Vidojković, Sonja M.

Link to this page

Authority KeyName Variants
b8c2172f-179f-4ba2-b564-27902d35f217
  • Vidojković, Sonja M. (1)
Projects

Author's Bibliography

Economizer water-wall damages initiated by feedwater impurities

Vidojković, Sonja M.; Onjia, Antonije E.; Devečerski, Aleksandar; Grahovac, Nebojša N.; Nastasović, Aleksandra B.

(2014)

TY  - JOUR
AU  - Vidojković, Sonja M.
AU  - Onjia, Antonije E.
AU  - Devečerski, Aleksandar
AU  - Grahovac, Nebojša N.
AU  - Nastasović, Aleksandra B.
PY  - 2014
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/294
AB  - The main causes of efficiency loss in thermal power plants are boiler tube failures that diminish unit reliability and availability, and raise the cost of the electric energy. For that reason, the regular examination of boiler tubes is indispensable measure for prevention of future malfunctions of power units. The microscopic examination of economizers inner wall microstructure, the analysis of chemical composition of deposit using X-ray diffraction (XRD) and scanning electron microscopy/energy dispersive spectroscopy (SEM/EDS) have been performed in a subcritical power plant. Stress corrosion cracking, pitting corrosion, destroyed protective magnetite layer, presence of magnetite and hematite in deposit and corrosive impurities within the cracks have indicated the effect of inadequate quality of feedwater that cannot entirely ensure reliable operation of the boiler. It may be stated that maintenance of present boiler does not provide its reliable operation. The extensive chemical control of water/steam cycle was recommended.
T2  - Hemijska industrija
T1  - Economizer water-wall damages initiated by feedwater impurities
VL  - 68
IS  - 5
SP  - 559
EP  - 563
DO  - 10.2298/HEMIND130715082V
ER  - 
@article{
author = "Vidojković, Sonja M. and Onjia, Antonije E. and Devečerski, Aleksandar and Grahovac, Nebojša N. and Nastasović, Aleksandra B.",
year = "2014",
abstract = "The main causes of efficiency loss in thermal power plants are boiler tube failures that diminish unit reliability and availability, and raise the cost of the electric energy. For that reason, the regular examination of boiler tubes is indispensable measure for prevention of future malfunctions of power units. The microscopic examination of economizers inner wall microstructure, the analysis of chemical composition of deposit using X-ray diffraction (XRD) and scanning electron microscopy/energy dispersive spectroscopy (SEM/EDS) have been performed in a subcritical power plant. Stress corrosion cracking, pitting corrosion, destroyed protective magnetite layer, presence of magnetite and hematite in deposit and corrosive impurities within the cracks have indicated the effect of inadequate quality of feedwater that cannot entirely ensure reliable operation of the boiler. It may be stated that maintenance of present boiler does not provide its reliable operation. The extensive chemical control of water/steam cycle was recommended.",
journal = "Hemijska industrija",
title = "Economizer water-wall damages initiated by feedwater impurities",
volume = "68",
number = "5",
pages = "559-563",
doi = "10.2298/HEMIND130715082V"
}
Vidojković, S. M., Onjia, A. E., Devečerski, A., Grahovac, N. N.,& Nastasović, A. B.. (2014). Economizer water-wall damages initiated by feedwater impurities. in Hemijska industrija, 68(5), 559-563.
https://doi.org/10.2298/HEMIND130715082V
Vidojković SM, Onjia AE, Devečerski A, Grahovac NN, Nastasović AB. Economizer water-wall damages initiated by feedwater impurities. in Hemijska industrija. 2014;68(5):559-563.
doi:10.2298/HEMIND130715082V .
Vidojković, Sonja M., Onjia, Antonije E., Devečerski, Aleksandar, Grahovac, Nebojša N., Nastasović, Aleksandra B., "Economizer water-wall damages initiated by feedwater impurities" in Hemijska industrija, 68, no. 5 (2014):559-563,
https://doi.org/10.2298/HEMIND130715082V . .
4
3
4