Publications

Rapid LSC method for direct alpha/beta measurements in waters

Stojković, Ivana; Todorović, Nataša; Nikolov, Jovana; Tenjović, Branislava

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2017)

TY  - CONF
AU  - Stojković, Ivana
AU  - Todorović, Nataša
AU  - Nikolov, Jovana
AU  - Tenjović, Branislava
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8326
UR  - https://plus.sr.cobiss.net/opac7/bib/245691404
UR  - http://dzz.org.rs/wp-content/uploads/2013/06/Zbornik_XXIX_Simpozijum_DZZ_SCG_Srebrno_jezero_2.pdf
AB  - Monitoring of environmental samples, drinking and surface waters, is continuously
carried out, demanding development of methods that are both reliable and accurate on
one side, but as simple and fast as possible, on the other. Screening tests such as gross
alpha/beta activity measurements in water samples are one liquid scintillation counting
(LSC) technique widely used as an efficient tool for radiological assesment and
estimation whether water sample needs further analysis or not. In this paper,
establishment of rapid gross alpha/beta screening technique in waters has been
presented, which assumes modification of conventional ASTM D 7283-06 method, since
samples were directly mixed with liquid scintillation cocktail, without any sample
pretreatment. Method’s optimization involved sample-to-cocktail ratio determination
based on the achieved detection limit and sample’s quench level. Optimal value of Pulse
Shape Analysis (PSA) discriminator that considerably improves performance of LSC
technique through alpha/beta spectra separation during radiological quality
measurements of drinking waters has also been investigated. Results of calibration
experiments and method’s validity measurements on spiked samples with 241Am and
90Sr/90Y aqueous standards are presented. Achieved detection limits for 300 minutes
of counting are MDAα=0.294(11) Bq l-1 and MDAβ=0.405(5) Bq l-1, in alpha and beta
window, respectively. Direct alpha/beta method provides deviations up to 40% from
reference values, but it offers advantages over conventional alpha/beta measurements,
it is ultra fast, simple and inexpensive test for efficient screening of water samples.
AB  - Rutinski monitoring pijaćih i površinskih voda sprovodi se kontinuirano i nameće
potrebu za razvojem metoda koje su, s jedne strane, pouzdane i tačne, ali istovremeno,
jednostavne i brze. Screening testovi radi procene ukupne alfa/beta aktivnosti u
uzorcima voda, jedna su od često primenjenih tehnika tečne scintilacione
spektroskopije, kojima se efikasno može utvrditi da li uzorak zahteva dalju radiološku
analizu ili ne. U radu je predstavljena optimizacija brze direktne metode za ispitivanje
ukupne alfa/beta aktivnosti u vodama, uz prikaz i diskusiju postignutih granica
detekcije. Ova metoda je modifikacija standardne test metode ASTM D 7283-06 za
ispitivanje ukupne alfa i beta aktivnosti i podrazumeva direktno mešanje uzorka vode sa
scintilacionim koktelom. Na taj način, uzorak je spreman za merenje bez prethodne
pripreme koja, prema standardnim metodama, obično podrazumeva duge procedure
poput uparavanja do suvog ostatka. Optimizacija metode sastoji se u određivanju
optimalnog odnosa uzorak: scintilacioni koktel na osnovu granica detekcije (MDA) u
alfa i beta kanalima, kao i nivoa prigušenja u uzorcima, uzimajući u obzir i maksimalni
kapacitet određenog koktela. Podešena je vrednost PSA (Pulse Shape Analysis)
diskriminatora u cilju optimalne separacije alfa i beta spektara i redukcije pozadinskih
efekata. Kalibracija i validacija metode je izvršena standardnim referentnim materijalima, rastvorima 241Am i 90Sr/90Y. Utvrđeno je da za 300 minuta merenja tečnim
scintilacionim brojačem, mogu se izmeriti koncentracije aktivnosti koje premašuju
vrednosti MDAα=0,294(11) Bq l-1 i MDAβ=0,405(5) Bq l-1 u alfa i beta kanalima,
respektivno. Rezultati validacije metode pokazuju da maksimalna relativna odstupanja
mogu iznositi do 40%, što je prihvatljivo, uzimajući u obzir da metod nije predviđen za
precizno merenje koncentracija aktivnosti pojedinih radionuklida, već za celokupnu
procenu radiološke bezbednosti uzoraka voda.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 29. симпозијум ДЗЗСЦГ : зборник радова
T1  - Rapid LSC method for direct alpha/beta measurements in waters
T1  - Direktna metoda za određivanje ukupne alfa/beta aktivnosti u vodama
SP  - 537
EP  - 543
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8326
ER  - 
@conference{
author = "Stojković, Ivana and Todorović, Nataša and Nikolov, Jovana and Tenjović, Branislava",
year = "2017",
