Ćeklić, Sandra

Link to this page

Authority KeyName Variants
bd32b4d2-4390-4257-90ce-c7ceeba7ccbc
  • Ćeklić, Sandra (12)
  • Ćeklić, Sandra M. (1)
Projects

Author's Bibliography

Monitoring doze za očno sočivo u interventnoj radiologiji i kardiologiji

Ciraj-Bjelac, Olivera; Aranđić, Danijela; Božović, Predrag; Ćeklić, Sandra; Stanković-Petrović, Jelena S.; Kaljević, Jelica

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2017)

TY  - CONF
AU  - Ciraj-Bjelac, Olivera
AU  - Aranđić, Danijela
AU  - Božović, Predrag
AU  - Ćeklić, Sandra
AU  - Stanković-Petrović, Jelena S.
AU  - Kaljević, Jelica
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8280
UR  - https://plus.sr.cobiss.net/opac7/bib/245691404
UR  - http://dzz.org.rs/wp-content/uploads/2013/06/Zbornik_XXIX_Simpozijum_DZZ_SCG_Srebrno_jezero_2.pdf
AB  - Sledeći rezultate epidemioloških studija o efektu jonizujućih zračenja na očno stočivo,
Međunarodna komisija za zaštitu od zračenja revidirala je granicu izlaganja za očno
sočivo, imajući u vidu da u slučaju dugotrajnog izlaganja malim dozama i malim
jačinama doza na radnom mestu, katarakta može nastati na nivou doze daleko manjim
od ranije utvrđenog praga. Ovakve situacije su tipične za profesionalna izlaganja u
interventnoj kardiologiji i radiologiji. Cilj ovog rada je prikaz metodologije za
donošenje odluke o potrebi za individualnim monitringom za očno sočivo i prikaz
rezultata pilot monitoringa u interventnoj kardiologiji pomoću namenskih dozimetara
za očno sočivo kalibrisanim u dozimetrijskoj veličini lični dozni ekvivalent Hp(3).
AB  - Following recent epidemiological evidences on effects of ionizing radiation to the eye
lens, International Commission on Radiological Protection has re-evaluated dose limit
to the lens of the eye, owing that protracted exposure to the relatively small doses and
dose rates may lead to the cataract at dose levels much lower than previously set dose
thresholds. Such satiations are typical for occupational exposure in interventional
cardiology and radiology. Occupational exposure from interventional x-ray procedures
is an area in which increased eye lens exposure may occur. Accurate dosimetry is an
important element to investigate the correlation of observed radiation effects with
radiation dose, to verify the compliance with regulatory dose limits, and to optimize
radiation protection practice. The papers presents the overview of practical methods for
eye lens doses assessment as well as typical occupational eye lens dose levels in
interventional procedures in cardiology and radiology. In addition, a methodology to
assist decision making about need for specific eye lens individual monitoring using a
dedicated passive dosimeters calibrated in terms of Hp(3) is presented in this paper.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 29. симпозијум ДЗЗСЦГ : зборник радова
T1  - Monitoring doze za očno sočivo u interventnoj radiologiji i kardiologiji
T1  - Eye lens monitoring in interventional cardiology and radiology
SP  - 241
EP  - 248
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8280
ER  - 
@conference{
author = "Ciraj-Bjelac, Olivera and Aranđić, Danijela and Božović, Predrag and Ćeklić, Sandra and Stanković-Petrović, Jelena S. and Kaljević, Jelica",
year = "2017",
abstract = "Sledeći rezultate epidemioloških studija o efektu jonizujućih zračenja na očno stočivo,
Međunarodna komisija za zaštitu od zračenja revidirala je granicu izlaganja za očno
sočivo, imajući u vidu da u slučaju dugotrajnog izlaganja malim dozama i malim
jačinama doza na radnom mestu, katarakta može nastati na nivou doze daleko manjim
od ranije utvrđenog praga. Ovakve situacije su tipične za profesionalna izlaganja u
interventnoj kardiologiji i radiologiji. Cilj ovog rada je prikaz metodologije za
donošenje odluke o potrebi za individualnim monitringom za očno sočivo i prikaz
rezultata pilot monitoringa u interventnoj kardiologiji pomoću namenskih dozimetara
za očno sočivo kalibrisanim u dozimetrijskoj veličini lični dozni ekvivalent Hp(3)., Following recent epidemiological evidences on effects of ionizing radiation to the eye
lens, International Commission on Radiological Protection has re-evaluated dose limit
to the lens of the eye, owing that protracted exposure to the relatively small doses and
dose rates may lead to the cataract at dose levels much lower than previously set dose
thresholds. Such satiations are typical for occupational exposure in interventional
cardiology and radiology. Occupational exposure from interventional x-ray procedures
is an area in which increased eye lens exposure may occur. Accurate dosimetry is an
important element to investigate the correlation of observed radiation effects with
radiation dose, to verify the compliance with regulatory dose limits, and to optimize
radiation protection practice. The papers presents the overview of practical methods for
eye lens doses assessment as well as typical occupational eye lens dose levels in
interventional procedures in cardiology and radiology. In addition, a methodology to
assist decision making about need for specific eye lens individual monitoring using a
dedicated passive dosimeters calibrated in terms of Hp(3) is presented in this paper.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "29. симпозијум ДЗЗСЦГ : зборник радова",
title = "Monitoring doze za očno sočivo u interventnoj radiologiji i kardiologiji, Eye lens monitoring in interventional cardiology and radiology",
pages = "241-248",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8280"
}
Ciraj-Bjelac, O., Aranđić, D., Božović, P., Ćeklić, S., Stanković-Petrović, J. S.,& Kaljević, J.. (2017). Monitoring doze za očno sočivo u interventnoj radiologiji i kardiologiji. in 29. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 241-248.
https://hdl.handle.net/21.15107/rcub_vinar_8280
Ciraj-Bjelac O, Aranđić D, Božović P, Ćeklić S, Stanković-Petrović JS, Kaljević J. Monitoring doze za očno sočivo u interventnoj radiologiji i kardiologiji. in 29. симпозијум ДЗЗСЦГ : зборник радова. 2017;:241-248.
https://hdl.handle.net/21.15107/rcub_vinar_8280 .
Ciraj-Bjelac, Olivera, Aranđić, Danijela, Božović, Predrag, Ćeklić, Sandra, Stanković-Petrović, Jelena S., Kaljević, Jelica, "Monitoring doze za očno sočivo u interventnoj radiologiji i kardiologiji" in 29. симпозијум ДЗЗСЦГ : зборник радова (2017):241-248,
https://hdl.handle.net/21.15107/rcub_vinar_8280 .

Konstrukcija sekundarnog etalona za veličinu lični dozni ekvivalent Hp(3) pomoću Monte Karlo simulacija

Ćeklić, Sandra; Ciraj-Bjelac, Olivera; Aranđić, Danijela; Stanković-Petrović, Jelena S.; Božović, Predrag; Mihailescu Liviu, Cristian

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2017)

