Dose mapping of products with different density irradiated in 60co irradiation facility of the Vinca institute, Serbia

Ranković, Bojan; Nikolić, Nikolina; Mašić, Slobodan; Vujčić, Ivica

(2020)

TY  - JOUR
AU  - Ranković, Bojan
AU  - Nikolić, Nikolina
AU  - Mašić, Slobodan
AU  - Vujčić, Ivica
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9596
AB  - The distribution of the absorbed dose within the irradiated product is a complex function of the product density and homogeneity, the position and shape of the radiation source, as well as the design of the irradiator. In this paper, detailed mapping of absorbed radiation doses in products of different density: gauze, plastic, and soil, is performed. Positions of minimum and maximum absorbed radiation dose were determined, and the homogeneity of irradiation of products was calculated using the ethanol-monochlorobenzene oscillotitrator dosimetry system. © 2020, Vinca Inst Nuclear Sci. All rights reserved.
T2  - Nuclear Technology and Radiation Protection
T1  - Dose mapping of products with different density irradiated in 60co irradiation facility of the Vinca institute, Serbia
VL  - 35
IS  - 1
SP  - 56
EP  - 63
DO  - 10.2298/NTRP2001056R
ER  - 
@article{
author = "Ranković, Bojan and Nikolić, Nikolina and Mašić, Slobodan and Vujčić, Ivica",
year = "2020",
abstract = "The distribution of the absorbed dose within the irradiated product is a complex function of the product density and homogeneity, the position and shape of the radiation source, as well as the design of the irradiator. In this paper, detailed mapping of absorbed radiation doses in products of different density: gauze, plastic, and soil, is performed. Positions of minimum and maximum absorbed radiation dose were determined, and the homogeneity of irradiation of products was calculated using the ethanol-monochlorobenzene oscillotitrator dosimetry system. © 2020, Vinca Inst Nuclear Sci. All rights reserved.",
journal = "Nuclear Technology and Radiation Protection",
title = "Dose mapping of products with different density irradiated in 60co irradiation facility of the Vinca institute, Serbia",
volume = "35",
number = "1",
pages = "56-63",
doi = "10.2298/NTRP2001056R"
}
Ranković, B., Nikolić, N., Mašić, S.,& Vujčić, I.. (2020). Dose mapping of products with different density irradiated in 60co irradiation facility of the Vinca institute, Serbia. in Nuclear Technology and Radiation Protection, 35(1), 56-63.
https://doi.org/10.2298/NTRP2001056R
Ranković B, Nikolić N, Mašić S, Vujčić I. Dose mapping of products with different density irradiated in 60co irradiation facility of the Vinca institute, Serbia. in Nuclear Technology and Radiation Protection. 2020;35(1):56-63.
doi:10.2298/NTRP2001056R .
Ranković, Bojan, Nikolić, Nikolina, Mašić, Slobodan, Vujčić, Ivica, "Dose mapping of products with different density irradiated in 60co irradiation facility of the Vinca institute, Serbia" in Nuclear Technology and Radiation Protection, 35, no. 1 (2020):56-63,
https://doi.org/10.2298/NTRP2001056R . .
1
1