Cuplić, Valentina

Link to this page

Authority KeyName Variants
d69fea6c-19f2-4a17-9d01-42266f493131
  • Cuplić, Valentina (1)
Projects

Author's Bibliography

Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications

Stanković, Dalibor M.; Ognjanović, Miloš; Jović, Milica; Cuplić, Valentina; Lesch, Andreas; Girault, Hubert H.; Gavrović-Jankulović, Marija; Antić, Bratislav

(2019)

TY  - JOUR
AU  - Stanković, Dalibor M.
AU  - Ognjanović, Miloš
AU  - Jović, Milica
AU  - Cuplić, Valentina
AU  - Lesch, Andreas
AU  - Girault, Hubert H.
AU  - Gavrović-Jankulović, Marija
AU  - Antić, Bratislav
PY  - 2019
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8342
AB  - A disposable acetaminophen biosensor based on inkjet-printed CNT electrodes (IJPCNT) modified with amidase/cerium dioxide@graphene nanoribbons composite was developed (ACeO2@GNR/IJPCNT). The enzyme amidase A was used for the first time as a recognition element. Inkjet-printed CNT electrodes served as a basis for the construction of a biosensor that enables droplet detection using 5 μL sample volume. The biosensor showed high selectivity, sensitivity, a low detection limit of 0.18 μM and a wide working linear range from 1 to 100 μM. The proposed approach allows fast and reliable detection of acetaminophen in biological fluids with negligible matrix effect and remarkable reproducibility. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
T2  - Electroanalysis
T1  - Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications
VL  - 31
IS  - 8
SP  - 1517
EP  - 1525
DO  - 10.1002/elan.201900129
ER  - 
@article{
author = "Stanković, Dalibor M. and Ognjanović, Miloš and Jović, Milica and Cuplić, Valentina and Lesch, Andreas and Girault, Hubert H. and Gavrović-Jankulović, Marija and Antić, Bratislav",
year = "2019",
abstract = "A disposable acetaminophen biosensor based on inkjet-printed CNT electrodes (IJPCNT) modified with amidase/cerium dioxide@graphene nanoribbons composite was developed (ACeO2@GNR/IJPCNT). The enzyme amidase A was used for the first time as a recognition element. Inkjet-printed CNT electrodes served as a basis for the construction of a biosensor that enables droplet detection using 5 μL sample volume. The biosensor showed high selectivity, sensitivity, a low detection limit of 0.18 μM and a wide working linear range from 1 to 100 μM. The proposed approach allows fast and reliable detection of acetaminophen in biological fluids with negligible matrix effect and remarkable reproducibility. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim",
journal = "Electroanalysis",
title = "Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications",
volume = "31",
number = "8",
pages = "1517-1525",
doi = "10.1002/elan.201900129"
}
Stanković, D. M., Ognjanović, M., Jović, M., Cuplić, V., Lesch, A., Girault, H. H., Gavrović-Jankulović, M.,& Antić, B.. (2019). Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications. in Electroanalysis, 31(8), 1517-1525.
https://doi.org/10.1002/elan.201900129
Stanković DM, Ognjanović M, Jović M, Cuplić V, Lesch A, Girault HH, Gavrović-Jankulović M, Antić B. Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications. in Electroanalysis. 2019;31(8):1517-1525.
doi:10.1002/elan.201900129 .
Stanković, Dalibor M., Ognjanović, Miloš, Jović, Milica, Cuplić, Valentina, Lesch, Andreas, Girault, Hubert H., Gavrović-Jankulović, Marija, Antić, Bratislav, "Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications" in Electroanalysis, 31, no. 8 (2019):1517-1525,
https://doi.org/10.1002/elan.201900129 . .
12
7
11