TY  - CONF
AU  - Ćeklić, Sandra
AU  - Ciraj-Bjelac, Olivera
AU  - Aranđić, Danijela
AU  - Stanković-Petrović, Jelena S.
AU  - Božović, Predrag
AU  - Mihailescu Liviu, Cristian
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8288
UR  - https://plus.sr.cobiss.net/opac7/bib/245691404
UR  - http://dzz.org.rs/wp-content/uploads/2013/06/Zbornik_XXIX_Simpozijum_DZZ_SCG_Srebrno_jezero_2.pdf
AB  - U ovom radu prikazani su rezultati ispitivanja mogućeg dizajna sekundarnog etalona za
lični dozni ekvivalent Hp(3) pomoću Monte Karlo simulacija. Simulirana je sferna
jonizaciona komora ugrađena u sferni fantom. Ispitivana je energetska i ugaona
zavisnost i cilj je bio da se postigne što konstantniji odgovor u širokom opsegu energija.
Rezultati pokazuju da se najadekvatniji dizajn postize jonizacionom komorom TK-30
ugrađenom u sferni fantom od polimetil-metakrilata (PMMA) prečnika 15 cm.
Energetski odgovor je u ±10% za opseg energija od (18 do 1250) keV, dok je ugaoni
odgovor u ±20% za upadni ugao u opsegu od 0 do 90º za energetski opseg od (48 do
1250) keV.
AB  - In this paper possible design for secondary standard Hp(3) ionisation chamber was
investigated using Monte Carlo simulations. The simulations were performed for
spherical ionization chamber surrounded by spherical phantom. The goal was to obtain
the more constant energy and angular response in wide energy range in order to get
optimal geometry. The results shown that the most adequate design for secondary
standard Hp(3) was achieved using commercially available TK-30 ionization chamber
manufactured by PTW embedded in spherical polymethyl methacrylate (PMMA)
phantom with diameter 15 cm. The energy response was within ±10% in range of
photon energies from (18 to 1250) keV, while angular response was within ±20% for
angle of incidence α from 0º to 90º for energy range (48 to 1250) keV.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 29. симпозијум ДЗЗСЦГ : зборник радова
T1  - Konstrukcija sekundarnog etalona za veličinu lični dozni ekvivalent Hp(3) pomoću Monte Karlo simulacija
T1  - Design of secondary standard Hp(3) ionisation chamber using Monte Carlo simulations
SP  - 287
EP  - 290
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8288
ER  - 
@conference{
author = "Ćeklić, Sandra and Ciraj-Bjelac, Olivera and Aranđić, Danijela and Stanković-Petrović, Jelena S. and Božović, Predrag and Mihailescu Liviu, Cristian",
year = "2017",
abstract = "U ovom radu prikazani su rezultati ispitivanja mogućeg dizajna sekundarnog etalona za
lični dozni ekvivalent Hp(3) pomoću Monte Karlo simulacija. Simulirana je sferna
jonizaciona komora ugrađena u sferni fantom. Ispitivana je energetska i ugaona
zavisnost i cilj je bio da se postigne što konstantniji odgovor u širokom opsegu energija.
Rezultati pokazuju da se najadekvatniji dizajn postize jonizacionom komorom TK-30
ugrađenom u sferni fantom od polimetil-metakrilata (PMMA) prečnika 15 cm.
Energetski odgovor je u ±10% za opseg energija od (18 do 1250) keV, dok je ugaoni
odgovor u ±20% za upadni ugao u opsegu od 0 do 90º za energetski opseg od (48 do
1250) keV., In this paper possible design for secondary standard Hp(3) ionisation chamber was
investigated using Monte Carlo simulations. The simulations were performed for
spherical ionization chamber surrounded by spherical phantom. The goal was to obtain
the more constant energy and angular response in wide energy range in order to get
optimal geometry. The results shown that the most adequate design for secondary
standard Hp(3) was achieved using commercially available TK-30 ionization chamber
manufactured by PTW embedded in spherical polymethyl methacrylate (PMMA)
phantom with diameter 15 cm. The energy response was within ±10% in range of
photon energies from (18 to 1250) keV, while angular response was within ±20% for
angle of incidence α from 0º to 90º for energy range (48 to 1250) keV.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "29. симпозијум ДЗЗСЦГ : зборник радова",
title = "Konstrukcija sekundarnog etalona za veličinu lični dozni ekvivalent Hp(3) pomoću Monte Karlo simulacija, Design of secondary standard Hp(3) ionisation chamber using Monte Carlo simulations",
pages = "287-290",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8288"
}
Ćeklić, S., Ciraj-Bjelac, O., Aranđić, D., Stanković-Petrović, J. S., Božović, P.,& Mihailescu Liviu, C.. (2017). Konstrukcija sekundarnog etalona za veličinu lični dozni ekvivalent Hp(3) pomoću Monte Karlo simulacija. in 29. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 287-290.
https://hdl.handle.net/21.15107/rcub_vinar_8288
Ćeklić S, Ciraj-Bjelac O, Aranđić D, Stanković-Petrović JS, Božović P, Mihailescu Liviu C. Konstrukcija sekundarnog etalona za veličinu lični dozni ekvivalent Hp(3) pomoću Monte Karlo simulacija. in 29. симпозијум ДЗЗСЦГ : зборник радова. 2017;:287-290.
https://hdl.handle.net/21.15107/rcub_vinar_8288 .
Ćeklić, Sandra, Ciraj-Bjelac, Olivera, Aranđić, Danijela, Stanković-Petrović, Jelena S., Božović, Predrag, Mihailescu Liviu, Cristian, "Konstrukcija sekundarnog etalona za veličinu lični dozni ekvivalent Hp(3) pomoću Monte Karlo simulacija" in 29. симпозијум ДЗЗСЦГ : зборник радова (2017):287-290,
https://hdl.handle.net/21.15107/rcub_vinar_8288 .

Performance Testing of Selected Types of Electronic Personal Dosimeters in X-And Gamma Radiation Fields

Kržanović, Nikola; Živanović, Miloš Z.; Ciraj-Bjelac, Olivera; Lazarević, Đorđe R.; Ćeklić, Sandra; Stanković, Srboljub J.

(2017)

TY  - JOUR
AU  - Kržanović, Nikola
AU  - Živanović, Miloš Z.
AU  - Ciraj-Bjelac, Olivera
AU  - Lazarević, Đorđe R.
AU  - Ćeklić, Sandra
AU  - Stanković, Srboljub J.
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/1704
AB  - Electronic personal dosimeters (EPDs) are increasingly being used alongside conventional thermoluminescent dosimeters to measure the dose of legal record in terms of personal dose equivalent. Therefore, it is of great importance to execute performance tests of these dosimeters in photon fields of various energies and at various angles of incidence. This testing is done in order to simulate the behavior of these dosimeters in realistic multidirectional polyenergetic ionizing radiation fields. Tests of accuracy, linearity, energy response, and angular response have been performed on 10 EPDs from multiple manufacturers. Various radiation qualities have been used in the energy range from 33 keV to 1.33 MeV and for angles of incidence 0 degrees to 80 degrees. This research proves that many of the EPDs tested performed according to the manufacturers specifications and the requirements of the international standards regarding personal dosimetry.
T2  - Health Physics
T1  - Performance Testing of Selected Types of Electronic Personal Dosimeters in X-And Gamma Radiation Fields
VL  - 113
IS  - 4
SP  - 252
EP  - 261
DO  - 10.1097/HP.0000000000000704
ER  - 
@article{
author = "Kržanović, Nikola and Živanović, Miloš Z. and Ciraj-Bjelac, Olivera and Lazarević, Đorđe R. and Ćeklić, Sandra and Stanković, Srboljub J.",
year = "2017",
abstract = "Electronic personal dosimeters (EPDs) are increasingly being used alongside conventional thermoluminescent dosimeters to measure the dose of legal record in terms of personal dose equivalent. Therefore, it is of great importance to execute performance tests of these dosimeters in photon fields of various energies and at various angles of incidence. This testing is done in order to simulate the behavior of these dosimeters in realistic multidirectional polyenergetic ionizing radiation fields. Tests of accuracy, linearity, energy response, and angular response have been performed on 10 EPDs from multiple manufacturers. Various radiation qualities have been used in the energy range from 33 keV to 1.33 MeV and for angles of incidence 0 degrees to 80 degrees. This research proves that many of the EPDs tested performed according to the manufacturers specifications and the requirements of the international standards regarding personal dosimetry.",
journal = "Health Physics",
title = "Performance Testing of Selected Types of Electronic Personal Dosimeters in X-And Gamma Radiation Fields",
volume = "113",
number = "4",
pages = "252-261",
doi = "10.1097/HP.0000000000000704"
}
Kržanović, N., Živanović, M. Z., Ciraj-Bjelac, O., Lazarević, Đ. R., Ćeklić, S.,& Stanković, S. J.. (2017). Performance Testing of Selected Types of Electronic Personal Dosimeters in X-And Gamma Radiation Fields. in Health Physics, 113(4), 252-261.
https://doi.org/10.1097/HP.0000000000000704
Kržanović N, Živanović MZ, Ciraj-Bjelac O, Lazarević ĐR, Ćeklić S, Stanković SJ. Performance Testing of Selected Types of Electronic Personal Dosimeters in X-And Gamma Radiation Fields. in Health Physics. 2017;113(4):252-261.
doi:10.1097/HP.0000000000000704 .
Kržanović, Nikola, Živanović, Miloš Z., Ciraj-Bjelac, Olivera, Lazarević, Đorđe R., Ćeklić, Sandra, Stanković, Srboljub J., "Performance Testing of Selected Types of Electronic Personal Dosimeters in X-And Gamma Radiation Fields" in Health Physics, 113, no. 4 (2017):252-261,
https://doi.org/10.1097/HP.0000000000000704 . .
14
8
13

Monte Karlo simulacija radijacionih oštećenja u zaštitnim materijalima Am-Be-241 neutronskog izvora

Božović, Predrag; Ciraj-Bjelac, Olivera; Aranđić, Danijela; Ćeklić, Sandra; Lazarević, Đorđe R.

