Results of radon CR-39 detectors exposed in schools due two different long-term periods

Stojanovska, Zdenka A.; Boev, Blažo; Žunić, Zora S.; Bossew, Peter; Jovevska, Svetlana

(2016)

TY  - JOUR
AU  - Stojanovska, Zdenka A.
AU  - Boev, Blažo
AU  - Žunić, Zora S.
AU  - Bossew, Peter
AU  - Jovevska, Svetlana
PY  - 2016
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/1251
AB  - The paper deals with the recent survey of indoor radon (Rn) results in schools, where paired CR-39 detectors were simultaneously exposed to different long-term periods, i.e., one detector was exposed during the whole year and the other one in the period of the school year duration. To be able to compare the results obtained, for its analysis, the relative bias and U tests were used. It was found that there are no systematic differences between the results, which points that the exposure of the detector during summer vacations did not affect the estimated average annual radon concentration. The paired results were modelled by a linear function, giving an extremely high coefficient of determination R-2 = 0.99.
T2  - Nukleonika
T1  - Results of radon CR-39 detectors exposed in schools due two different long-term periods
VL  - 61
IS  - 3
SP  - 385
EP  - 389
DO  - 10.1515/nuka-2016-0064
ER  - 
@article{
author = "Stojanovska, Zdenka A. and Boev, Blažo and Žunić, Zora S. and Bossew, Peter and Jovevska, Svetlana",
year = "2016",
abstract = "The paper deals with the recent survey of indoor radon (Rn) results in schools, where paired CR-39 detectors were simultaneously exposed to different long-term periods, i.e., one detector was exposed during the whole year and the other one in the period of the school year duration. To be able to compare the results obtained, for its analysis, the relative bias and U tests were used. It was found that there are no systematic differences between the results, which points that the exposure of the detector during summer vacations did not affect the estimated average annual radon concentration. The paired results were modelled by a linear function, giving an extremely high coefficient of determination R-2 = 0.99.",
journal = "Nukleonika",
title = "Results of radon CR-39 detectors exposed in schools due two different long-term periods",
volume = "61",
number = "3",
pages = "385-389",
doi = "10.1515/nuka-2016-0064"
}
Stojanovska, Z. A., Boev, B., Žunić, Z. S., Bossew, P.,& Jovevska, S.. (2016). Results of radon CR-39 detectors exposed in schools due two different long-term periods. in Nukleonika, 61(3), 385-389.
https://doi.org/10.1515/nuka-2016-0064
Stojanovska ZA, Boev B, Žunić ZS, Bossew P, Jovevska S. Results of radon CR-39 detectors exposed in schools due two different long-term periods. in Nukleonika. 2016;61(3):385-389.
doi:10.1515/nuka-2016-0064 .
Stojanovska, Zdenka A., Boev, Blažo, Žunić, Zora S., Bossew, Peter, Jovevska, Svetlana, "Results of radon CR-39 detectors exposed in schools due two different long-term periods" in Nukleonika, 61, no. 3 (2016):385-389,
https://doi.org/10.1515/nuka-2016-0064 . .
5
6
6