FMSR (Austria), FNRS (Belgium), CNPq (Brazil), CAPES (Brazil), FAPERJ (Brazil), FAPESP (Brazil), MES (Bulgaria), CERN, CAS (China), MoST (China), NSFC (China), COLCIENCIAS (Colombia), MSES (Croatia), RPF (Cyprus), Academy of Sciences, NICPB (Estonia), Academy of Finland, ME (Finland), HIP (Finland), CEA (France), CNRS/IN2P3 (France), BMBF, Germany, DFG (Germany), HGF (Germany), GSRT (Greece), OTKA (Hungary), NKTH (Hungary), DAE (India), DST (India), IPM (Iran), SFI (Ireland), INFN (Italy), NRF (Korea), LAS (Lithuania), CINVESTAV (Mexico), CONACYT (Mexico), SEP (Mexico), UASLP-FAI (Mexico), PAEC (Pakistan), SCSR (Poland), FCT (Portugal), JINR (Armenia), JINR (Belarus), JINR (Georgia), JINR (Ukraine), JINR (Uzbekistan), MST (Russia), MAE (Russia), MSTDS (Serbia), MICINN (Spain), CPAN (Spain), Swiss Funding Agencies (Switzerland), NSC (Taipei), TUBITAK (Turkey), TAEK (Turkey), STFC (United Kingdom), DOE (USA), NSF (USA), European Union, Leventis Foundation, A.P. Sloan Foundation, Alexander von Humboldt Foundation, FWO (Belgium)

Link to this page

FMSR (Austria), FNRS (Belgium), CNPq (Brazil), CAPES (Brazil), FAPERJ (Brazil), FAPESP (Brazil), MES (Bulgaria), CERN, CAS (China), MoST (China), NSFC (China), COLCIENCIAS (Colombia), MSES (Croatia), RPF (Cyprus), Academy of Sciences, NICPB (Estonia), Academy of Finland, ME (Finland), HIP (Finland), CEA (France), CNRS/IN2P3 (France), BMBF, Germany, DFG (Germany), HGF (Germany), GSRT (Greece), OTKA (Hungary), NKTH (Hungary), DAE (India), DST (India), IPM (Iran), SFI (Ireland), INFN (Italy), NRF (Korea), LAS (Lithuania), CINVESTAV (Mexico), CONACYT (Mexico), SEP (Mexico), UASLP-FAI (Mexico), PAEC (Pakistan), SCSR (Poland), FCT (Portugal), JINR (Armenia), JINR (Belarus), JINR (Georgia), JINR (Ukraine), JINR (Uzbekistan), MST (Russia), MAE (Russia), MSTDS (Serbia), MICINN (Spain), CPAN (Spain), Swiss Funding Agencies (Switzerland), NSC (Taipei), TUBITAK (Turkey), TAEK (Turkey), STFC (United Kingdom), DOE (USA), NSF (USA), European Union, Leventis Foundation, A.P. Sloan Foundation, Alexander von Humboldt Foundation, FWO (Belgium)

Authors

Publications

Performance of the CMS cathode strip chambers with cosmic rays

Chatrchyan, S.; Adžić, Petar; Đorđević, Miloš; Jovanović, Dragana J.; Krpić, D.; Maletić, Dimitrije; Puzović, Jovan M.; Smiljković, Nikola; Milenović, Predrag

(2010)

TY  - JOUR
AU  - Chatrchyan, S.
AU  - Adžić, Petar
AU  - Đorđević, Miloš
AU  - Jovanović, Dragana J.
AU  - Krpić, D.
AU  - Maletić, Dimitrije
AU  - Puzović, Jovan M.
AU  - Smiljković, Nikola
AU  - Milenović, Predrag
PY  - 2010
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/4066
AB  - The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 mu m to 243 mu m. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns.
T2  - Journal of Instrumentation
T1  - Performance of the CMS cathode strip chambers with cosmic rays
VL  - 5
DO  - 10.1088/1748-0221/5/03/T03018
ER  - 
@article{
author = "Chatrchyan, S. and Adžić, Petar and Đorđević, Miloš and Jovanović, Dragana J. and Krpić, D. and Maletić, Dimitrije and Puzović, Jovan M. and Smiljković, Nikola and Milenović, Predrag",
year = "2010",
abstract = "The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 mu m to 243 mu m. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns.",
journal = "Journal of Instrumentation",
title = "Performance of the CMS cathode strip chambers with cosmic rays",
volume = "5",
doi = "10.1088/1748-0221/5/03/T03018"
}
Chatrchyan, S., Adžić, P., Đorđević, M., Jovanović, D. J., Krpić, D., Maletić, D., Puzović, J. M., Smiljković, N.,& Milenović, P.. (2010). Performance of the CMS cathode strip chambers with cosmic rays. in Journal of Instrumentation, 5.
https://doi.org/10.1088/1748-0221/5/03/T03018
Chatrchyan S, Adžić P, Đorđević M, Jovanović DJ, Krpić D, Maletić D, Puzović JM, Smiljković N, Milenović P. Performance of the CMS cathode strip chambers with cosmic rays. in Journal of Instrumentation. 2010;5.
doi:10.1088/1748-0221/5/03/T03018 .
Chatrchyan, S., Adžić, Petar, Đorđević, Miloš, Jovanović, Dragana J., Krpić, D., Maletić, Dimitrije, Puzović, Jovan M., Smiljković, Nikola, Milenović, Predrag, "Performance of the CMS cathode strip chambers with cosmic rays" in Journal of Instrumentation, 5 (2010),
https://doi.org/10.1088/1748-0221/5/03/T03018 . .
1
16
33
35