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2017)

TY  - CONF
AU  - Božović, Predrag
AU  - Ciraj-Bjelac, Olivera
AU  - Aranđić, Danijela
AU  - Ćeklić, Sandra
AU  - Lazarević, Đorđe R.
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8287
UR  - https://plus.sr.cobiss.net/opac7/bib/245691404
UR  - http://dzz.org.rs/wp-content/uploads/2013/06/Zbornik_XXIX_Simpozijum_DZZ_SCG_Srebrno_jezero_2.pdf
AB  - Radijaciona oštećenja nastaju usled izmeštanja atoma materijala pri elastičnom
rasejavanju čestica upadnog zračenja na jezgrima ili zbog nuklearnih reakcija
izazvanih upadnim zračenjem. Broj izmeštanja po atomu (DPA) je veličina kojom se
opisuje radijaciono oštećenje. S obzirom da je neutronsko zračenje naročito efikasno u
izmeštanju atoma, ispitan je uticaj neutrona na sastavne elemente strukturalne zaštite
241Am-Be neutronskog izvora sastavljene od parafina, betona i olova. Proračun DPA je
obavljen na osnovu rezultata simulacija primenom MCNPX prorgamskog paketa.
AB  - Radiation damage in materials results from nuclear collisions and reactions which
produce energetic recoil atoms of the host materials or reaction products. Displacement
per atom (DPA) is used to quantify radiation damage. Since neutrons are particularly
efficient in displacing atoms, their influence on constituent elements of 241Am-Be
neutron source shielding made of paraffin, concrete and lead. DPA was calculated
based on simulations using MCNPX.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 29. симпозијум ДЗЗСЦГ : зборник радова
T1  - Monte Karlo simulacija radijacionih oštećenja u zaštitnim materijalima Am-Be-241 neutronskog izvora
T1  - Monte Carlo simulation of radiation damage in shielding materials of Am-Be-241 neutron source
SP  - 283
EP  - 286
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8287
ER  - 
@conference{
author = "Božović, Predrag and Ciraj-Bjelac, Olivera and Aranđić, Danijela and Ćeklić, Sandra and Lazarević, Đorđe R.",
year = "2017",
abstract = "Radijaciona oštećenja nastaju usled izmeštanja atoma materijala pri elastičnom
rasejavanju čestica upadnog zračenja na jezgrima ili zbog nuklearnih reakcija
izazvanih upadnim zračenjem. Broj izmeštanja po atomu (DPA) je veličina kojom se
opisuje radijaciono oštećenje. S obzirom da je neutronsko zračenje naročito efikasno u
izmeštanju atoma, ispitan je uticaj neutrona na sastavne elemente strukturalne zaštite
241Am-Be neutronskog izvora sastavljene od parafina, betona i olova. Proračun DPA je
obavljen na osnovu rezultata simulacija primenom MCNPX prorgamskog paketa., Radiation damage in materials results from nuclear collisions and reactions which
produce energetic recoil atoms of the host materials or reaction products. Displacement
per atom (DPA) is used to quantify radiation damage. Since neutrons are particularly
efficient in displacing atoms, their influence on constituent elements of 241Am-Be
neutron source shielding made of paraffin, concrete and lead. DPA was calculated
based on simulations using MCNPX.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "29. симпозијум ДЗЗСЦГ : зборник радова",
title = "Monte Karlo simulacija radijacionih oštećenja u zaštitnim materijalima Am-Be-241 neutronskog izvora, Monte Carlo simulation of radiation damage in shielding materials of Am-Be-241 neutron source",
pages = "283-286",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8287"
}
Božović, P., Ciraj-Bjelac, O., Aranđić, D., Ćeklić, S.,& Lazarević, Đ. R.. (2017). Monte Karlo simulacija radijacionih oštećenja u zaštitnim materijalima Am-Be-241 neutronskog izvora. in 29. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 283-286.
https://hdl.handle.net/21.15107/rcub_vinar_8287
Božović P, Ciraj-Bjelac O, Aranđić D, Ćeklić S, Lazarević ĐR. Monte Karlo simulacija radijacionih oštećenja u zaštitnim materijalima Am-Be-241 neutronskog izvora. in 29. симпозијум ДЗЗСЦГ : зборник радова. 2017;:283-286.
https://hdl.handle.net/21.15107/rcub_vinar_8287 .
Božović, Predrag, Ciraj-Bjelac, Olivera, Aranđić, Danijela, Ćeklić, Sandra, Lazarević, Đorđe R., "Monte Karlo simulacija radijacionih oštećenja u zaštitnim materijalima Am-Be-241 neutronskog izvora" in 29. симпозијум ДЗЗСЦГ : зборник радова (2017):283-286,
https://hdl.handle.net/21.15107/rcub_vinar_8287 .

Interkomparacijska mjerenja u oblasti ispitivanja rendgen-aparata

Berišaj, Benard; Ćeklić, Sandra; Milatović, Aleksandra; Ciraj-Bjelac, Olivera

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2017)

