Improving standardization in radiation protection dosimetry and supporting reference laboratories in the European Partnership Project GuideRadPROS

Ketelhut, Steffen; Zutz, Hayo; Hupe, Oliver; Siiskonen, Teemu; Boziari, Argiro; Živanović, Miloš; Kržanović, Nikola; Van Hoey, Olivier; Šabeta, Amra

(2023)

TY  - CONF
AU  - Ketelhut, Steffen
AU  - Zutz, Hayo
AU  - Hupe, Oliver
AU  - Siiskonen, Teemu
AU  - Boziari, Argiro
AU  - Živanović, Miloš
AU  - Kržanović, Nikola
AU  - Van Hoey, Olivier
AU  - Šabeta, Amra
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11951
AB  - Introduction
Calibration laboratories and industrial enterprises involved in radiation protection dosimetry face significant
challenges following the recent update of the ISO 4037 in conjunction with the new radiation protection
quantities introduced in ICRU Report 95, the gaps and contradictions in the standards that set photon
dosimeter requirements, and the lack of standards for upcoming and new technologies.
Methods
The European Partnership Project 23NRM07 GuideRadPROS launched in June 2023 will address these issues
over the next three years. The project objectives are:
1. to develop harmonized X-ray spectrometry in accordance with the ISO 4037 standard series, evaluate
discrepancies between measured and calculated half value layer of X-ray spectra, and produce data to update
requirements for reference fields.
2. to develop guidance and training material for the calibration of dosimeters.
3. to produce guidance on validated procedures for harmonized type testing based on IEC standards.
4. to investigate new and upcoming technologies and assess future standardization needs and to produce a
guidance document for the implementation of the new operational quantities of ICRU Report 95 into standards
and regulations.
5. to collaborate with ISO and IEC and users of their dosimetry standards to ensure that project outputs align
with their needs.
Results and Conclusions
GuideRadPROS will improve the confidence in radiation protection dosimetry, both by promoting the
implementation of the ISO 4037 standard series and by assessing the impact of the operational quantities of
the ICRU Report 95 on daily measurements in radiation protection. Furthermore, the outcome of this project will
lead to improved and comparable procedures in calibration and type testing within Europe
C3  - ICDA-4 : 4th International Conference on Dosimetry and its Applications : Book of abstracts
T1  - Improving standardization in radiation protection dosimetry and supporting reference laboratories in the European Partnership Project GuideRadPROS
SP  - 203
EP  - 203
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11951
ER  - 
@conference{
author = "Ketelhut, Steffen and Zutz, Hayo and Hupe, Oliver and Siiskonen, Teemu and Boziari, Argiro and Živanović, Miloš and Kržanović, Nikola and Van Hoey, Olivier and Šabeta, Amra",
year = "2023",
abstract = "Introduction
Calibration laboratories and industrial enterprises involved in radiation protection dosimetry face significant
challenges following the recent update of the ISO 4037 in conjunction with the new radiation protection
