Jovic, Aleksandar

Link to this page

Authority KeyName Variants
0f73a743-51ab-4f93-8e65-43d035978f96
  • Jovic, Aleksandar (1)
Projects

Author's Bibliography

Composite zeolite/carbonized polyaniline electrodes for p-nitrophenol sensing

Jovic, Aleksandar; Đorđević, Aleksandar R.; Čebela, Maria; Stojković-Simatović, Ivana; Hercigonja, Radmila V.; Šljukić, Biljana

(2016)

TY  - JOUR
AU  - Jovic, Aleksandar
AU  - Đorđević, Aleksandar R.
AU  - Čebela, Maria
AU  - Stojković-Simatović, Ivana
AU  - Hercigonja, Radmila V.
AU  - Šljukić, Biljana
PY  - 2016
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/1263
AB  - Electrodes based on composites of zeolites with carbonized polyaniline prepared in the presence of 5-sulfosalicylic acid are evaluated for both qualitative and quantitative determination of phenols in aqueous solutions. Zeolites used included NaX and NaY, as well as their transition metal (Mn and Cu) cation-exchanged forms, and they were all characterized usingXRPD, FTIR and SEM. Cyclic voltammetry was used to study composites electrochemical response in the presence of p-nitrophenol, phenol and 5-aminophenol in acidic, neutral and al- kaline media. Linear dependence of current on p-nitrophenol concentration in acidic media was obtained in 0.11 mM concentration range. The comparative evaluation of the electrochemical response of NaX/carbonized polyaniline composite and its individual components revealed significantly lower limit of detection obtained using composite electrode (1.27 mu M) compared to that obtained using pure zeolite (135 mu M) or pure carbonized polyaniline (94.5 mu M) electrode. Composite electrode gave response to p-nitrophenol presence in neutral media as well, but it quickly disappeared with continuous scanning, while no clear response could be seen in highly alkaline media. Thus, this work demonstrates benefits of using novel composite based on zeolites and carbonized polyaniline for sensing of phenols in acidic aqueous solutions. (C) 2016 Elsevier B.V. All rights reserved.
T2  - Journal of Electroanalytical Chemistry
T1  - Composite zeolite/carbonized polyaniline electrodes for p-nitrophenol sensing
VL  - 778
SP  - 137
EP  - 147
DO  - 10.1016/j.jelechem.2016.08.025
ER  - 
@article{
author = "Jovic, Aleksandar and Đorđević, Aleksandar R. and Čebela, Maria and Stojković-Simatović, Ivana and Hercigonja, Radmila V. and Šljukić, Biljana",
year = "2016",
abstract = "Electrodes based on composites of zeolites with carbonized polyaniline prepared in the presence of 5-sulfosalicylic acid are evaluated for both qualitative and quantitative determination of phenols in aqueous solutions. Zeolites used included NaX and NaY, as well as their transition metal (Mn and Cu) cation-exchanged forms, and they were all characterized usingXRPD, FTIR and SEM. Cyclic voltammetry was used to study composites electrochemical response in the presence of p-nitrophenol, phenol and 5-aminophenol in acidic, neutral and al- kaline media. Linear dependence of current on p-nitrophenol concentration in acidic media was obtained in 0.11 mM concentration range. The comparative evaluation of the electrochemical response of NaX/carbonized polyaniline composite and its individual components revealed significantly lower limit of detection obtained using composite electrode (1.27 mu M) compared to that obtained using pure zeolite (135 mu M) or pure carbonized polyaniline (94.5 mu M) electrode. Composite electrode gave response to p-nitrophenol presence in neutral media as well, but it quickly disappeared with continuous scanning, while no clear response could be seen in highly alkaline media. Thus, this work demonstrates benefits of using novel composite based on zeolites and carbonized polyaniline for sensing of phenols in acidic aqueous solutions. (C) 2016 Elsevier B.V. All rights reserved.",
journal = "Journal of Electroanalytical Chemistry",
title = "Composite zeolite/carbonized polyaniline electrodes for p-nitrophenol sensing",
volume = "778",
pages = "137-147",
doi = "10.1016/j.jelechem.2016.08.025"
}
Jovic, A., Đorđević, A. R., Čebela, M., Stojković-Simatović, I., Hercigonja, R. V.,& Šljukić, B.. (2016). Composite zeolite/carbonized polyaniline electrodes for p-nitrophenol sensing. in Journal of Electroanalytical Chemistry, 778, 137-147.
https://doi.org/10.1016/j.jelechem.2016.08.025
Jovic A, Đorđević AR, Čebela M, Stojković-Simatović I, Hercigonja RV, Šljukić B. Composite zeolite/carbonized polyaniline electrodes for p-nitrophenol sensing. in Journal of Electroanalytical Chemistry. 2016;778:137-147.
doi:10.1016/j.jelechem.2016.08.025 .
Jovic, Aleksandar, Đorđević, Aleksandar R., Čebela, Maria, Stojković-Simatović, Ivana, Hercigonja, Radmila V., Šljukić, Biljana, "Composite zeolite/carbonized polyaniline electrodes for p-nitrophenol sensing" in Journal of Electroanalytical Chemistry, 778 (2016):137-147,
https://doi.org/10.1016/j.jelechem.2016.08.025 . .
14
13
15