TY  - CONF
AU  - Berišaj, Benard
AU  - Ćeklić, Sandra
AU  - Milatović, Aleksandra
AU  - Ciraj-Bjelac, Olivera
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8293
UR  - https://plus.sr.cobiss.net/opac7/bib/245691404
UR  - http://dzz.org.rs/wp-content/uploads/2013/06/Zbornik_XXIX_Simpozijum_DZZ_SCG_Srebrno_jezero_2.pdf
AB  - U radu su prikazani rezultati interkomparacije dvije laboratorije iz oblasti ispitivanja
rendgen-aparata u Crnoj Gori i Srbiji. Međulaboratorijsko poređenje se odnosi na
mjernu opremu Barracuda RTI Elektonics sa MPD detektorom koja služi za ispitivanje
rendgen uređaja na osnovu standardnih protokola za QC u dijagnostičkoj radiologiji.
Osnovni zadatak interkomparacije bio je verifikacija tehničkih karakteristika mjernog
aparata sa kojim se kontroliše niz parametara koji utiču na kvalitet rada rendgen- aparata. Interkomparacija se odnosi na mjerne veličine: napon rendgenske cijevi, jačina
kerme u vazduhu i debljinu poluslabljenja (HVL). U radu je opisana metodologija i
naćin organizacije interkomparacije a prikazani su i postignuti rezultati i zaključak.
AB  - Results of inter-comparison of two laboratories, dealing with examination of X-ray
units in Montenegro and Serbia, have been presented in this work. Inter- laboratory
comparison is related to measuring equipment Barracuda RTI Electronics with MPD
detector, which is used for examination of X-ray units on the basis of standard protocols
for QC in diagnostic radiology. Basic aim of inter-comparison was to verify technical
characteristics of measuring apparatus, and they are used for control of numerous
parameters which influence the quality of X-ray apparatus performance.
Inter-comparison concerns the following measuring figures: voltage of X-ray tube,
intensity of karma in air and the width of half-attenuation (HVL). Methodology and
organization manner of inter-comparison have been described in this work, and
reached results and conclusion have been presented as well. Measuring results of all
parameters are comparable, even in the interval where measuring uncertainty exists.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 29. симпозијум ДЗЗСЦГ : зборник радова
T1  - Interkomparacijska mjerenja u oblasti ispitivanja rendgen-aparata
T1  - Intercomparisons on measurements in the field of testing X-ray unit
SP  - 315
EP  - 319
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8293
ER  - 
@conference{
author = "Berišaj, Benard and Ćeklić, Sandra and Milatović, Aleksandra and Ciraj-Bjelac, Olivera",
year = "2017",
abstract = "U radu su prikazani rezultati interkomparacije dvije laboratorije iz oblasti ispitivanja
rendgen-aparata u Crnoj Gori i Srbiji. Međulaboratorijsko poređenje se odnosi na
mjernu opremu Barracuda RTI Elektonics sa MPD detektorom koja služi za ispitivanje
rendgen uređaja na osnovu standardnih protokola za QC u dijagnostičkoj radiologiji.
Osnovni zadatak interkomparacije bio je verifikacija tehničkih karakteristika mjernog
aparata sa kojim se kontroliše niz parametara koji utiču na kvalitet rada rendgen- aparata. Interkomparacija se odnosi na mjerne veličine: napon rendgenske cijevi, jačina
kerme u vazduhu i debljinu poluslabljenja (HVL). U radu je opisana metodologija i
naćin organizacije interkomparacije a prikazani su i postignuti rezultati i zaključak., Results of inter-comparison of two laboratories, dealing with examination of X-ray
units in Montenegro and Serbia, have been presented in this work. Inter- laboratory
comparison is related to measuring equipment Barracuda RTI Electronics with MPD
detector, which is used for examination of X-ray units on the basis of standard protocols
for QC in diagnostic radiology. Basic aim of inter-comparison was to verify technical
characteristics of measuring apparatus, and they are used for control of numerous
parameters which influence the quality of X-ray apparatus performance.
Inter-comparison concerns the following measuring figures: voltage of X-ray tube,
intensity of karma in air and the width of half-attenuation (HVL). Methodology and
organization manner of inter-comparison have been described in this work, and
reached results and conclusion have been presented as well. Measuring results of all
parameters are comparable, even in the interval where measuring uncertainty exists.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "29. симпозијум ДЗЗСЦГ : зборник радова",
title = "Interkomparacijska mjerenja u oblasti ispitivanja rendgen-aparata, Intercomparisons on measurements in the field of testing X-ray unit",
pages = "315-319",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8293"
}
Berišaj, B., Ćeklić, S., Milatović, A.,& Ciraj-Bjelac, O.. (2017). Interkomparacijska mjerenja u oblasti ispitivanja rendgen-aparata. in 29. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 315-319.
https://hdl.handle.net/21.15107/rcub_vinar_8293
Berišaj B, Ćeklić S, Milatović A, Ciraj-Bjelac O. Interkomparacijska mjerenja u oblasti ispitivanja rendgen-aparata. in 29. симпозијум ДЗЗСЦГ : зборник радова. 2017;:315-319.
https://hdl.handle.net/21.15107/rcub_vinar_8293 .
Berišaj, Benard, Ćeklić, Sandra, Milatović, Aleksandra, Ciraj-Bjelac, Olivera, "Interkomparacijska mjerenja u oblasti ispitivanja rendgen-aparata" in 29. симпозијум ДЗЗСЦГ : зборник радова (2017):315-319,
https://hdl.handle.net/21.15107/rcub_vinar_8293 .

Calibration, intercomparison and quality control of radionuclide calibrators used in nuclear medicine

Ciraj-Bjelac, Olivera; Saldarriaga Vargas; Janković, Drina; Vukanac, Ivana; Kandić, Aleksandar; Đurašević, Mirjana; Živanović, Miloš; Ćeklić, Sandra; Aranđić, Danijela; Struelens, L.

(2016)

TY  - CONF
AU  - Ciraj-Bjelac, Olivera
AU  - Saldarriaga Vargas
AU  - Janković, Drina
AU  - Vukanac, Ivana
AU  - Kandić, Aleksandar
AU  - Đurašević, Mirjana
AU  - Živanović, Miloš
AU  - Ćeklić, Sandra
AU  - Aranđić, Danijela
AU  - Struelens, L.
PY  - 2016
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12835
C3  - Serbian Congress of Nuclear Medicine 2016 "Nuclear medicine: from function to molecular imaging and therapy" : Book of abstracts
T1  - Calibration, intercomparison and quality control of radionuclide calibrators used in nuclear medicine
SP  - 41
EP  - 41
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12835
ER  - 
@conference{
author = "Ciraj-Bjelac, Olivera and Saldarriaga Vargas and Janković, Drina and Vukanac, Ivana and Kandić, Aleksandar and Đurašević, Mirjana and Živanović, Miloš and Ćeklić, Sandra and Aranđić, Danijela and Struelens, L.",
year = "2016",
journal = "Serbian Congress of Nuclear Medicine 2016 "Nuclear medicine: from function to molecular imaging and therapy" : Book of abstracts",
title = "Calibration, intercomparison and quality control of radionuclide calibrators used in nuclear medicine",
pages = "41-41",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12835"
}
Ciraj-Bjelac, O., Saldarriaga Vargas, Janković, D., Vukanac, I., Kandić, A., Đurašević, M., Živanović, M., Ćeklić, S., Aranđić, D.,& Struelens, L.. (2016). Calibration, intercomparison and quality control of radionuclide calibrators used in nuclear medicine. in Serbian Congress of Nuclear Medicine 2016 "Nuclear medicine: from function to molecular imaging and therapy" : Book of abstracts, 41-41.
https://hdl.handle.net/21.15107/rcub_vinar_12835
Ciraj-Bjelac O, Saldarriaga Vargas, Janković D, Vukanac I, Kandić A, Đurašević M, Živanović M, Ćeklić S, Aranđić D, Struelens L. Calibration, intercomparison and quality control of radionuclide calibrators used in nuclear medicine. in Serbian Congress of Nuclear Medicine 2016 "Nuclear medicine: from function to molecular imaging and therapy" : Book of abstracts. 2016;:41-41.
https://hdl.handle.net/21.15107/rcub_vinar_12835 .
Ciraj-Bjelac, Olivera, Saldarriaga Vargas, Janković, Drina, Vukanac, Ivana, Kandić, Aleksandar, Đurašević, Mirjana, Živanović, Miloš, Ćeklić, Sandra, Aranđić, Danijela, Struelens, L., "Calibration, intercomparison and quality control of radionuclide calibrators used in nuclear medicine" in Serbian Congress of Nuclear Medicine 2016 "Nuclear medicine: from function to molecular imaging and therapy" : Book of abstracts (2016):41-41,
https://hdl.handle.net/21.15107/rcub_vinar_12835 .

