The use of active personal dosemeters in interventional workplaces in hospitals: comparison between active and passive dosemeters worn simultaneously by medical staff

Vanhavere, Filip; Carinou, Eleftheria; Clairand, Isabelle; Ciraj-Bjelac, Olivera; De Monte, F; Domienik-Andrzejewska, J; Ferrari, P; Ginjaume, M; Hršak, Hrvoje; Hupe, O; Knežević, Željka; O’Connor, U; Merce, M Sans; Sarmento, S; Savary, A; Siskoonen, T

(2020)

TY  - JOUR
AU  - Vanhavere, Filip
AU  - Carinou, Eleftheria
AU  - Clairand, Isabelle
AU  - Ciraj-Bjelac, Olivera
AU  - De Monte, F
AU  - Domienik-Andrzejewska, J
AU  - Ferrari, P
AU  - Ginjaume, M
AU  - Hršak, Hrvoje
AU  - Hupe, O
AU  - Knežević, Željka
AU  - O’Connor, U
AU  - Merce, M Sans
AU  - Sarmento, S
AU  - Savary, A
AU  - Siskoonen, T
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9051
AB  - Medical staff in interventional procedures are among the professionals with the highest occupational doses. Active personal dosemeters (APDs) can help in optimizing the exposure during interventional procedures. However, there can be problems when using APDs during interventional procedures, due to the specific energy and angular distribution of the radiation field and because of the pulsed nature of the radiation. Many parameters like the type of interventional procedure, personal habits and working techniques, protection tools used and X-ray field characteristics influence the occupational exposure and the scattered radiation around the patient. In this paper, we compare the results from three types of APDs with a passive personal dosimetry system while being used in real clinical environment by the interventional staff. The results show that there is a large spread in the ratios of the passive and active devices.
T2  - Radiation Protection Dosimetry
T1  - The use of active personal dosemeters in interventional workplaces in hospitals: comparison between active and passive dosemeters worn simultaneously by medical staff
VL  - 188
IS  - 1
SP  - 22
EP  - 29
DO  - 10.1093/rpd/ncz253
ER  - 
@article{
author = "Vanhavere, Filip and Carinou, Eleftheria and Clairand, Isabelle and Ciraj-Bjelac, Olivera and De Monte, F and Domienik-Andrzejewska, J and Ferrari, P and Ginjaume, M and Hršak, Hrvoje and Hupe, O and Knežević, Željka and O’Connor, U and Merce, M Sans and Sarmento, S and Savary, A and Siskoonen, T",
year = "2020",
abstract = "Medical staff in interventional procedures are among the professionals with the highest occupational doses. Active personal dosemeters (APDs) can help in optimizing the exposure during interventional procedures. However, there can be problems when using APDs during interventional procedures, due to the specific energy and angular distribution of the radiation field and because of the pulsed nature of the radiation. Many parameters like the type of interventional procedure, personal habits and working techniques, protection tools used and X-ray field characteristics influence the occupational exposure and the scattered radiation around the patient. In this paper, we compare the results from three types of APDs with a passive personal dosimetry system while being used in real clinical environment by the interventional staff. The results show that there is a large spread in the ratios of the passive and active devices.",
journal = "Radiation Protection Dosimetry",
title = "The use of active personal dosemeters in interventional workplaces in hospitals: comparison between active and passive dosemeters worn simultaneously by medical staff",
volume = "188",
number = "1",
pages = "22-29",
doi = "10.1093/rpd/ncz253"
}
Vanhavere, F., Carinou, E., Clairand, I., Ciraj-Bjelac, O., De Monte, F., Domienik-Andrzejewska, J., Ferrari, P., Ginjaume, M., Hršak, H., Hupe, O., Knežević, Ž., O’Connor, U., Merce, M. S., Sarmento, S., Savary, A.,& Siskoonen, T.. (2020). The use of active personal dosemeters in interventional workplaces in hospitals: comparison between active and passive dosemeters worn simultaneously by medical staff. in Radiation Protection Dosimetry, 188(1), 22-29.
https://doi.org/10.1093/rpd/ncz253
Vanhavere F, Carinou E, Clairand I, Ciraj-Bjelac O, De Monte F, Domienik-Andrzejewska J, Ferrari P, Ginjaume M, Hršak H, Hupe O, Knežević Ž, O’Connor U, Merce MS, Sarmento S, Savary A, Siskoonen T. The use of active personal dosemeters in interventional workplaces in hospitals: comparison between active and passive dosemeters worn simultaneously by medical staff. in Radiation Protection Dosimetry. 2020;188(1):22-29.
doi:10.1093/rpd/ncz253 .
Vanhavere, Filip, Carinou, Eleftheria, Clairand, Isabelle, Ciraj-Bjelac, Olivera, De Monte, F, Domienik-Andrzejewska, J, Ferrari, P, Ginjaume, M, Hršak, Hrvoje, Hupe, O, Knežević, Željka, O’Connor, U, Merce, M Sans, Sarmento, S, Savary, A, Siskoonen, T, "The use of active personal dosemeters in interventional workplaces in hospitals: comparison between active and passive dosemeters worn simultaneously by medical staff" in Radiation Protection Dosimetry, 188, no. 1 (2020):22-29,
https://doi.org/10.1093/rpd/ncz253 . .