Tomić, Milan

Link to this page

Authority KeyName Variants
e6b4439b-5f41-45c1-b4a8-51e3f551b879
  • Tomić, Milan (1)
Projects

Author's Bibliography

Comparison of methods for determination of biogenic fraction in liquid fuels

Barešić, Jadranka; Nikolov, Jovana; Todorović, Nataša; Krajcar Bronić, Ines; Stojković, Ivana; Tenjović, Branislava; Krmpotić, Matea; Tomić, Milan; Marić, Dragana

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2017)

TY  - CONF
AU  - Barešić, Jadranka
AU  - Nikolov, Jovana
AU  - Todorović, Nataša
AU  - Krajcar Bronić, Ines
AU  - Stojković, Ivana
AU  - Tenjović, Branislava
AU  - Krmpotić, Matea
AU  - Tomić, Milan
AU  - Marić, Dragana
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8325
UR  - https://plus.sr.cobiss.net/opac7/bib/245691404
UR  - http://dzz.org.rs/wp-content/uploads/2013/06/Zbornik_XXIX_Simpozijum_DZZ_SCG_Srebrno_jezero_2.pdf
AB  - A method of direct measurement of 14C activity concentration via liquid scintillation
counting (LSC) is recognized as good and fast method for determination of biogenic
component in liquid fuels. Two laboratories that used this14C technique participated in
this survey: Laboratory from University of Novi Sad (UNS), Serbia and Laboratory
from Ruđer Bošković Institute (RBI), Croatia. Each laboratory used its own calibration
methods on the same set of samples (produced diesel-based bio-fuels and commercially
available domestic oils).
From the obtained results it can be concluded that each method which uses 14C
technique for determination of biogenic component in liquid fuels has its advantages
and disadvantages. RBI data evaluation method is based on two calibration curves, for
purely biogenic and purely fossil liquids, and the calibration does not depend on the
exact chemical composition of the organic liquid. The limits of the method are defined
by the SQP(E) of approximately 690. Below this value the count rates of biogenic and
fossil liquids become close to each other or even indistinguishable from one another
and the obtained results for biogenic fractions are not reliable. In this intercomparison
UNS used two different methods, one for produced bio-diesels and the other one for
domestic oils. UNS data evaluation method is very dependent on the composition of the
examined fuels, so the obtained results with the "two-step" method were relatively good
in the case of diesel mixtures with biogenic component. In the case of biogenic oil
samples (bought on market), UNS "two-step" method did not give realistic results, and
with the "one-step" method the limitation is large quenching in the samples, so for the
samples with SQP(E) less than 700 this method could not give expected results. Samples
prepared with liquid fuels are usually colored and the main challenge for determination
of biogenic component in both laboratories is handling of highly quenched liquids.
AB  - Prema preporukama Evropske Unije sa ciljem da se koriste obnovljivi i održivi izvori,
do 2020. godine zahteva se da se u svim tečnim gorivima koja se koriste nalazi bar 10%
sintetisanog biodizela. Da bi se koncentracija biodizela mogla proveriti, nekoliko
laboratorija u svetu je razvilo metode za tačnu, efikasnu i pouzdanu kvantifikaciju
sadržaja biogene komponente. Direktno merenje koncentracije aktivnosti 14C tečnim
scintilacionim detektorom (LSC), koje podrazumeva određivanje količine 14C u uzorku
kao meru prisutnosti biogene komponente u testiranom gorivu, pokazalo se kao dobra i
brza metoda. U ovoj interkomparaciji učestvovale su dve laboratorije: Laboratorija sa
Univerziteta u Novom Sadu (UNS), Srbija i Laboratorija sa Instituta Ruđer Bošković
(RBI), Hrvatska. Svaka laboratorija je koristila sopstveni kalibracioni metod i isti set
uzoraka za interkomparaciju (proizvedena bio-goriva bazirana na dizelu i komercijalno