Mammography in Serbia: Image Quality and Radiation Dose

Rafajlović, Stefan; Aranđić, Danijela; Božović, Predrag; Ćeklić, Sandra; Lazarević, Đorđe R.; Ciraj-Bjelac, Olivera

(2016)

TY  - CONF
AU  - Rafajlović, Stefan
AU  - Aranđić, Danijela
AU  - Božović, Predrag
AU  - Ćeklić, Sandra
AU  - Lazarević, Đorđe R.
AU  - Ciraj-Bjelac, Olivera
PY  - 2016
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7167
AB  - The purpose of this study is to investigate the radiation dose and technical image quality in mammography in Serbia after two years of implementation of the breast screening programme. A total of 186 mammography units, including Full-Field Digital Mammography (FFDM), Computed Radiography (CR) and Screen-Film Mammography (SFM) units were used in the patient dose and image quality assessment. Patient dose, in terms of Mean Glandular Dose (MGD), was assessed for the standard breast, while image quality was evaluated in terms of spatial resolution, threshold contrast visibility and Contrast to Noise Ratio (CNR) for CR and FFDM units. The mean MGD assessed was (1.8 +/- 0.94) mGy, (1.3 +/- 0.51) and (1.7 +/- 0.64) for CR, FFDM and SFM, respectively. Spatial resolution was better than 12 lp/mm only for 3/186 (1.6%) units. In 34/186 (1896) units, spatial resolution was less than 5 lp/mm. Threshold contrast visibility was better than 1.2 in 41/186 (22%). Mean CNR for CR and FFDM units was 5.2 2.2. Following the initial implementation at the beginning of the population-based breast cancer screening campaign, it is essential to establish an effective system of regular and periodic Quality Control (QC) tests and to ensure that high-quality mammograms with minimal possible radiation dose to population are included in the screening.
C3  - RAD Conference Proceedings
T1  - Mammography in Serbia: Image Quality and Radiation Dose
SP  - 29
EP  - 32
DO  - 10.21175/RadProc.2016.08
ER  - 
@conference{
author = "Rafajlović, Stefan and Aranđić, Danijela and Božović, Predrag and Ćeklić, Sandra and Lazarević, Đorđe R. and Ciraj-Bjelac, Olivera",
year = "2016",
abstract = "The purpose of this study is to investigate the radiation dose and technical image quality in mammography in Serbia after two years of implementation of the breast screening programme. A total of 186 mammography units, including Full-Field Digital Mammography (FFDM), Computed Radiography (CR) and Screen-Film Mammography (SFM) units were used in the patient dose and image quality assessment. Patient dose, in terms of Mean Glandular Dose (MGD), was assessed for the standard breast, while image quality was evaluated in terms of spatial resolution, threshold contrast visibility and Contrast to Noise Ratio (CNR) for CR and FFDM units. The mean MGD assessed was (1.8 +/- 0.94) mGy, (1.3 +/- 0.51) and (1.7 +/- 0.64) for CR, FFDM and SFM, respectively. Spatial resolution was better than 12 lp/mm only for 3/186 (1.6%) units. In 34/186 (1896) units, spatial resolution was less than 5 lp/mm. Threshold contrast visibility was better than 1.2 in 41/186 (22%). Mean CNR for CR and FFDM units was 5.2 2.2. Following the initial implementation at the beginning of the population-based breast cancer screening campaign, it is essential to establish an effective system of regular and periodic Quality Control (QC) tests and to ensure that high-quality mammograms with minimal possible radiation dose to population are included in the screening.",
journal = "RAD Conference Proceedings",
title = "Mammography in Serbia: Image Quality and Radiation Dose",
pages = "29-32",
doi = "10.21175/RadProc.2016.08"
}
Rafajlović, S., Aranđić, D., Božović, P., Ćeklić, S., Lazarević, Đ. R.,& Ciraj-Bjelac, O.. (2016). Mammography in Serbia: Image Quality and Radiation Dose. in RAD Conference Proceedings, 29-32.
https://doi.org/10.21175/RadProc.2016.08
Rafajlović S, Aranđić D, Božović P, Ćeklić S, Lazarević ĐR, Ciraj-Bjelac O. Mammography in Serbia: Image Quality and Radiation Dose. in RAD Conference Proceedings. 2016;:29-32.
doi:10.21175/RadProc.2016.08 .
Rafajlović, Stefan, Aranđić, Danijela, Božović, Predrag, Ćeklić, Sandra, Lazarević, Đorđe R., Ciraj-Bjelac, Olivera, "Mammography in Serbia: Image Quality and Radiation Dose" in RAD Conference Proceedings (2016):29-32,
https://doi.org/10.21175/RadProc.2016.08 . .

Interkomparacije kao važan element osiguranja kvaliteta u metrologiji jonizujućeg zračenja

Živanović, Miloš; Lazarević, Đorđe; Ciraj-Bjelac, Olivera; Stanković, Srboljub; Ćeklić, Sandra M.; Karadžić, Katarina

(Beograd : Univerzitet u Beogradu, Institut za nuklearne nauke "Vinča", 2015)

TY  - CONF
AU  - Živanović, Miloš
AU  - Lazarević, Đorđe
AU  - Ciraj-Bjelac, Olivera
AU  - Stanković, Srboljub
AU  - Ćeklić, Sandra M.
AU  - Karadžić, Katarina
PY  - 2015
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12346
AB  - Interkomparacije predstavljaju vaţnu aktivnost koja dokazuje da su usluge koje pruţaju laboratorije za etaloniranje u skladu sa meĊunarodno prihvaćenim standardima. U oblasti metrologije jonizujućeg zraĉenja, najĉešća su dva tipa interkomparacija – interkomparacije sa termoluminiscentnim dozimetrima i interkomparacije sa jonizacionim komorama ili drugim transfer instrumentima. U ovom radu su predstavljeni rezultati oba tipa interkomparacija u periodu od 2008. do 2014. godine. TakoĊe su analizirani rezultati interkomparacija i objašnjeno je na koji naĉin su otklonjeni uoĉeni problemi.
AB  - Intercomparisons are important activities performed to ensure that the services provided by calibration laboratories to end-users follow internationally accepted standards. Ionizing radiation dosimetry intercomparisons are usually of two types – postal thermoluminescent dosimeter intercomparisons and ionization chamber calibration intercomparisons. In this paper, both types of intercomparisons are discussed together with the results of 7 years of participation in such intercomparisons. Finally, several discrepancies were discovered as a result of intercomparisons analysis and the resolution of the discrepancies was discussed.
PB  - Beograd : Univerzitet u Beogradu, Institut za nuklearne nauke "Vinča"
PB  - Beograd : Društvo za zaštitu od zračenja Srbije i Crne Gore
C3  - 28. симпозијум ДЗЗСЦГ : зборник радова
T1  - Interkomparacije kao važan element osiguranja kvaliteta u metrologiji jonizujućeg zračenja
T1  - Intercomparisons as an important element of quality assurance in metrology of ionising radiation
SP  - 572
EP  - 576
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12346
ER  - 
@conference{
author = "Živanović, Miloš and Lazarević, Đorđe and Ciraj-Bjelac, Olivera and Stanković, Srboljub and Ćeklić, Sandra M. and Karadžić, Katarina",
year = "2015",
abstract = "Interkomparacije predstavljaju vaţnu aktivnost koja dokazuje da su usluge koje pruţaju laboratorije za etaloniranje u skladu sa meĊunarodno prihvaćenim standardima. U oblasti metrologije jonizujućeg zraĉenja, najĉešća su dva tipa interkomparacija – interkomparacije sa termoluminiscentnim dozimetrima i interkomparacije sa jonizacionim komorama ili drugim transfer instrumentima. U ovom radu su predstavljeni rezultati oba tipa interkomparacija u periodu od 2008. do 2014. godine. TakoĊe su analizirani rezultati interkomparacija i objašnjeno je na koji naĉin su otklonjeni uoĉeni problemi., Intercomparisons are important activities performed to ensure that the services provided by calibration laboratories to end-users follow internationally accepted standards. Ionizing radiation dosimetry intercomparisons are usually of two types – postal thermoluminescent dosimeter intercomparisons and ionization chamber calibration intercomparisons. In this paper, both types of intercomparisons are discussed together with the results of 7 years of participation in such intercomparisons. Finally, several discrepancies were discovered as a result of intercomparisons analysis and the resolution of the discrepancies was discussed.",
publisher = "Beograd : Univerzitet u Beogradu, Institut za nuklearne nauke "Vinča", Beograd : Društvo za zaštitu od zračenja Srbije i Crne Gore",
journal = "28. симпозијум ДЗЗСЦГ : зборник радова",
title = "Interkomparacije kao važan element osiguranja kvaliteta u metrologiji jonizujućeg zračenja, Intercomparisons as an important element of quality assurance in metrology of ionising radiation",
pages = "572-576",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12346"
}
Živanović, M., Lazarević, Đ., Ciraj-Bjelac, O., Stanković, S., Ćeklić, S. M.,& Karadžić, K.. (2015). Interkomparacije kao važan element osiguranja kvaliteta u metrologiji jonizujućeg zračenja. in 28. симпозијум ДЗЗСЦГ : зборник радова
Beograd : Univerzitet u Beogradu, Institut za nuklearne nauke "Vinča"., 572-576.
https://hdl.handle.net/21.15107/rcub_vinar_12346
Živanović M, Lazarević Đ, Ciraj-Bjelac O, Stanković S, Ćeklić SM, Karadžić K. Interkomparacije kao važan element osiguranja kvaliteta u metrologiji jonizujućeg zračenja. in 28. симпозијум ДЗЗСЦГ : зборник радова. 2015;:572-576.
https://hdl.handle.net/21.15107/rcub_vinar_12346 .
Živanović, Miloš, Lazarević, Đorđe, Ciraj-Bjelac, Olivera, Stanković, Srboljub, Ćeklić, Sandra M., Karadžić, Katarina, "Interkomparacije kao važan element osiguranja kvaliteta u metrologiji jonizujućeg zračenja" in 28. симпозијум ДЗЗСЦГ : зборник радова (2015):572-576,
https://hdl.handle.net/21.15107/rcub_vinar_12346 .

