D’Elia, Gerardo

Link to this page

Authority KeyName Variants
83428f68-93c2-4c15-88e1-15fbb076c6c1
  • D’Elia, Gerardo (1)
Projects
No records found.

Author's Bibliography

A Global Multi-Unit Calibration as a Method for Large Scale IoT Particulate Matter Monitoring Systems Deployments

De Vito, Saverio; D’Elia, Gerardo; Ferlito, Sergio; Di Francia, Girolamo; Davidović, Miloš; Kleut, Duška; Stojanović, Danka; Jovašević-Stojanović, Milena

(2023)

TY  - JOUR
AU  - De Vito, Saverio
AU  - D’Elia, Gerardo
AU  - Ferlito, Sergio
AU  - Di Francia, Girolamo
AU  - Davidović, Miloš
AU  - Kleut, Duška
AU  - Stojanović, Danka
AU  - Jovašević-Stojanović, Milena
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12046
AB  - Scalable and effective calibration is a fundamental requirement for Low Cost Air Quality Monitoring Systems and will enable accurate and pervasive monitoring in cities. Suffering from environmental interferences and fabrication variance, these devices need to encompass sensors specific and complex calibration processes for reaching a sufficient accuracy to be deployed as indicative measurement devices in Air Quality (AQ) monitoring networks. Concept and sensor drift often force calibration process to be frequently repeated. These issues lead to unbearable calibration costs which denies their massive deployment when accuracy is a concern. In this work, We propose a zero transfer samples, global calibration methodology as a technological enabler for IoT AQ multisensory devices which relies on low cost Particulate Matter (PM) sensors. This methodology is based on field recorded responses from a limited number of IoT AQ multisensors units and machine learning concepts and can be universally applied to all units of the same type. A multi season test campaign shown that, when applied to different sensors, this methodology performances match those of state of the art methodology which requires to derive different calibration parameters for each different unit. If confirmed, these results show that, when properly derived, a global calibration law can be exploited for a large number of networked devices with dramatic cost reduction eventually allowing massive deployment of accurate IoT AQ monitoring devices. Furthermore, this calibration model could be easily embedded on board of the device or implemented on the edge allowing immediate access to accurate readings for personal exposure monitor applications as well as reducing long range data transfer needs.
T2  - IEEE Transactions on Instrumentation and Measurement
T1  - A Global Multi-Unit Calibration as a Method for Large Scale IoT Particulate Matter Monitoring Systems Deployments
SP  - 1
EP  - 1
DO  - 10.1109/TIM.2023.3331428
ER  - 
@article{
author = "De Vito, Saverio and D’Elia, Gerardo and Ferlito, Sergio and Di Francia, Girolamo and Davidović, Miloš and Kleut, Duška and Stojanović, Danka and Jovašević-Stojanović, Milena",
year = "2023",
abstract = "Scalable and effective calibration is a fundamental requirement for Low Cost Air Quality Monitoring Systems and will enable accurate and pervasive monitoring in cities. Suffering from environmental interferences and fabrication variance, these devices need to encompass sensors specific and complex calibration processes for reaching a sufficient accuracy to be deployed as indicative measurement devices in Air Quality (AQ) monitoring networks. Concept and sensor drift often force calibration process to be frequently repeated. These issues lead to unbearable calibration costs which denies their massive deployment when accuracy is a concern. In this work, We propose a zero transfer samples, global calibration methodology as a technological enabler for IoT AQ multisensory devices which relies on low cost Particulate Matter (PM) sensors. This methodology is based on field recorded responses from a limited number of IoT AQ multisensors units and machine learning concepts and can be universally applied to all units of the same type. A multi season test campaign shown that, when applied to different sensors, this methodology performances match those of state of the art methodology which requires to derive different calibration parameters for each different unit. If confirmed, these results show that, when properly derived, a global calibration law can be exploited for a large number of networked devices with dramatic cost reduction eventually allowing massive deployment of accurate IoT AQ monitoring devices. Furthermore, this calibration model could be easily embedded on board of the device or implemented on the edge allowing immediate access to accurate readings for personal exposure monitor applications as well as reducing long range data transfer needs.",
journal = "IEEE Transactions on Instrumentation and Measurement",
title = "A Global Multi-Unit Calibration as a Method for Large Scale IoT Particulate Matter Monitoring Systems Deployments",
pages = "1-1",
doi = "10.1109/TIM.2023.3331428"
}
De Vito, S., D’Elia, G., Ferlito, S., Di Francia, G., Davidović, M., Kleut, D., Stojanović, D.,& Jovašević-Stojanović, M.. (2023). A Global Multi-Unit Calibration as a Method for Large Scale IoT Particulate Matter Monitoring Systems Deployments. in IEEE Transactions on Instrumentation and Measurement, 1-1.
https://doi.org/10.1109/TIM.2023.3331428
De Vito S, D’Elia G, Ferlito S, Di Francia G, Davidović M, Kleut D, Stojanović D, Jovašević-Stojanović M. A Global Multi-Unit Calibration as a Method for Large Scale IoT Particulate Matter Monitoring Systems Deployments. in IEEE Transactions on Instrumentation and Measurement. 2023;:1-1.
doi:10.1109/TIM.2023.3331428 .
De Vito, Saverio, D’Elia, Gerardo, Ferlito, Sergio, Di Francia, Girolamo, Davidović, Miloš, Kleut, Duška, Stojanović, Danka, Jovašević-Stojanović, Milena, "A Global Multi-Unit Calibration as a Method for Large Scale IoT Particulate Matter Monitoring Systems Deployments" in IEEE Transactions on Instrumentation and Measurement (2023):1-1,
https://doi.org/10.1109/TIM.2023.3331428 . .
1
1
1