Kelleher, Kevin

Link to this page

Authority KeyName Variants
5a194437-080b-45f3-8b00-2043b435a29f
  • Kelleher, Kevin (1)
Projects
No records found.

Author's Bibliography

A Comparison of Retrospective Radon Gas Measurement Techniques Carried Out in the Serbian Spa of Niska Banja

Žunić, Zora S.; Kelleher, Kevin; Čeliković, Igor T.; Ujić, Predrag; Paridaens, Johan; Mc Laughlrn, James P.; Cuknic, Olivera; Milić, Gordana A.; Nikolic, Jugoslav; Simović, Rodoljub

(2009)

TY  - JOUR
AU  - Žunić, Zora S.
AU  - Kelleher, Kevin
AU  - Čeliković, Igor T.
AU  - Ujić, Predrag
AU  - Paridaens, Johan
AU  - Mc Laughlrn, James P.
AU  - Cuknic, Olivera
AU  - Milić, Gordana A.
AU  - Nikolic, Jugoslav
AU  - Simović, Rodoljub
PY  - 2009
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/3798
AB  - Indoor radon retrospective concentrations were obtained and compared using two radon measurement methods. Both methods rely on the measurement of the long-lived radon progeny (210)Pb, collected either on the surfaces (surface trap technique), most frequently glass, or in a volume trap, usually sponge from furniture (volume trap technique). These techniques have been used to retrospectively estimate radon gas concentrations that have existed in dwellings in the past. The work presented here compares the results provided by the surface trap technique devised at the University College of Dublin, Ireland, and the volume trap technique devised at the Scientific Research Center, Mol, Belgium. The field campaign was carried out by the research team of the ECE Laboratory of the Vinca Institute of Nuclear Sciences at the spa of Niska Banja, identified as a region of Serbia with a high indoor radon and ground water radium and radon content.
T2  - Nuclear technology and radiation protection
T1  - A Comparison of Retrospective Radon Gas Measurement Techniques Carried Out in the Serbian Spa of Niska Banja
VL  - 24
IS  - 2
SP  - 94
EP  - 99
DO  - 10.2298/NTRP0902094Z
ER  - 
@article{
author = "Žunić, Zora S. and Kelleher, Kevin and Čeliković, Igor T. and Ujić, Predrag and Paridaens, Johan and Mc Laughlrn, James P. and Cuknic, Olivera and Milić, Gordana A. and Nikolic, Jugoslav and Simović, Rodoljub",
year = "2009",
abstract = "Indoor radon retrospective concentrations were obtained and compared using two radon measurement methods. Both methods rely on the measurement of the long-lived radon progeny (210)Pb, collected either on the surfaces (surface trap technique), most frequently glass, or in a volume trap, usually sponge from furniture (volume trap technique). These techniques have been used to retrospectively estimate radon gas concentrations that have existed in dwellings in the past. The work presented here compares the results provided by the surface trap technique devised at the University College of Dublin, Ireland, and the volume trap technique devised at the Scientific Research Center, Mol, Belgium. The field campaign was carried out by the research team of the ECE Laboratory of the Vinca Institute of Nuclear Sciences at the spa of Niska Banja, identified as a region of Serbia with a high indoor radon and ground water radium and radon content.",
journal = "Nuclear technology and radiation protection",
title = "A Comparison of Retrospective Radon Gas Measurement Techniques Carried Out in the Serbian Spa of Niska Banja",
volume = "24",
number = "2",
pages = "94-99",
doi = "10.2298/NTRP0902094Z"
}
Žunić, Z. S., Kelleher, K., Čeliković, I. T., Ujić, P., Paridaens, J., Mc Laughlrn, J. P., Cuknic, O., Milić, G. A., Nikolic, J.,& Simović, R.. (2009). A Comparison of Retrospective Radon Gas Measurement Techniques Carried Out in the Serbian Spa of Niska Banja. in Nuclear technology and radiation protection, 24(2), 94-99.
https://doi.org/10.2298/NTRP0902094Z
Žunić ZS, Kelleher K, Čeliković IT, Ujić P, Paridaens J, Mc Laughlrn JP, Cuknic O, Milić GA, Nikolic J, Simović R. A Comparison of Retrospective Radon Gas Measurement Techniques Carried Out in the Serbian Spa of Niska Banja. in Nuclear technology and radiation protection. 2009;24(2):94-99.
doi:10.2298/NTRP0902094Z .
Žunić, Zora S., Kelleher, Kevin, Čeliković, Igor T., Ujić, Predrag, Paridaens, Johan, Mc Laughlrn, James P., Cuknic, Olivera, Milić, Gordana A., Nikolic, Jugoslav, Simović, Rodoljub, "A Comparison of Retrospective Radon Gas Measurement Techniques Carried Out in the Serbian Spa of Niska Banja" in Nuclear technology and radiation protection, 24, no. 2 (2009):94-99,
https://doi.org/10.2298/NTRP0902094Z . .
2
7
7