Intercomparisons as An Important Element of Quality Assurance in Metrology of Ionising Radiation

Živanović, Miloš Z.; Lazarević, Đorđe R.; Ciraj-Bjelac, Olivera; Stanković, Srboljub J.; Ćeklić, Sandra; Karadžić, Katarina

(2015)

TY  - JOUR
AU  - Živanović, Miloš Z.
AU  - Lazarević, Đorđe R.
AU  - Ciraj-Bjelac, Olivera
AU  - Stanković, Srboljub J.
AU  - Ćeklić, Sandra
AU  - Karadžić, Katarina
PY  - 2015
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/794
AB  - Intercomparisons are important activities performed to ensure that the services provided by calibration laboratories to end-users follow internationally accepted standards. Ionizing radiation dosimetry intercomparisons are usually of two types - postal thermoluminescent dosimeter intercomparisons and ionization chamber calibration intercomparisons. In this paper, both types of intercomparisons are analysed together with the results of seven years of participation in such intercomparisons. Several discrepancies were discovered as a result of intercomparisons analysis and the resolution of the discrepancies was discussed.
T2  - Nuclear technology and radiation protection
T1  - Intercomparisons as An Important Element of Quality Assurance in Metrology of Ionising Radiation
VL  - 30
IS  - 3
SP  - 225
EP  - 231
DO  - 10.2298/NTRP1503225Z
ER  - 
@article{
author = "Živanović, Miloš Z. and Lazarević, Đorđe R. and Ciraj-Bjelac, Olivera and Stanković, Srboljub J. and Ćeklić, Sandra and Karadžić, Katarina",
year = "2015",
abstract = "Intercomparisons are important activities performed to ensure that the services provided by calibration laboratories to end-users follow internationally accepted standards. Ionizing radiation dosimetry intercomparisons are usually of two types - postal thermoluminescent dosimeter intercomparisons and ionization chamber calibration intercomparisons. In this paper, both types of intercomparisons are analysed together with the results of seven years of participation in such intercomparisons. Several discrepancies were discovered as a result of intercomparisons analysis and the resolution of the discrepancies was discussed.",
journal = "Nuclear technology and radiation protection",
title = "Intercomparisons as An Important Element of Quality Assurance in Metrology of Ionising Radiation",
volume = "30",
number = "3",
pages = "225-231",
doi = "10.2298/NTRP1503225Z"
}
Živanović, M. Z., Lazarević, Đ. R., Ciraj-Bjelac, O., Stanković, S. J., Ćeklić, S.,& Karadžić, K.. (2015). Intercomparisons as An Important Element of Quality Assurance in Metrology of Ionising Radiation. in Nuclear technology and radiation protection, 30(3), 225-231.
https://doi.org/10.2298/NTRP1503225Z
Živanović MZ, Lazarević ĐR, Ciraj-Bjelac O, Stanković SJ, Ćeklić S, Karadžić K. Intercomparisons as An Important Element of Quality Assurance in Metrology of Ionising Radiation. in Nuclear technology and radiation protection. 2015;30(3):225-231.
doi:10.2298/NTRP1503225Z .
Živanović, Miloš Z., Lazarević, Đorđe R., Ciraj-Bjelac, Olivera, Stanković, Srboljub J., Ćeklić, Sandra, Karadžić, Katarina, "Intercomparisons as An Important Element of Quality Assurance in Metrology of Ionising Radiation" in Nuclear technology and radiation protection, 30, no. 3 (2015):225-231,
https://doi.org/10.2298/NTRP1503225Z . .
2
1
2

Build-Up PMMA Plate Effect on Calibration of TLD Reader

Kaljević, Jelica; Stanković, Jelena S.; Živanović, Miloš Z.; Ćeklić, Sandra; Lazarević, Đorđe R.

(2015)

