@conference{
author = "Popeskov, B. and Milivojevic, M. and Cvetic, J. and Nedeljkovic, T. and Draganic, I.",
year = "2007",
abstract = "In order to determine position, dimensions and intensities of multiply charged ion beams at the mVINIS Ion Source, a novel method was developed based on a fluorescent screen and a commercial digital TV camera. The spatial characteristics of multiply charged ion beams (for example the ionization states of Ar (2+) to Ar10+) have been precisely measured and analyzed at the TESLA Accelerator Installation for the first time. In this work, we discuss in details the characteristics of Ar (8+) ion beams. The obtained ion beam characteristics were compared with the results of previously applied conventional methods of ion beam diagnostics.",
journal = "Journal of Physics: Conference Series",
title = "Highly charged ion beam diagnostics at the mVINIS Ion Source",
volume = "58",
pages = "423-+",
doi = "10.1088/1742-6596/58/1/097"
}