Vukcevic, Miodrag

Link to this page

Authority KeyName Variants
c829b692-25ef-4615-bf56-a74bd72db8cc
  • Vukcevic, Miodrag (3)
Projects

Author's Bibliography

A New Method for Respiratory-Volume Monitoring Based on Long-Period Fibre Gratings

Petrovic, Marija; Petrović, Jovana S.; Simic, Goran; Ilic, Igor; Daničić, Aleksandar; Vukcevic, Miodrag; Bojović, Boško; Hadžievski, Ljupčo; Allsop, Thomas P.; Webb, David J.

(2013)

TY  - CONF
AU  - Petrovic, Marija
AU  - Petrović, Jovana S.
AU  - Simic, Goran
AU  - Ilic, Igor
AU  - Daničić, Aleksandar
AU  - Vukcevic, Miodrag
AU  - Bojović, Boško
AU  - Hadžievski, Ljupčo
AU  - Allsop, Thomas P.
AU  - Webb, David J.
PY  - 2013
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7036
AB  - Respiratory-volume monitoring is an indispensable part of mechanical ventilation. Here we present a new method of the respiratory-volume measurement based on a single fibre-optical long-period sensor of bending and the correlation between torso curvature and lung volume. Unlike the commonly used air-flow based measurement methods the proposed sensor is drift-free and immune to air-leaks. In the paper, we explain the working principle of sensors, a two-step calibration-test measurement procedure and present results that establish a linear correlation between the change in the local thorax curvature and the change of the lung volume. We also discuss the advantages and limitations of these sensors with respect to the current standards.
T1  - A New Method for Respiratory-Volume Monitoring Based on Long-Period Fibre Gratings
SP  - 2660
EP  - 2663
UR  - https://hdl.handle.net/21.15107/rcub_vinar_7036
ER  - 
@conference{
author = "Petrovic, Marija and Petrović, Jovana S. and Simic, Goran and Ilic, Igor and Daničić, Aleksandar and Vukcevic, Miodrag and Bojović, Boško and Hadžievski, Ljupčo and Allsop, Thomas P. and Webb, David J.",
year = "2013",
abstract = "Respiratory-volume monitoring is an indispensable part of mechanical ventilation. Here we present a new method of the respiratory-volume measurement based on a single fibre-optical long-period sensor of bending and the correlation between torso curvature and lung volume. Unlike the commonly used air-flow based measurement methods the proposed sensor is drift-free and immune to air-leaks. In the paper, we explain the working principle of sensors, a two-step calibration-test measurement procedure and present results that establish a linear correlation between the change in the local thorax curvature and the change of the lung volume. We also discuss the advantages and limitations of these sensors with respect to the current standards.",
title = "A New Method for Respiratory-Volume Monitoring Based on Long-Period Fibre Gratings",
pages = "2660-2663",
url = "https://hdl.handle.net/21.15107/rcub_vinar_7036"
}
Petrovic, M., Petrović, J. S., Simic, G., Ilic, I., Daničić, A., Vukcevic, M., Bojović, B., Hadžievski, L., Allsop, T. P.,& Webb, D. J.. (2013). A New Method for Respiratory-Volume Monitoring Based on Long-Period Fibre Gratings. , 2660-2663.
https://hdl.handle.net/21.15107/rcub_vinar_7036
Petrovic M, Petrović JS, Simic G, Ilic I, Daničić A, Vukcevic M, Bojović B, Hadžievski L, Allsop TP, Webb DJ. A New Method for Respiratory-Volume Monitoring Based on Long-Period Fibre Gratings. 2013;:2660-2663.
https://hdl.handle.net/21.15107/rcub_vinar_7036 .
Petrovic, Marija, Petrović, Jovana S., Simic, Goran, Ilic, Igor, Daničić, Aleksandar, Vukcevic, Miodrag, Bojović, Boško, Hadžievski, Ljupčo, Allsop, Thomas P., Webb, David J., "A New Method for Respiratory-Volume Monitoring Based on Long-Period Fibre Gratings" (2013):2660-2663,
https://hdl.handle.net/21.15107/rcub_vinar_7036 .
3

An early non-invasive detection of the patient inspiratory effort for patient-ventilator synchronization

Vukcevic, Miodrag; Bojović, Boško; Petrović, Marija; Simic, Goran; Daničić, Aleksandar; Petrović, Jovana S.; Hadžievski, Ljupčo

(2013)