TY  - CONF
AU  - Kaljević, Jelica
AU  - Stanković, Jelena S.
AU  - Živanović, Miloš Z.
AU  - Ćeklić, Sandra
AU  - Lazarević, Đorđe R.
PY  - 2015
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7121
AB  - The routine monitoring of the occupationally exposed individuals constitutes an integral part of radiation protection program implemented at the Vinca Institute of Nuclear Sciences (INNV). The Individual monitoring service (IMS) at the INNV, accredited according to quality standard EN ISO/IEC 17025, is using Harshaw 6600 Plus automatic reader and thermoluminescent dosimeters (TLD) from two manufacturers (Harshaw, RadPro international GmbH). Working procedures are implemented according to Technical Recommendations for Monitoring Individuals Occupationally Exposed to External Radiation, RP 160 (European Commission, 2009). Among general consideration, RP 160 is suggesting that routine calibration of dosimetry system should be performed taking into consideration secondary charged particle equilibrium. As TLD system in use at IMS INNV comprises of TLD reader and of TLD cards, this consideration should be applied in both cases: when the reader and the TLD cards are being calibrated. During reader calibration, secondary charged particle equilibrium can be ensured using build-up PMMA plate of certain thickness placed in front of dosimeters. In this paper, influence of the build-up plate on reader calibration is being analyzed. This influence is observed through changes in reader calibration factor (RCF). RCF values obtained during reader calibration procedure with and without 2 mm thick build-up plate are presented. Exposures of whole body TLDs placed on slab phantom were done with Cs-137 radiation source located at Secondary Standard Dosimetry Laboratory (SSDL) at INNV. TLDs from both manufacturers had 2 detectors for measuring the dose equivalent at the depths of 10 mm and 0.07 mm. TLD reader was calibrated to measure effective dose in terms of Hp(10) and local skin dose in terms of Hp(0.07). RCF values for detectors measuring Hp(10), from both manufacturers, when irradiated without the plate were around 5% higher than RCF values obtained when irradiations were done with the plate. Values of RCFs for detectors measuring Hp(0.07) were around 1% higher when the plate had not been used. As RCF value is inversely proportional to measured dose, reader calibration without build-up plate, in terms of Hp(10), would lead to underestimated dose values. The observed RCF deviation of Hp(0.07) detector is regarded as consequence of exposure conditions uncertainties. In conclusion, if a constant geometry and constant operational conditions of TLDs are achieved, the only part of the TLD system that is not stable for a long time period is the TLD reader. To avoid inaccurate results, RCF should be orderly checked and reader calibration should be done according to widely accepted standards, currently in effect.
C3  - RAD Conference Proceedings
T1  - Build-Up PMMA Plate Effect on Calibration of TLD Reader
SP  - 147
EP  - 150
UR  - https://hdl.handle.net/21.15107/rcub_vinar_7121
ER  - 
@conference{
author = "Kaljević, Jelica and Stanković, Jelena S. and Živanović, Miloš Z. and Ćeklić, Sandra and Lazarević, Đorđe R.",
year = "2015",
abstract = "The routine monitoring of the occupationally exposed individuals constitutes an integral part of radiation protection program implemented at the Vinca Institute of Nuclear Sciences (INNV). The Individual monitoring service (IMS) at the INNV, accredited according to quality standard EN ISO/IEC 17025, is using Harshaw 6600 Plus automatic reader and thermoluminescent dosimeters (TLD) from two manufacturers (Harshaw, RadPro international GmbH). Working procedures are implemented according to Technical Recommendations for Monitoring Individuals Occupationally Exposed to External Radiation, RP 160 (European Commission, 2009). Among general consideration, RP 160 is suggesting that routine calibration of dosimetry system should be performed taking into consideration secondary charged particle equilibrium. As TLD system in use at IMS INNV comprises of TLD reader and of TLD cards, this consideration should be applied in both cases: when the reader and the TLD cards are being calibrated. During reader calibration, secondary charged particle equilibrium can be ensured using build-up PMMA plate of certain thickness placed in front of dosimeters. In this paper, influence of the build-up plate on reader calibration is being analyzed. This influence is observed through changes in reader calibration factor (RCF). RCF values obtained during reader calibration procedure with and without 2 mm thick build-up plate are presented. Exposures of whole body TLDs placed on slab phantom were done with Cs-137 radiation source located at Secondary Standard Dosimetry Laboratory (SSDL) at INNV. TLDs from both manufacturers had 2 detectors for measuring the dose equivalent at the depths of 10 mm and 0.07 mm. TLD reader was calibrated to measure effective dose in terms of Hp(10) and local skin dose in terms of Hp(0.07). RCF values for detectors measuring Hp(10), from both manufacturers, when irradiated without the plate were around 5% higher than RCF values obtained when irradiations were done with the plate. Values of RCFs for detectors measuring Hp(0.07) were around 1% higher when the plate had not been used. As RCF value is inversely proportional to measured dose, reader calibration without build-up plate, in terms of Hp(10), would lead to underestimated dose values. The observed RCF deviation of Hp(0.07) detector is regarded as consequence of exposure conditions uncertainties. In conclusion, if a constant geometry and constant operational conditions of TLDs are achieved, the only part of the TLD system that is not stable for a long time period is the TLD reader. To avoid inaccurate results, RCF should be orderly checked and reader calibration should be done according to widely accepted standards, currently in effect.",
journal = "RAD Conference Proceedings",
title = "Build-Up PMMA Plate Effect on Calibration of TLD Reader",
pages = "147-150",
url = "https://hdl.handle.net/21.15107/rcub_vinar_7121"
}
Kaljević, J., Stanković, J. S., Živanović, M. Z., Ćeklić, S.,& Lazarević, Đ. R.. (2015). Build-Up PMMA Plate Effect on Calibration of TLD Reader. in RAD Conference Proceedings, 147-150.
https://hdl.handle.net/21.15107/rcub_vinar_7121
Kaljević J, Stanković JS, Živanović MZ, Ćeklić S, Lazarević ĐR. Build-Up PMMA Plate Effect on Calibration of TLD Reader. in RAD Conference Proceedings. 2015;:147-150.
https://hdl.handle.net/21.15107/rcub_vinar_7121 .
Kaljević, Jelica, Stanković, Jelena S., Živanović, Miloš Z., Ćeklić, Sandra, Lazarević, Đorđe R., "Build-Up PMMA Plate Effect on Calibration of TLD Reader" in RAD Conference Proceedings (2015):147-150,
https://hdl.handle.net/21.15107/rcub_vinar_7121 .

Assessment of Occupational Dose in Fluoroscopy Procedures When Individual Monitoring Is Not Utilized

Ciraj-Bjelac, Olivera; Aranđić, Danijela; Božović, Predrag; Ćeklić, Sandra; Stanković, Jelena S.; Lazarević, Đorđe R.

(2015)

TY  - CONF
AU  - Ciraj-Bjelac, Olivera
AU  - Aranđić, Danijela
AU  - Božović, Predrag
AU  - Ćeklić, Sandra
AU  - Stanković, Jelena S.
AU  - Lazarević, Đorđe R.
PY  - 2015
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7123
AB  - Fluoroscopy procedures may lead to increased radiation exposure of radiologists and other staff members. The objective of the study is to assess whole body radiation doses and doses to the eye in fluoroscopy procedures, based on measurements that allow for estimates of occupational doses when personal dosimeters have not been used. Four geometrical configurations were considered: overcouch x-ray tube with and without table mounted lead rubber curtains in place, undercouch x-ray tube with horizontal x-ray beam and undercouch x-ray tube with vertical x-ray beam. The doses were estimated using distribution of the scattered radiation and typical workload, as well as the pattern of used of protective tools. Estimated effective dose was in the range from few to 60 mu Sv per procedure for radiologist, and from few to 20 mu Sv per procedure for radiographer, depending on the geometrical configuration and level of personal protection. Corresponding unprotected eye doses were estimated to be in the range 0.03 - 2.8 mSv per procedure for radiologist and 0.02-0.78 mSv for radiographer. The presented results allowed for realistic estimations of the occupational whole body dose and dose to the eyes from the workload of the staff members and from the level of use of radiation protection tools when personal dosimeters have not been regularly used.
C3  - RAD Conference Proceedings
T1  - Assessment of Occupational Dose in Fluoroscopy Procedures When Individual Monitoring Is Not Utilized
SP  - 195
EP  - 198
UR  - https://hdl.handle.net/21.15107/rcub_vinar_7123
ER  - 
@conference{
author = "Ciraj-Bjelac, Olivera and Aranđić, Danijela and Božović, Predrag and Ćeklić, Sandra and Stanković, Jelena S. and Lazarević, Đorđe R.",
year = "2015",
abstract = "Fluoroscopy procedures may lead to increased radiation exposure of radiologists and other staff members. The objective of the study is to assess whole body radiation doses and doses to the eye in fluoroscopy procedures, based on measurements that allow for estimates of occupational doses when personal dosimeters have not been used. Four geometrical configurations were considered: overcouch x-ray tube with and without table mounted lead rubber curtains in place, undercouch x-ray tube with horizontal x-ray beam and undercouch x-ray tube with vertical x-ray beam. The doses were estimated using distribution of the scattered radiation and typical workload, as well as the pattern of used of protective tools. Estimated effective dose was in the range from few to 60 mu Sv per procedure for radiologist, and from few to 20 mu Sv per procedure for radiographer, depending on the geometrical configuration and level of personal protection. Corresponding unprotected eye doses were estimated to be in the range 0.03 - 2.8 mSv per procedure for radiologist and 0.02-0.78 mSv for radiographer. The presented results allowed for realistic estimations of the occupational whole body dose and dose to the eyes from the workload of the staff members and from the level of use of radiation protection tools when personal dosimeters have not been regularly used.",
journal = "RAD Conference Proceedings",
title = "Assessment of Occupational Dose in Fluoroscopy Procedures When Individual Monitoring Is Not Utilized",
pages = "195-198",
url = "https://hdl.handle.net/21.15107/rcub_vinar_7123"
}
Ciraj-Bjelac, O., Aranđić, D., Božović, P., Ćeklić, S., Stanković, J. S.,& Lazarević, Đ. R.. (2015). Assessment of Occupational Dose in Fluoroscopy Procedures When Individual Monitoring Is Not Utilized. in RAD Conference Proceedings, 195-198.
https://hdl.handle.net/21.15107/rcub_vinar_7123
Ciraj-Bjelac O, Aranđić D, Božović P, Ćeklić S, Stanković JS, Lazarević ĐR. Assessment of Occupational Dose in Fluoroscopy Procedures When Individual Monitoring Is Not Utilized. in RAD Conference Proceedings. 2015;:195-198.
https://hdl.handle.net/21.15107/rcub_vinar_7123 .
Ciraj-Bjelac, Olivera, Aranđić, Danijela, Božović, Predrag, Ćeklić, Sandra, Stanković, Jelena S., Lazarević, Đorđe R., "Assessment of Occupational Dose in Fluoroscopy Procedures When Individual Monitoring Is Not Utilized" in RAD Conference Proceedings (2015):195-198,
https://hdl.handle.net/21.15107/rcub_vinar_7123 .