dostupna domaća ulja).
Iz dobijenih rezultata može se zaključiti da svaki od prikazanih metoda ima svoje
prednosti i mane, što zavisi od samog sastava uzorka. RBI metod se zasniva na upotrebi
dve kalibracione krive, za čisto biogena i čisto fosilna goriva, i kalibracija nije zavisna
od hemijskog sastava analiziranog uzorka. Ograničenje ove metode je SQP(E) vrednost
niža od 690. Ispod ove vrednosti odbroji biogene i fosilne komponente postaju veoma
bliski jedan drugom i samim tim rezultati koji se dobijaju nisu pouzdani. U ovoj
interkomparaciji, UNS je koristila dve različite metode kalibracije, jednu za
proizvedene bio-dizele, a drugu za domaća ulja. UNS metod evaluacije izmerenih
podataka u mnogome zavisi od sastava ispitivanog goriva, pa su rezultati dobijeni sa
"two-step" metodom relativno dobri za smeše dizela sa biogenom komponentom. U
slučaju biogenih ulja, UNS "two-step" metod nije dao realistične rezultate, zbog toga je
korišćen "one-step" metoda za koji je utvrđeno ograničenje za SQP(E) parametar na
700.
Uzorci koji se pripremaju sa tečnim gorivima su najčešće obojeni i najveći problem koji
se javlja je korekcija na prigušenje u samom uzorku, koja mora biti detaljno sprovedena
kako bi se dobio pouzdan rezultat, pa najveći izazov daljnjeg razvoja ovih metoda
postaje postupak merenja biogene komponente u jako prigušenim uzorcima.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 29. симпозијум ДЗЗСЦГ : зборник радова
T1  - Comparison of methods for determination of biogenic fraction in liquid fuels
T1  - Poređenje metoda za određivanje biogene komponente u tečnim gorivima
SP  - 529
EP  - 536
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8325
ER  - 
@conference{
author = "Barešić, Jadranka and Nikolov, Jovana and Todorović, Nataša and Krajcar Bronić, Ines and Stojković, Ivana and Tenjović, Branislava and Krmpotić, Matea and Tomić, Milan and Marić, Dragana",
year = "2017",
abstract = "A method of direct measurement of 14C activity concentration via liquid scintillation
counting (LSC) is recognized as good and fast method for determination of biogenic
component in liquid fuels. Two laboratories that used this14C technique participated in
this survey: Laboratory from University of Novi Sad (UNS), Serbia and Laboratory
from Ruđer Bošković Institute (RBI), Croatia. Each laboratory used its own calibration
methods on the same set of samples (produced diesel-based bio-fuels and commercially
available domestic oils).
From the obtained results it can be concluded that each method which uses 14C
technique for determination of biogenic component in liquid fuels has its advantages
and disadvantages. RBI data evaluation method is based on two calibration curves, for
purely biogenic and purely fossil liquids, and the calibration does not depend on the
exact chemical composition of the organic liquid. The limits of the method are defined
by the SQP(E) of approximately 690. Below this value the count rates of biogenic and
fossil liquids become close to each other or even indistinguishable from one another
and the obtained results for biogenic fractions are not reliable. In this intercomparison
UNS used two different methods, one for produced bio-diesels and the other one for
domestic oils. UNS data evaluation method is very dependent on the composition of the
examined fuels, so the obtained results with the "two-step" method were relatively good
in the case of diesel mixtures with biogenic component. In the case of biogenic oil
samples (bought on market), UNS "two-step" method did not give realistic results, and
with the "one-step" method the limitation is large quenching in the samples, so for the
samples with SQP(E) less than 700 this method could not give expected results. Samples