TY  - CONF
AU  - Vukcevic, Miodrag
AU  - Bojović, Boško
AU  - Petrović, Marija
AU  - Simic, Goran
AU  - Daničić, Aleksandar
AU  - Petrović, Jovana S.
AU  - Hadžievski, Ljupčo
PY  - 2013
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/2740
C3  - European Respiratory Journal
T1  - An early non-invasive detection of the patient inspiratory effort for patient-ventilator synchronization
VL  - 42
UR  - https://hdl.handle.net/21.15107/rcub_vinar_2740
ER  - 
@conference{
author = "Vukcevic, Miodrag and Bojović, Boško and Petrović, Marija and Simic, Goran and Daničić, Aleksandar and Petrović, Jovana S. and Hadžievski, Ljupčo",
year = "2013",
journal = "European Respiratory Journal",
title = "An early non-invasive detection of the patient inspiratory effort for patient-ventilator synchronization",
volume = "42",
url = "https://hdl.handle.net/21.15107/rcub_vinar_2740"
}
Vukcevic, M., Bojović, B., Petrović, M., Simic, G., Daničić, A., Petrović, J. S.,& Hadžievski, L.. (2013). An early non-invasive detection of the patient inspiratory effort for patient-ventilator synchronization. in European Respiratory Journal, 42.
https://hdl.handle.net/21.15107/rcub_vinar_2740
Vukcevic M, Bojović B, Petrović M, Simic G, Daničić A, Petrović JS, Hadžievski L. An early non-invasive detection of the patient inspiratory effort for patient-ventilator synchronization. in European Respiratory Journal. 2013;42.
https://hdl.handle.net/21.15107/rcub_vinar_2740 .
Vukcevic, Miodrag, Bojović, Boško, Petrović, Marija, Simic, Goran, Daničić, Aleksandar, Petrović, Jovana S., Hadžievski, Ljupčo, "An early non-invasive detection of the patient inspiratory effort for patient-ventilator synchronization" in European Respiratory Journal, 42 (2013),
https://hdl.handle.net/21.15107/rcub_vinar_2740 .

A non-invasive LPG (long-period grating) fiber-optic sensing method for respiratory volume monitoring

Vukcevic, Miodrag; Bojović, Boško; Petrović, Marija; Petrović, Jovana S.; Daničić, Aleksandar; Simic, Goran; Hadžievski, Ljupčo

(2013)

TY  - CONF
AU  - Vukcevic, Miodrag
AU  - Bojović, Boško
AU  - Petrović, Marija
AU  - Petrović, Jovana S.
AU  - Daničić, Aleksandar
AU  - Simic, Goran
AU  - Hadžievski, Ljupčo
PY  - 2013
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/2741
C3  - European Respiratory Journal
T1  - A non-invasive LPG (long-period grating) fiber-optic sensing method for respiratory volume monitoring
VL  - 42
UR  - https://hdl.handle.net/21.15107/rcub_vinar_2741
ER  - 
@conference{
author = "Vukcevic, Miodrag and Bojović, Boško and Petrović, Marija and Petrović, Jovana S. and Daničić, Aleksandar and Simic, Goran and Hadžievski, Ljupčo",
year = "2013",
journal = "European Respiratory Journal",
title = "A non-invasive LPG (long-period grating) fiber-optic sensing method for respiratory volume monitoring",
volume = "42",
url = "https://hdl.handle.net/21.15107/rcub_vinar_2741"
}
Vukcevic, M., Bojović, B., Petrović, M., Petrović, J. S., Daničić, A., Simic, G.,& Hadžievski, L.. (2013). A non-invasive LPG (long-period grating) fiber-optic sensing method for respiratory volume monitoring. in European Respiratory Journal, 42.
https://hdl.handle.net/21.15107/rcub_vinar_2741
Vukcevic M, Bojović B, Petrović M, Petrović JS, Daničić A, Simic G, Hadžievski L. A non-invasive LPG (long-period grating) fiber-optic sensing method for respiratory volume monitoring. in European Respiratory Journal. 2013;42.
https://hdl.handle.net/21.15107/rcub_vinar_2741 .
Vukcevic, Miodrag, Bojović, Boško, Petrović, Marija, Petrović, Jovana S., Daničić, Aleksandar, Simic, Goran, Hadžievski, Ljupčo, "A non-invasive LPG (long-period grating) fiber-optic sensing method for respiratory volume monitoring" in European Respiratory Journal, 42 (2013),
https://hdl.handle.net/21.15107/rcub_vinar_2741 .