Radiation Doses in Adult Computed Tomography Practice in Serbia: Initial Results

Aranđić, Danijela; Ciraj-Bjelac, Olivera; Hadnadjev, Darka; Stojanovic, Sanja; Božović, Predrag; Ćeklić, Sandra; Lazarević, Đorđe R.

(2014)

TY  - JOUR
AU  - Aranđić, Danijela
AU  - Ciraj-Bjelac, Olivera
AU  - Hadnadjev, Darka
AU  - Stojanovic, Sanja
AU  - Božović, Predrag
AU  - Ćeklić, Sandra
AU  - Lazarević, Đorđe R.
PY  - 2014
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7048
AB  - This work presents initial data on radiation doses in adult computed tomography (CT) in Serbia. Data were collected in terms of CT dose index (CTDIvol) and dose length product (DLP) values for head, chest and abdomen examination. The range of CTDIvol values was found to be 53-98, 11-34 and 8.5-227 mGy whereas for DLP was 803-1066, 350-845 and 1066-3078 mGy cm(-1) for head, chest and abdomen examination, respectively. Except for abdomen on one CT unit, all estimated values were in line with the reported data. This work also presents simple method on how to reduce radiation doses when scanning head. Using axial (step-and-shot) instead of helical mode and decreasing tube current-time product leads to significant dose reduction. CTDIvol was decreased by 20 % whereas DLP was reduced for a factor 2.
T2  - Radiation Protection Dosimetry
T1  - Radiation Doses in Adult Computed Tomography Practice in Serbia: Initial Results
VL  - 162
IS  - 1-2
SP  - 135
EP  - 138
DO  - 10.1093/rpd/ncu245
ER  - 
@article{
author = "Aranđić, Danijela and Ciraj-Bjelac, Olivera and Hadnadjev, Darka and Stojanovic, Sanja and Božović, Predrag and Ćeklić, Sandra and Lazarević, Đorđe R.",
year = "2014",
abstract = "This work presents initial data on radiation doses in adult computed tomography (CT) in Serbia. Data were collected in terms of CT dose index (CTDIvol) and dose length product (DLP) values for head, chest and abdomen examination. The range of CTDIvol values was found to be 53-98, 11-34 and 8.5-227 mGy whereas for DLP was 803-1066, 350-845 and 1066-3078 mGy cm(-1) for head, chest and abdomen examination, respectively. Except for abdomen on one CT unit, all estimated values were in line with the reported data. This work also presents simple method on how to reduce radiation doses when scanning head. Using axial (step-and-shot) instead of helical mode and decreasing tube current-time product leads to significant dose reduction. CTDIvol was decreased by 20 % whereas DLP was reduced for a factor 2.",
journal = "Radiation Protection Dosimetry",
title = "Radiation Doses in Adult Computed Tomography Practice in Serbia: Initial Results",
volume = "162",
number = "1-2",
pages = "135-138",
doi = "10.1093/rpd/ncu245"
}
Aranđić, D., Ciraj-Bjelac, O., Hadnadjev, D., Stojanovic, S., Božović, P., Ćeklić, S.,& Lazarević, Đ. R.. (2014). Radiation Doses in Adult Computed Tomography Practice in Serbia: Initial Results. in Radiation Protection Dosimetry, 162(1-2), 135-138.
https://doi.org/10.1093/rpd/ncu245
Aranđić D, Ciraj-Bjelac O, Hadnadjev D, Stojanovic S, Božović P, Ćeklić S, Lazarević ĐR. Radiation Doses in Adult Computed Tomography Practice in Serbia: Initial Results. in Radiation Protection Dosimetry. 2014;162(1-2):135-138.
doi:10.1093/rpd/ncu245 .
Aranđić, Danijela, Ciraj-Bjelac, Olivera, Hadnadjev, Darka, Stojanovic, Sanja, Božović, Predrag, Ćeklić, Sandra, Lazarević, Đorđe R., "Radiation Doses in Adult Computed Tomography Practice in Serbia: Initial Results" in Radiation Protection Dosimetry, 162, no. 1-2 (2014):135-138,
https://doi.org/10.1093/rpd/ncu245 . .
1
2
2

Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields

Ćeklić, Sandra; Aranđić, Danijela; Živanović, Miloš Z.; Ciraj-Bjelac, Olivera; Lazarević, Đorđe R.

(2014)

TY  - JOUR
AU  - Ćeklić, Sandra
AU  - Aranđić, Danijela
AU  - Živanović, Miloš Z.
AU  - Ciraj-Bjelac, Olivera
AU  - Lazarević, Đorđe R.
PY  - 2014
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7049
AB  - The aim of this work was to investigate the different types of radiation detectors commonly used for radiation protection purposes as survey meters. The study was performed on survey meters that use different detectors as ionisation chamber, Geiger Mueller (GM) counter and scintillation detector. For each survey meter, energy dependence and angular response in X-and gamma-radiation fields was tested. The following commercially available survey meters were investigated: ionisation chambers Victoreen 451P, Babyline 31 and VA-J-15A, Geiger counter MRK-M87, 6150 AD6 and FAG FH 40F2 and scintillation counter 6150 ADB. As a source of gamma radiation, Cs-137 and Co-60 were used whereas X-ray radiation fields were generated using an X-ray unit. The radiation characteristics of the survey meters were mostly in compliance with references estimated by standard IEC 1017-2. However, some of them showed larger deviation at lower energies. GM counters exhibit strong energy dependence for low-energy photons.
T2  - Radiation Protection Dosimetry
T1  - Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields
VL  - 162
IS  - 1-2
SP  - 139
EP  - 143
DO  - 10.1093/rpd/ncu246
ER  - 
@article{
author = "Ćeklić, Sandra and Aranđić, Danijela and Živanović, Miloš Z. and Ciraj-Bjelac, Olivera and Lazarević, Đorđe R.",
year = "2014",
abstract = "The aim of this work was to investigate the different types of radiation detectors commonly used for radiation protection purposes as survey meters. The study was performed on survey meters that use different detectors as ionisation chamber, Geiger Mueller (GM) counter and scintillation detector. For each survey meter, energy dependence and angular response in X-and gamma-radiation fields was tested. The following commercially available survey meters were investigated: ionisation chambers Victoreen 451P, Babyline 31 and VA-J-15A, Geiger counter MRK-M87, 6150 AD6 and FAG FH 40F2 and scintillation counter 6150 ADB. As a source of gamma radiation, Cs-137 and Co-60 were used whereas X-ray radiation fields were generated using an X-ray unit. The radiation characteristics of the survey meters were mostly in compliance with references estimated by standard IEC 1017-2. However, some of them showed larger deviation at lower energies. GM counters exhibit strong energy dependence for low-energy photons.",
journal = "Radiation Protection Dosimetry",
title = "Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields",
volume = "162",
number = "1-2",
pages = "139-143",
doi = "10.1093/rpd/ncu246"
}
Ćeklić, S., Aranđić, D., Živanović, M. Z., Ciraj-Bjelac, O.,& Lazarević, Đ. R.. (2014). Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields. in Radiation Protection Dosimetry, 162(1-2), 139-143.
https://doi.org/10.1093/rpd/ncu246
Ćeklić S, Aranđić D, Živanović MZ, Ciraj-Bjelac O, Lazarević ĐR. Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields. in Radiation Protection Dosimetry. 2014;162(1-2):139-143.
doi:10.1093/rpd/ncu246 .
Ćeklić, Sandra, Aranđić, Danijela, Živanović, Miloš Z., Ciraj-Bjelac, Olivera, Lazarević, Đorđe R., "Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields" in Radiation Protection Dosimetry, 162, no. 1-2 (2014):139-143,
https://doi.org/10.1093/rpd/ncu246 . .
9
5
7