Dobrijević, R.

Link to this page

Authority KeyName Variants
b2727618-f524-4891-abaa-37b1a2caddbd
  • Dobrijević, R. (2)
Projects
No records found.

Author's Bibliography

Development of 90Sr/90Y generator using electrochemical separation

Petrović, Đorđe; Đokić, Divna Đ.; Dobrijević, R.; Stanković, Dragana; Glodić, Pavle

(Society of Physical Chemists of Serbia, 2010)

TY  - CONF
AU  - Petrović, Đorđe
AU  - Đokić, Divna Đ.
AU  - Dobrijević, R.
AU  - Stanković, Dragana
AU  - Glodić, Pavle
PY  - 2010
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9298
AB  - Using of radiopharmaceuticals based on 90Y in the treatment of solid cancer is
increasing in recent years. Therefore, generators have been developed for obtaining
the 90Y using a feature of 90Sr for spontaneous breakthrough and its equilibrium
with 90Y. Electrochemical separation of 90Y from 90Sr has become the basic method
for obtaining 90Y in high radiochemical yield. For the preliminary study, we used
the electrochemical system with two electrochemical cells. Quality control was
performed using extraction paper chromatography (EPC). Preliminary results
showed that the separation completed successfully in both ways, quantity and
quality.
PB  - Society of Physical Chemists of Serbia
C3  - Physical chemistry 2010 : 10th international conference on fundamental and applied aspects of physical chemistry
T1  - Development of 90Sr/90Y generator using electrochemical separation
UR  - https://hdl.handle.net/21.15107/rcub_vinar_9298
ER  - 
@conference{
author = "Petrović, Đorđe and Đokić, Divna Đ. and Dobrijević, R. and Stanković, Dragana and Glodić, Pavle",
year = "2010",
abstract = "Using of radiopharmaceuticals based on 90Y in the treatment of solid cancer is
increasing in recent years. Therefore, generators have been developed for obtaining
the 90Y using a feature of 90Sr for spontaneous breakthrough and its equilibrium
with 90Y. Electrochemical separation of 90Y from 90Sr has become the basic method
for obtaining 90Y in high radiochemical yield. For the preliminary study, we used
the electrochemical system with two electrochemical cells. Quality control was
performed using extraction paper chromatography (EPC). Preliminary results
showed that the separation completed successfully in both ways, quantity and
quality.",
publisher = "Society of Physical Chemists of Serbia",
journal = "Physical chemistry 2010 : 10th international conference on fundamental and applied aspects of physical chemistry",
title = "Development of 90Sr/90Y generator using electrochemical separation",
url = "https://hdl.handle.net/21.15107/rcub_vinar_9298"
}
Petrović, Đ., Đokić, D. Đ., Dobrijević, R., Stanković, D.,& Glodić, P.. (2010). Development of 90Sr/90Y generator using electrochemical separation. in Physical chemistry 2010 : 10th international conference on fundamental and applied aspects of physical chemistry
Society of Physical Chemists of Serbia..
https://hdl.handle.net/21.15107/rcub_vinar_9298
Petrović Đ, Đokić DĐ, Dobrijević R, Stanković D, Glodić P. Development of 90Sr/90Y generator using electrochemical separation. in Physical chemistry 2010 : 10th international conference on fundamental and applied aspects of physical chemistry. 2010;.
https://hdl.handle.net/21.15107/rcub_vinar_9298 .
Petrović, Đorđe, Đokić, Divna Đ., Dobrijević, R., Stanković, Dragana, Glodić, Pavle, "Development of 90Sr/90Y generator using electrochemical separation" in Physical chemistry 2010 : 10th international conference on fundamental and applied aspects of physical chemistry (2010),
https://hdl.handle.net/21.15107/rcub_vinar_9298 .

Radiografski uređaji Gammamat SE i Gammavolt SU 50 sa izvorom 75 SE i zaštita od zračenja

Petrović, Đorđe; Dobrijević, R.; Čašić, Đ.

(Beograd : Savez mašinskih i elektrotehničkih inženjera i tehničara Srbije (SMEITS) : Društvo za procesnu tehniku, 2010)