prepared with liquid fuels are usually colored and the main challenge for determination
of biogenic component in both laboratories is handling of highly quenched liquids., Prema preporukama Evropske Unije sa ciljem da se koriste obnovljivi i održivi izvori,
do 2020. godine zahteva se da se u svim tečnim gorivima koja se koriste nalazi bar 10%
sintetisanog biodizela. Da bi se koncentracija biodizela mogla proveriti, nekoliko
laboratorija u svetu je razvilo metode za tačnu, efikasnu i pouzdanu kvantifikaciju
sadržaja biogene komponente. Direktno merenje koncentracije aktivnosti 14C tečnim
scintilacionim detektorom (LSC), koje podrazumeva određivanje količine 14C u uzorku
kao meru prisutnosti biogene komponente u testiranom gorivu, pokazalo se kao dobra i
brza metoda. U ovoj interkomparaciji učestvovale su dve laboratorije: Laboratorija sa
Univerziteta u Novom Sadu (UNS), Srbija i Laboratorija sa Instituta Ruđer Bošković
(RBI), Hrvatska. Svaka laboratorija je koristila sopstveni kalibracioni metod i isti set
uzoraka za interkomparaciju (proizvedena bio-goriva bazirana na dizelu i komercijalno
dostupna domaća ulja).
Iz dobijenih rezultata može se zaključiti da svaki od prikazanih metoda ima svoje
prednosti i mane, što zavisi od samog sastava uzorka. RBI metod se zasniva na upotrebi
dve kalibracione krive, za čisto biogena i čisto fosilna goriva, i kalibracija nije zavisna
od hemijskog sastava analiziranog uzorka. Ograničenje ove metode je SQP(E) vrednost
niža od 690. Ispod ove vrednosti odbroji biogene i fosilne komponente postaju veoma
bliski jedan drugom i samim tim rezultati koji se dobijaju nisu pouzdani. U ovoj
interkomparaciji, UNS je koristila dve različite metode kalibracije, jednu za
proizvedene bio-dizele, a drugu za domaća ulja. UNS metod evaluacije izmerenih
podataka u mnogome zavisi od sastava ispitivanog goriva, pa su rezultati dobijeni sa
"two-step" metodom relativno dobri za smeše dizela sa biogenom komponentom. U
slučaju biogenih ulja, UNS "two-step" metod nije dao realistične rezultate, zbog toga je
korišćen "one-step" metoda za koji je utvrđeno ograničenje za SQP(E) parametar na
700.
Uzorci koji se pripremaju sa tečnim gorivima su najčešće obojeni i najveći problem koji
se javlja je korekcija na prigušenje u samom uzorku, koja mora biti detaljno sprovedena
kako bi se dobio pouzdan rezultat, pa najveći izazov daljnjeg razvoja ovih metoda
postaje postupak merenja biogene komponente u jako prigušenim uzorcima.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "29. симпозијум ДЗЗСЦГ : зборник радова",
title = "Comparison of methods for determination of biogenic fraction in liquid fuels, Poređenje metoda za određivanje biogene komponente u tečnim gorivima",
pages = "529-536",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8325"
}
Barešić, J., Nikolov, J., Todorović, N., Krajcar Bronić, I., Stojković, I., Tenjović, B., Krmpotić, M., Tomić, M.,& Marić, D.. (2017). Comparison of methods for determination of biogenic fraction in liquid fuels. in 29. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 529-536.
https://hdl.handle.net/21.15107/rcub_vinar_8325
Barešić J, Nikolov J, Todorović N, Krajcar Bronić I, Stojković I, Tenjović B, Krmpotić M, Tomić M, Marić D. Comparison of methods for determination of biogenic fraction in liquid fuels. in 29. симпозијум ДЗЗСЦГ : зборник радова. 2017;:529-536.
https://hdl.handle.net/21.15107/rcub_vinar_8325 .
Barešić, Jadranka, Nikolov, Jovana, Todorović, Nataša, Krajcar Bronić, Ines, Stojković, Ivana, Tenjović, Branislava, Krmpotić, Matea, Tomić, Milan, Marić, Dragana, "Comparison of methods for determination of biogenic fraction in liquid fuels" in 29. симпозијум ДЗЗСЦГ : зборник радова (2017):529-536,
https://hdl.handle.net/21.15107/rcub_vinar_8325 .