Eric, Olivera

Link to this page

Authority KeyName Variants
60f5c0fc-a731-4751-a857-290e902f6ada
  • Eric, Olivera (1)
Projects
No records found.

Author's Bibliography

Microstructure and fracture of alloyed austempered ductile iron

Eric, Olivera; Rajnović, Dragan; Zec, Slavica; Siđanin, Leposava; Jovanović, Milan T.

(2006)

TY  - JOUR
AU  - Eric, Olivera
AU  - Rajnović, Dragan
AU  - Zec, Slavica
AU  - Siđanin, Leposava
AU  - Jovanović, Milan T.
PY  - 2006
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/3138
AB  - An investigation has been conducted on two austempered ductile irons alloyed with Cu and Cu+Ni, austenitized at 900 degrees C and austempered at 350 degrees C. The microstructure and fracture mode developed through these treatments have been identified by means of light and scanning electron microscopy and X-ray diffraction analysis. Impact energy measurements were performed on un-notched Charpy specimens. The maximum value of retained austenite volume fraction observed in the material alloyed with Cu+Ni was higher than in that alloyed with Cu austenitized and austempered under the same conditions. This led to the material alloyed with Cu+Ni having higher impact energy and substantial plastic deformation. (c) 2006 Elsevier Inc. All rights reserved.
T2  - Materials Characterization
T1  - Microstructure and fracture of alloyed austempered ductile iron
VL  - 57
IS  - 4-5
SP  - 211
EP  - 217
DO  - 10.1016/j.matchar.2006.01.014
ER  - 
@article{
author = "Eric, Olivera and Rajnović, Dragan and Zec, Slavica and Siđanin, Leposava and Jovanović, Milan T.",
year = "2006",
abstract = "An investigation has been conducted on two austempered ductile irons alloyed with Cu and Cu+Ni, austenitized at 900 degrees C and austempered at 350 degrees C. The microstructure and fracture mode developed through these treatments have been identified by means of light and scanning electron microscopy and X-ray diffraction analysis. Impact energy measurements were performed on un-notched Charpy specimens. The maximum value of retained austenite volume fraction observed in the material alloyed with Cu+Ni was higher than in that alloyed with Cu austenitized and austempered under the same conditions. This led to the material alloyed with Cu+Ni having higher impact energy and substantial plastic deformation. (c) 2006 Elsevier Inc. All rights reserved.",
journal = "Materials Characterization",
title = "Microstructure and fracture of alloyed austempered ductile iron",
volume = "57",
number = "4-5",
pages = "211-217",
doi = "10.1016/j.matchar.2006.01.014"
}
Eric, O., Rajnović, D., Zec, S., Siđanin, L.,& Jovanović, M. T.. (2006). Microstructure and fracture of alloyed austempered ductile iron. in Materials Characterization, 57(4-5), 211-217.
https://doi.org/10.1016/j.matchar.2006.01.014
Eric O, Rajnović D, Zec S, Siđanin L, Jovanović MT. Microstructure and fracture of alloyed austempered ductile iron. in Materials Characterization. 2006;57(4-5):211-217.
doi:10.1016/j.matchar.2006.01.014 .
Eric, Olivera, Rajnović, Dragan, Zec, Slavica, Siđanin, Leposava, Jovanović, Milan T., "Microstructure and fracture of alloyed austempered ductile iron" in Materials Characterization, 57, no. 4-5 (2006):211-217,
https://doi.org/10.1016/j.matchar.2006.01.014 . .
58
56
71