abstract = "Monitoring of environmental samples, drinking and surface waters, is continuously
carried out, demanding development of methods that are both reliable and accurate on
one side, but as simple and fast as possible, on the other. Screening tests such as gross
alpha/beta activity measurements in water samples are one liquid scintillation counting
(LSC) technique widely used as an efficient tool for radiological assesment and
estimation whether water sample needs further analysis or not. In this paper,
establishment of rapid gross alpha/beta screening technique in waters has been
presented, which assumes modification of conventional ASTM D 7283-06 method, since
samples were directly mixed with liquid scintillation cocktail, without any sample
pretreatment. Method’s optimization involved sample-to-cocktail ratio determination
based on the achieved detection limit and sample’s quench level. Optimal value of Pulse
Shape Analysis (PSA) discriminator that considerably improves performance of LSC
technique through alpha/beta spectra separation during radiological quality
measurements of drinking waters has also been investigated. Results of calibration
experiments and method’s validity measurements on spiked samples with 241Am and
90Sr/90Y aqueous standards are presented. Achieved detection limits for 300 minutes
of counting are MDAα=0.294(11) Bq l-1 and MDAβ=0.405(5) Bq l-1, in alpha and beta
window, respectively. Direct alpha/beta method provides deviations up to 40% from
reference values, but it offers advantages over conventional alpha/beta measurements,
it is ultra fast, simple and inexpensive test for efficient screening of water samples., Rutinski monitoring pijaćih i površinskih voda sprovodi se kontinuirano i nameće
potrebu za razvojem metoda koje su, s jedne strane, pouzdane i tačne, ali istovremeno,
jednostavne i brze. Screening testovi radi procene ukupne alfa/beta aktivnosti u
uzorcima voda, jedna su od često primenjenih tehnika tečne scintilacione
spektroskopije, kojima se efikasno može utvrditi da li uzorak zahteva dalju radiološku
analizu ili ne. U radu je predstavljena optimizacija brze direktne metode za ispitivanje
ukupne alfa/beta aktivnosti u vodama, uz prikaz i diskusiju postignutih granica
detekcije. Ova metoda je modifikacija standardne test metode ASTM D 7283-06 za
ispitivanje ukupne alfa i beta aktivnosti i podrazumeva direktno mešanje uzorka vode sa
scintilacionim koktelom. Na taj način, uzorak je spreman za merenje bez prethodne
pripreme koja, prema standardnim metodama, obično podrazumeva duge procedure
poput uparavanja do suvog ostatka. Optimizacija metode sastoji se u određivanju
optimalnog odnosa uzorak: scintilacioni koktel na osnovu granica detekcije (MDA) u
alfa i beta kanalima, kao i nivoa prigušenja u uzorcima, uzimajući u obzir i maksimalni
kapacitet određenog koktela. Podešena je vrednost PSA (Pulse Shape Analysis)
diskriminatora u cilju optimalne separacije alfa i beta spektara i redukcije pozadinskih
efekata. Kalibracija i validacija metode je izvršena standardnim referentnim materijalima, rastvorima 241Am i 90Sr/90Y. Utvrđeno je da za 300 minuta merenja tečnim
scintilacionim brojačem, mogu se izmeriti koncentracije aktivnosti koje premašuju
vrednosti MDAα=0,294(11) Bq l-1 i MDAβ=0,405(5) Bq l-1 u alfa i beta kanalima,
respektivno. Rezultati validacije metode pokazuju da maksimalna relativna odstupanja
mogu iznositi do 40%, što je prihvatljivo, uzimajući u obzir da metod nije predviđen za
precizno merenje koncentracija aktivnosti pojedinih radionuklida, već za celokupnu
procenu radiološke bezbednosti uzoraka voda.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "29. симпозијум ДЗЗСЦГ : зборник радова",
title = "Rapid LSC method for direct alpha/beta measurements in waters, Direktna metoda za određivanje ukupne alfa/beta aktivnosti u vodama",
pages = "537-543",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8326"
}
Stojković, I., Todorović, N., Nikolov, J.,& Tenjović, B.. (2017). Rapid LSC method for direct alpha/beta measurements in waters. in 29. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 537-543.
https://hdl.handle.net/21.15107/rcub_vinar_8326
Stojković I, Todorović N, Nikolov J, Tenjović B. Rapid LSC method for direct alpha/beta measurements in waters. in 29. симпозијум ДЗЗСЦГ : зборник радова. 2017;:537-543.
https://hdl.handle.net/21.15107/rcub_vinar_8326 .
Stojković, Ivana, Todorović, Nataša, Nikolov, Jovana, Tenjović, Branislava, "Rapid LSC method for direct alpha/beta measurements in waters" in 29. симпозијум ДЗЗСЦГ : зборник радова (2017):537-543,
https://hdl.handle.net/21.15107/rcub_vinar_8326 .