quantities introduced in ICRU Report 95, the gaps and contradictions in the standards that set photon
dosimeter requirements, and the lack of standards for upcoming and new technologies.
Methods
The European Partnership Project 23NRM07 GuideRadPROS launched in June 2023 will address these issues
over the next three years. The project objectives are:
1. to develop harmonized X-ray spectrometry in accordance with the ISO 4037 standard series, evaluate
discrepancies between measured and calculated half value layer of X-ray spectra, and produce data to update
requirements for reference fields.
2. to develop guidance and training material for the calibration of dosimeters.
3. to produce guidance on validated procedures for harmonized type testing based on IEC standards.
4. to investigate new and upcoming technologies and assess future standardization needs and to produce a
guidance document for the implementation of the new operational quantities of ICRU Report 95 into standards
and regulations.
5. to collaborate with ISO and IEC and users of their dosimetry standards to ensure that project outputs align
with their needs.
Results and Conclusions
GuideRadPROS will improve the confidence in radiation protection dosimetry, both by promoting the
implementation of the ISO 4037 standard series and by assessing the impact of the operational quantities of
the ICRU Report 95 on daily measurements in radiation protection. Furthermore, the outcome of this project will
lead to improved and comparable procedures in calibration and type testing within Europe",
journal = "ICDA-4 : 4th International Conference on Dosimetry and its Applications : Book of abstracts",
title = "Improving standardization in radiation protection dosimetry and supporting reference laboratories in the European Partnership Project GuideRadPROS",
pages = "203-203",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11951"
}
Ketelhut, S., Zutz, H., Hupe, O., Siiskonen, T., Boziari, A., Živanović, M., Kržanović, N., Van Hoey, O.,& Šabeta, A.. (2023). Improving standardization in radiation protection dosimetry and supporting reference laboratories in the European Partnership Project GuideRadPROS. in ICDA-4 : 4th International Conference on Dosimetry and its Applications : Book of abstracts, 203-203.
https://hdl.handle.net/21.15107/rcub_vinar_11951
Ketelhut S, Zutz H, Hupe O, Siiskonen T, Boziari A, Živanović M, Kržanović N, Van Hoey O, Šabeta A. Improving standardization in radiation protection dosimetry and supporting reference laboratories in the European Partnership Project GuideRadPROS. in ICDA-4 : 4th International Conference on Dosimetry and its Applications : Book of abstracts. 2023;:203-203.
https://hdl.handle.net/21.15107/rcub_vinar_11951 .
Ketelhut, Steffen, Zutz, Hayo, Hupe, Oliver, Siiskonen, Teemu, Boziari, Argiro, Živanović, Miloš, Kržanović, Nikola, Van Hoey, Olivier, Šabeta, Amra, "Improving standardization in radiation protection dosimetry and supporting reference laboratories in the European Partnership Project GuideRadPROS" in ICDA-4 : 4th International Conference on Dosimetry and its Applications : Book of abstracts (2023):203-203,
https://hdl.handle.net/21.15107/rcub_vinar_11951 .

