Evaluation of radiation dose for patients undergoing mammography in Qatar

AlNaemi, Huda; Aly, Antar; J Omar, Ahmed; AlObadli, Amal; Ciraj-Bjelac, Olivera; Kharita, Mohamad Hassan; Rehani, Madan M

(2020)

TY  - JOUR
AU  - AlNaemi, Huda
AU  - Aly, Antar
AU  - J Omar, Ahmed
AU  - AlObadli, Amal
AU  - Ciraj-Bjelac, Olivera
AU  - Kharita, Mohamad Hassan
AU  - Rehani, Madan M
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9102
AB  - In the absence of information on radiation doses in mammography in the Gulf countries, this study was designed to assess patient dose in terms of entrance surface air kerma and average glandular dose (AGD) in three mammography units in Qatar that covers 21% of all mammography systems in the country. The study of 150 patients involving 600 projections indicated that the average value of AGD in patients was 2.2 mGy for cranio-caudal and 2.5 mGy for mediolateral-oblique views, respectively. Dose assessment was also performed for polymethyl methacrylate phantoms of thicknesses, ranging from 20 to 80 mm. Comparing the patient dose values with several other publications in literature for full-field digital mammography, our values are typically higher, which can be likely attributed to the larger compressed breast thickness.
T2  - Radiation Protection Dosimetry
T1  - Evaluation of radiation dose for patients undergoing mammography in Qatar
VL  - 189
IS  - 3
SP  - 354
EP  - 361
DO  - 10.1093/rpd/ncaa049
ER  - 
@article{
author = "AlNaemi, Huda and Aly, Antar and J Omar, Ahmed and AlObadli, Amal and Ciraj-Bjelac, Olivera and Kharita, Mohamad Hassan and Rehani, Madan M",
year = "2020",
abstract = "In the absence of information on radiation doses in mammography in the Gulf countries, this study was designed to assess patient dose in terms of entrance surface air kerma and average glandular dose (AGD) in three mammography units in Qatar that covers 21% of all mammography systems in the country. The study of 150 patients involving 600 projections indicated that the average value of AGD in patients was 2.2 mGy for cranio-caudal and 2.5 mGy for mediolateral-oblique views, respectively. Dose assessment was also performed for polymethyl methacrylate phantoms of thicknesses, ranging from 20 to 80 mm. Comparing the patient dose values with several other publications in literature for full-field digital mammography, our values are typically higher, which can be likely attributed to the larger compressed breast thickness.",
journal = "Radiation Protection Dosimetry",
title = "Evaluation of radiation dose for patients undergoing mammography in Qatar",
volume = "189",
number = "3",
pages = "354-361",
doi = "10.1093/rpd/ncaa049"
}
AlNaemi, H., Aly, A., J Omar, A., AlObadli, A., Ciraj-Bjelac, O., Kharita, M. H.,& Rehani, M. M.. (2020). Evaluation of radiation dose for patients undergoing mammography in Qatar. in Radiation Protection Dosimetry, 189(3), 354-361.
https://doi.org/10.1093/rpd/ncaa049
AlNaemi H, Aly A, J Omar A, AlObadli A, Ciraj-Bjelac O, Kharita MH, Rehani MM. Evaluation of radiation dose for patients undergoing mammography in Qatar. in Radiation Protection Dosimetry. 2020;189(3):354-361.
doi:10.1093/rpd/ncaa049 .
AlNaemi, Huda, Aly, Antar, J Omar, Ahmed, AlObadli, Amal, Ciraj-Bjelac, Olivera, Kharita, Mohamad Hassan, Rehani, Madan M, "Evaluation of radiation dose for patients undergoing mammography in Qatar" in Radiation Protection Dosimetry, 189, no. 3 (2020):354-361,
https://doi.org/10.1093/rpd/ncaa049 . .