EMPIR [14RPT05 – Eura-Thermal]

Link to this page

EMPIR [14RPT05 – Eura-Thermal]

Authors

Publications

Inter-laboratory comparison on thermal conductivity measurements by the guarded hot plate method between LNE and Institute VINCA

Hay, Bruno; Milošević, Nenad D.; Hameury, Jacques; Stepanić, Nenad; Failleau, Guillaume; Garcia, Yann; Koenen, Alain; Filtz, Jen-Remy

(2021)

TY  - JOUR
AU  - Hay, Bruno
AU  - Milošević, Nenad D.
AU  - Hameury, Jacques
AU  - Stepanić, Nenad
AU  - Failleau, Guillaume
AU  - Garcia, Yann
AU  - Koenen, Alain
AU  - Filtz, Jen-Remy
PY  - 2021
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9977
AB  - Institute VINCA, respectively French National Metrology Institute and Serbian Designated Institute for thermal properties metrology, on thermal conductivity measurements by the guarded hot plate method. The main objective was to validate the measurement capabilities of VINCA in terms of thermal conductivity in the temperature range from 10 degrees C to 50 degrees C by using the facility improved in the frame of the European project Eura-Thermal. The measurements were carried out on expanded polystyrene boards using guarded hot plate apparatuses (two-specimen GHP apparatuses) in accordance with the international standard ISO 8302. The measurement programme was defined taking into account the major characteristics of the guarded hot plate apparatuses used, such as specimen dimensions and temperature and thermal conductivity ranges. Specimens were machined by LNE from a same batch for both participants. Prior to the measurements, the homogeneity of the set of specimens, as well as the influence of a variation of density of the expanded polystyrene on the thermal conductivity measurements were studied by VINCA. The obtained results showed good agreement between the two laboratories, with relative deviations within the uncertainties of measurement. Also, the results validated the level of uncertainty assessed by VINCA for its thermal conductivity measurements to around 2.5 % (with a coverage factor of 2) between 10 degrees C and 50 degrees C.
T2  - High Temperatures: High Pressures
T1  - Inter-laboratory comparison on thermal conductivity measurements by the guarded hot plate method between LNE and Institute VINCA
VL  - 50
IS  - 3
SP  - 213
EP  - 231
DO  - 10.32908/hthp.v50.1001
ER  - 
@article{
author = "Hay, Bruno and Milošević, Nenad D. and Hameury, Jacques and Stepanić, Nenad and Failleau, Guillaume and Garcia, Yann and Koenen, Alain and Filtz, Jen-Remy",
year = "2021",
abstract = "Institute VINCA, respectively French National Metrology Institute and Serbian Designated Institute for thermal properties metrology, on thermal conductivity measurements by the guarded hot plate method. The main objective was to validate the measurement capabilities of VINCA in terms of thermal conductivity in the temperature range from 10 degrees C to 50 degrees C by using the facility improved in the frame of the European project Eura-Thermal. The measurements were carried out on expanded polystyrene boards using guarded hot plate apparatuses (two-specimen GHP apparatuses) in accordance with the international standard ISO 8302. The measurement programme was defined taking into account the major characteristics of the guarded hot plate apparatuses used, such as specimen dimensions and temperature and thermal conductivity ranges. Specimens were machined by LNE from a same batch for both participants. Prior to the measurements, the homogeneity of the set of specimens, as well as the influence of a variation of density of the expanded polystyrene on the thermal conductivity measurements were studied by VINCA. The obtained results showed good agreement between the two laboratories, with relative deviations within the uncertainties of measurement. Also, the results validated the level of uncertainty assessed by VINCA for its thermal conductivity measurements to around 2.5 % (with a coverage factor of 2) between 10 degrees C and 50 degrees C.",
journal = "High Temperatures: High Pressures",
title = "Inter-laboratory comparison on thermal conductivity measurements by the guarded hot plate method between LNE and Institute VINCA",
volume = "50",
number = "3",
pages = "213-231",
doi = "10.32908/hthp.v50.1001"
}
Hay, B., Milošević, N. D., Hameury, J., Stepanić, N., Failleau, G., Garcia, Y., Koenen, A.,& Filtz, J.. (2021). Inter-laboratory comparison on thermal conductivity measurements by the guarded hot plate method between LNE and Institute VINCA. in High Temperatures: High Pressures, 50(3), 213-231.
https://doi.org/10.32908/hthp.v50.1001
Hay B, Milošević ND, Hameury J, Stepanić N, Failleau G, Garcia Y, Koenen A, Filtz J. Inter-laboratory comparison on thermal conductivity measurements by the guarded hot plate method between LNE and Institute VINCA. in High Temperatures: High Pressures. 2021;50(3):213-231.
doi:10.32908/hthp.v50.1001 .
Hay, Bruno, Milošević, Nenad D., Hameury, Jacques, Stepanić, Nenad, Failleau, Guillaume, Garcia, Yann, Koenen, Alain, Filtz, Jen-Remy, "Inter-laboratory comparison on thermal conductivity measurements by the guarded hot plate method between LNE and Institute VINCA" in High Temperatures: High Pressures, 50, no. 3 (2021):213-231,
https://doi.org/10.32908/hthp.v50.1001 . .
1
1