EURAMET i DOSEtrace projekat i dodatna interkomparacija

Živanović, Miloš Z.; Hupe, Oliver; Šabeta, Amra; Kržanović, Nikola; Makarić, Vedrana

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2019)

TY  - CONF
AU  - Živanović, Miloš Z.
AU  - Hupe, Oliver
AU  - Šabeta, Amra
AU  - Kržanović, Nikola
AU  - Makarić, Vedrana
PY  - 2019
UR  - https://plus.sr.cobiss.net/opac7/bib/279687436
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8717
AB  - Tačna i sledljiva merenja operativnih veličina su neophodna za adekvatnu zaštitu od zračenja. Nacionalni metrološki instituti i Imenovani instituti su zaduženi za diseminaciju SI jedinice Sivert i za etaloniranje korisničke opreme. Ipak, u velikom broju Evropskih zemalja, mogušnosti etaloniranjaza operativne veličine su nedovoljno razvijene ili nepostoješe. Glavni cilj DOSEtrace projekta je unapređenje ovih mogućnosti, kao i smanjenje proširene merne nesigurnosti učesnika projekta ispod 5 % (k = 2). U okviru projekta še biti sprovedena Dodatna interkomparacija kalibracionih faktora za ambijentalni dozni ekvivalent. Ova interkomparacija še pomoši učesnicima projekta da validiraju merne mogušnosti razvijene pre i tokom projekta, a takođe će pomoći novim institutima da steknu međunarodno priznanje. U okviru intercomparacije, biše pokriveni kvaliteti zračenja radionuklida, kao i x-zračenja.
AB  - Accurate and traceable measurements of operational quantities are required for adequate radiation protection. National Measurement Institutes (NMI) and Designated Institutes (DI) are responsible for disseminating the SI unit sievert and for calibrating user equipment. However, in many emerging European countries, calibration and measurement capabilities for operational quantities are limited or nonexistent. The main objective of DOSEtrace project is to improve these capabilities and for the participants to achieve the expanded measurement uncertainty of less than5% (k = 2). Within the project, a Supplementary comparison of calibration factors in terms of ambient dose equivalent will be conducted. This comparison will help to validate the capabilities that the partners developed during and before the project and will help emerging institutes gain international recognition. The comparison will cover both radionuclide and x-ray radiation qualities according to ISO 4037-1.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 30. симпозијум ДЗЗСЦГ : зборник радова
T1  - EURAMET i DOSEtrace projekat i dodatna interkomparacija
T1  - EURAMET i DOSEtrace project and supplementary comparison
SP  - 472
EP  - 477
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8717
ER  - 
@conference{
author = "Živanović, Miloš Z. and Hupe, Oliver and Šabeta, Amra and Kržanović, Nikola and Makarić, Vedrana",
year = "2019",
abstract = "Tačna i sledljiva merenja operativnih veličina su neophodna za adekvatnu zaštitu od zračenja. Nacionalni metrološki instituti i Imenovani instituti su zaduženi za diseminaciju SI jedinice Sivert i za etaloniranje korisničke opreme. Ipak, u velikom broju Evropskih zemalja, mogušnosti etaloniranjaza operativne veličine su nedovoljno razvijene ili nepostoješe. Glavni cilj DOSEtrace projekta je unapređenje ovih mogućnosti, kao i smanjenje proširene merne nesigurnosti učesnika projekta ispod 5 % (k = 2). U okviru projekta še biti sprovedena Dodatna interkomparacija kalibracionih faktora za ambijentalni dozni ekvivalent. Ova interkomparacija še pomoši učesnicima projekta da validiraju merne mogušnosti razvijene pre i tokom projekta, a takođe će pomoći novim institutima da steknu međunarodno priznanje. U okviru intercomparacije, biše pokriveni kvaliteti zračenja radionuklida, kao i x-zračenja., Accurate and traceable measurements of operational quantities are required for adequate radiation protection. National Measurement Institutes (NMI) and Designated Institutes (DI) are responsible for disseminating the SI unit sievert and for calibrating user equipment. However, in many emerging European countries, calibration and measurement capabilities for operational quantities are limited or nonexistent. The main objective of DOSEtrace project is to improve these capabilities and for the participants to achieve the expanded measurement uncertainty of less than5% (k = 2). Within the project, a Supplementary comparison of calibration factors in terms of ambient dose equivalent will be conducted. This comparison will help to validate the capabilities that the partners developed during and before the project and will help emerging institutes gain international recognition. The comparison will cover both radionuclide and x-ray radiation qualities according to ISO 4037-1.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "30. симпозијум ДЗЗСЦГ : зборник радова",
title = "EURAMET i DOSEtrace projekat i dodatna interkomparacija, EURAMET i DOSEtrace project and supplementary comparison",
pages = "472-477",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8717"
}
Živanović, M. Z., Hupe, O., Šabeta, A., Kržanović, N.,& Makarić, V.. (2019). EURAMET i DOSEtrace projekat i dodatna interkomparacija. in 30. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 472-477.
https://hdl.handle.net/21.15107/rcub_vinar_8717
Živanović MZ, Hupe O, Šabeta A, Kržanović N, Makarić V. EURAMET i DOSEtrace projekat i dodatna interkomparacija. in 30. симпозијум ДЗЗСЦГ : зборник радова. 2019;:472-477.
https://hdl.handle.net/21.15107/rcub_vinar_8717 .
Živanović, Miloš Z., Hupe, Oliver, Šabeta, Amra, Kržanović, Nikola, Makarić, Vedrana, "EURAMET i DOSEtrace projekat i dodatna interkomparacija" in 30. симпозијум ДЗЗСЦГ : зборник радова (2019):472-477,
https://hdl.handle.net/21.15107/rcub_vinar_8717 .