TY  - CONF
AU  - Petrović, Đorđe
AU  - Dobrijević, R.
AU  - Čašić, Đ.
PY  - 2010
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11619
AB  - Zatvoreni radioaktivni izvor 75Se se sve više koristi u radiografskim kontrolama kompaktnosti materijala. Njegova energija γ-zračenja odgovara za kontrolu npr. čeličnih materijala debljine 5–30 mm. Za korišćenje ovih izvora služi uređaj novije generacije Gammamat SE. Međutim za radiografska ispitivanja sa 75Se može se koristiti i uređaj Gammavolt SU 50 ili Gammavolt SU 100 koji su od strane proizvođača namenjeni za korišćenje izvora 192Ir. U ovom radu su prikazani rezultati dozimetrijskih merenja koja se odnose na radiografske uređaje Gammamat SE i Gammavolt SU 50 u koje je ugrađen radioaktivni izvor 75Se aktivnosti 3TBq. Prikazane su prednosti i mane svakog uređaja sa aspekta eksploatacije u svakodnevnom radu i sa aspekta  zaštite od zračenja.
AB  - The closed radioactive source 75Se is increasingly used in radiographic controls of material compactness. Its radiation energy is suitable for control of steel materials of 5–30mm thickness.  The new generation device Gammamat SE serves for the use of these sources. However, for radiographic testing with 75Se Gammavolt SU 50 or Gammavolt SU 100 may be used, although, according to their manufacturer,   they should serve for using  192Ir source.  This paper presents the results of dosimetric measurements relating to radiographic devices Gammamat SE and Gammavolt SU 50, with 75Se  radioactive source with 3TBq activity. Advantages and disadvantages of each device were given from the aspect of exploitation in daily work and from the aspect of  radiation protection.
PB  - Beograd : Savez mašinskih i elektrotehničkih inženjera i tehničara Srbije (SMEITS) : Društvo za procesnu tehniku
C3  - 23. Međunarodni kongres o procesnoj industriji - PROCESING ′10 : zbornik radova
T1  - Radiografski uređaji Gammamat SE i Gammavolt SU 50 sa izvorom 75 SE i zaštita od zračenja
T1  - Radiographic devices grammat se  and gammavolt SU 50 with source 75SE  and radiation protection
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11619
ER  - 
@conference{
author = "Petrović, Đorđe and Dobrijević, R. and Čašić, Đ.",
year = "2010",
abstract = "Zatvoreni radioaktivni izvor 75Se se sve više koristi u radiografskim kontrolama kompaktnosti materijala. Njegova energija γ-zračenja odgovara za kontrolu npr. čeličnih materijala debljine 5–30 mm. Za korišćenje ovih izvora služi uređaj novije generacije Gammamat SE. Međutim za radiografska ispitivanja sa 75Se može se koristiti i uređaj Gammavolt SU 50 ili Gammavolt SU 100 koji su od strane proizvođača namenjeni za korišćenje izvora 192Ir. U ovom radu su prikazani rezultati dozimetrijskih merenja koja se odnose na radiografske uređaje Gammamat SE i Gammavolt SU 50 u koje je ugrađen radioaktivni izvor 75Se aktivnosti 3TBq. Prikazane su prednosti i mane svakog uređaja sa aspekta eksploatacije u svakodnevnom radu i sa aspekta  zaštite od zračenja., The closed radioactive source 75Se is increasingly used in radiographic controls of material compactness. Its radiation energy is suitable for control of steel materials of 5–30mm thickness.  The new generation device Gammamat SE serves for the use of these sources. However, for radiographic testing with 75Se Gammavolt SU 50 or Gammavolt SU 100 may be used, although, according to their manufacturer,   they should serve for using  192Ir source.  This paper presents the results of dosimetric measurements relating to radiographic devices Gammamat SE and Gammavolt SU 50, with 75Se  radioactive source with 3TBq activity. Advantages and disadvantages of each device were given from the aspect of exploitation in daily work and from the aspect of  radiation protection.",
publisher = "Beograd : Savez mašinskih i elektrotehničkih inženjera i tehničara Srbije (SMEITS) : Društvo za procesnu tehniku",
journal = "23. Međunarodni kongres o procesnoj industriji - PROCESING ′10 : zbornik radova",
title = "Radiografski uređaji Gammamat SE i Gammavolt SU 50 sa izvorom 75 SE i zaštita od zračenja, Radiographic devices grammat se  and gammavolt SU 50 with source 75SE  and radiation protection",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11619"
}
Petrović, Đ., Dobrijević, R.,& Čašić, Đ.. (2010). Radiografski uređaji Gammamat SE i Gammavolt SU 50 sa izvorom 75 SE i zaštita od zračenja. in 23. Međunarodni kongres o procesnoj industriji - PROCESING ′10 : zbornik radova
Beograd : Savez mašinskih i elektrotehničkih inženjera i tehničara Srbije (SMEITS) : Društvo za procesnu tehniku..
https://hdl.handle.net/21.15107/rcub_vinar_11619
Petrović Đ, Dobrijević R, Čašić Đ. Radiografski uređaji Gammamat SE i Gammavolt SU 50 sa izvorom 75 SE i zaštita od zračenja. in 23. Međunarodni kongres o procesnoj industriji - PROCESING ′10 : zbornik radova. 2010;.
https://hdl.handle.net/21.15107/rcub_vinar_11619 .
Petrović, Đorđe, Dobrijević, R., Čašić, Đ., "Radiografski uređaji Gammamat SE i Gammavolt SU 50 sa izvorom 75 SE i zaštita od zračenja" in 23. Međunarodni kongres o procesnoj industriji - PROCESING ′10 : zbornik radova (2010),
https://hdl.handle.net/21.15107/rcub_vinar_11619 .