Cadmium Zinc Telluride solid-state detector characterisation for its use as a spectro-dosemeter

Kržanović, Nikola; Röttger, Annette; Morosh, Viacheslav; Luchkov, Maksym; Neumaier, Stefan

(Niš : Sievert Association, 2019)

TY  - CONF
AU  - Kržanović, Nikola
AU  - Röttger, Annette
AU  - Morosh, Viacheslav
AU  - Luchkov, Maksym
AU  - Neumaier, Stefan
PY  - 2019
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11919
AB  - Concerning ionising radiation monitoring in the environment in areas which, by normal means, are inaccessible, e.g. in contaminated areas after a nuclear or radiological incident, the use of highly mobile systems, comprising of unmanned airborne vehicles equipped with ionising radiation detector, is advised in order to protect the health and the life of first responders. As a promising candidate, the compact solid-state spectrometer based on CdZnTe is characterised by performing irradiations in the reference radionuclide radiation fields of PTB. The energydependent conversion coefficients are derived from recorded pulse-height spectra, and they enable calculation of the operational radiation protection quantity, ambient dose equivalent rate, directly from the spectrum without deconvolution. The validity of the conversion coefficients was evaluated by determining the deviation of the calculated dose rate from the reference ambient dose equivalent rate for the 226Ra radionuclide, available at the Underground Dosimetry Laboratory (UDO II) of PTB. By employing the derived conversion coefficients, the detector “linearity” (dose rate dependence of the response) was checked in the 137Cs reference fields of different ambient dose equivalent rates ranging from 25 nSv/h up to 1 μSv/h. The deviation of the calculated 226Ra dose rate from the achieved reference value was +2%.
PB  - Niš : Sievert Association
C3  - RAP 2019 : International conference on radiation applications; Proceedings book
T1  - Cadmium Zinc Telluride solid-state detector characterisation for its use as a spectro-dosemeter
SP  - 148
EP  - 151
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11919
ER  - 
@conference{
author = "Kržanović, Nikola and Röttger, Annette and Morosh, Viacheslav and Luchkov, Maksym and Neumaier, Stefan",
year = "2019",
abstract = "Concerning ionising radiation monitoring in the environment in areas which, by normal means, are inaccessible, e.g. in contaminated areas after a nuclear or radiological incident, the use of highly mobile systems, comprising of unmanned airborne vehicles equipped with ionising radiation detector, is advised in order to protect the health and the life of first responders. As a promising candidate, the compact solid-state spectrometer based on CdZnTe is characterised by performing irradiations in the reference radionuclide radiation fields of PTB. The energydependent conversion coefficients are derived from recorded pulse-height spectra, and they enable calculation of the operational radiation protection quantity, ambient dose equivalent rate, directly from the spectrum without deconvolution. The validity of the conversion coefficients was evaluated by determining the deviation of the calculated dose rate from the reference ambient dose equivalent rate for the 226Ra radionuclide, available at the Underground Dosimetry Laboratory (UDO II) of PTB. By employing the derived conversion coefficients, the detector “linearity” (dose rate dependence of the response) was checked in the 137Cs reference fields of different ambient dose equivalent rates ranging from 25 nSv/h up to 1 μSv/h. The deviation of the calculated 226Ra dose rate from the achieved reference value was +2%.",
publisher = "Niš : Sievert Association",
journal = "RAP 2019 : International conference on radiation applications; Proceedings book",
title = "Cadmium Zinc Telluride solid-state detector characterisation for its use as a spectro-dosemeter",
pages = "148-151",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11919"
}
Kržanović, N., Röttger, A., Morosh, V., Luchkov, M.,& Neumaier, S.. (2019). Cadmium Zinc Telluride solid-state detector characterisation for its use as a spectro-dosemeter. in RAP 2019 : International conference on radiation applications; Proceedings book
Niš : Sievert Association., 148-151.
https://hdl.handle.net/21.15107/rcub_vinar_11919
Kržanović N, Röttger A, Morosh V, Luchkov M, Neumaier S. Cadmium Zinc Telluride solid-state detector characterisation for its use as a spectro-dosemeter. in RAP 2019 : International conference on radiation applications; Proceedings book. 2019;:148-151.
https://hdl.handle.net/21.15107/rcub_vinar_11919 .
Kržanović, Nikola, Röttger, Annette, Morosh, Viacheslav, Luchkov, Maksym, Neumaier, Stefan, "Cadmium Zinc Telluride solid-state detector characterisation for its use as a spectro-dosemeter" in RAP 2019 : International conference on radiation applications; Proceedings book (2019):148-151,
https://hdl.handle.net/21.15107/rcub_vinar_11919 .