventional cardiology, patients may be exposed to high doses to the skin resulting in skin burns following single or multiple procedures. Reviewing and analysing available software (online or offline) may help medical physicists assessing the maximum skin dose to the patient together with the dose distribution during (or after) these procedures.Method and resultsCapabilities and accuracy of available software were analysed through an extensive bibliography search and contacts with both vendor and authors. Their markedly differed among developers. In total, 22 software were identified and reviewed according to their algorithms and their capabilities. Special attention was dedicated to their main features and limitations of interest for the intended clinical use. While the accuracy of the 12 software products validated with measurements on phantoms was acceptable (within ± 25%), the agreement was poor for the two products validated on patients (within ± 43% and ± 76%, respectively). In addition, no software has been validated on angiographic units from all manufacturers, though several software developers claimed vendor-independent transportability. Only one software allows for multiple procedures dose calculation.ConclusionLarge differences among vendors made it clear that work remains to be done before an accurate and reliable skin dose mapping is available for all patients.",
journal = "Physica Medica",
title = "Review of skin dose calculation software in interventional cardiology",
volume = "80",
pages = "75-83",
doi = "10.1016/j.ejmp.2020.09.023"
}
Malchair, F., Dabin, J., Deleu, M., Merce, M. S., Ciraj-Bjelac, O., Gallagher, A.,& Maccia, C.. (2020). Review of skin dose calculation software in interventional cardiology. in Physica Medica, 80, 75-83.
https://doi.org/10.1016/j.ejmp.2020.09.023
Malchair F, Dabin J, Deleu M, Merce MS, Ciraj-Bjelac O, Gallagher A, Maccia C. Review of skin dose calculation software in interventional cardiology. in Physica Medica. 2020;80:75-83.
doi:10.1016/j.ejmp.2020.09.023 .
Malchair, Françoise, Dabin, Jérémie, Deleu, Marine, Merce, Marta Sans, Ciraj-Bjelac, Olivera, Gallagher, Aoife, Maccia, Carlo, "Review of skin dose calculation software in interventional cardiology" in Physica Medica, 80 (2020):75-83,
https://doi.org/10.1016/j.ejmp.2020.09.023 . .
1
20
12
17