Palcevskis, Eriks

Link to this page

Authority KeyName Variants
bc8540a2-e36d-4cf8-a20d-4c67d086d5b8
  • Palcevskis, Eriks (1)
Projects

Author's Bibliography

Corrosion Stability and Bioactivity in Simulated Body Fluid of Silver/Hydroxyapatite and Silver/Hydroxyapatite/Lignin Coatings on Titanium Obtained by Electrophoretic Deposition

Eraković, Sanja; Janković, Ana; Veljović, Đorđe N.; Palcevskis, Eriks; Mitrić, Miodrag; Stevanović, Tatjana; Janaćković, Đorđe T.; Mišković-Stanković, Vesna B.

(2013)

TY  - JOUR
AU  - Eraković, Sanja
AU  - Janković, Ana
AU  - Veljović, Đorđe N.
AU  - Palcevskis, Eriks
AU  - Mitrić, Miodrag
AU  - Stevanović, Tatjana
AU  - Janaćković, Đorđe T.
AU  - Mišković-Stanković, Vesna B.
PY  - 2013
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/5321
AB  - Hydroxyapatite is the most suitable biocompatible material for bone implant coatings. However, its brittleness is a major obstacle, and that is why, recently, research focused on creating composites with various biopolymers. In this study, hydroxyapatite coatings were modified with lignin in order to attain corrosion stability and surface porosity that enables osteogenesis. Incorporating silver, well known for its antimicrobial properties, seemed the best strategy for avoiding possible infections. The silver/hydroxyapatite (Ag/HAP) and silver/hydroxyapatite/lignin (Ag/HAP/Lig) coatings were cathaphoretically deposited on titanium from ethanol suspensions, sintered at 900 degrees C in Ar, and characterized by X-ray diffraction, scanning electron microscopy, field emission scanning electron microscopy, attenuated total reflection Fourier transform infrared, and X-ray photoelectron spectroscopy. The corrosion stability of electrodeposited coatings was evaluated in vitro in Kokubos simulated body fluid (SBF) at 37 degrees C using electrochemical impedance spectroscopy. Bioactivity was estimated by immersion in SBF to evaluate the formation of hydroxyapatite on the coating surface. A microcrystalline structure of newly formed plate-shaped carbonate-hydroxyapatite was detected after only 7 days, indicating enhanced bioactive behavior. Both coatings had good corrosion stability during a prolonged immersion time. Among the two, the Ag/HAP/Lig coating had a homogeneous surface, less roughness, and low values of contact angle.
T2  - Journal of Physical Chemistry. Part B: Condensed Matter, Materials, Surfaces, Interfaces and Biophysical
T1  - Corrosion Stability and Bioactivity in Simulated Body Fluid of Silver/Hydroxyapatite and Silver/Hydroxyapatite/Lignin Coatings on Titanium Obtained by Electrophoretic Deposition
VL  - 117
IS  - 6
SP  - 1633
EP  - 1643
DO  - 10.1021/jp305252a
ER  - 
@article{
author = "Eraković, Sanja and Janković, Ana and Veljović, Đorđe N. and Palcevskis, Eriks and Mitrić, Miodrag and Stevanović, Tatjana and Janaćković, Đorđe T. and Mišković-Stanković, Vesna B.",
year = "2013",
abstract = "Hydroxyapatite is the most suitable biocompatible material for bone implant coatings. However, its brittleness is a major obstacle, and that is why, recently, research focused on creating composites with various biopolymers. In this study, hydroxyapatite coatings were modified with lignin in order to attain corrosion stability and surface porosity that enables osteogenesis. Incorporating silver, well known for its antimicrobial properties, seemed the best strategy for avoiding possible infections. The silver/hydroxyapatite (Ag/HAP) and silver/hydroxyapatite/lignin (Ag/HAP/Lig) coatings were cathaphoretically deposited on titanium from ethanol suspensions, sintered at 900 degrees C in Ar, and characterized by X-ray diffraction, scanning electron microscopy, field emission scanning electron microscopy, attenuated total reflection Fourier transform infrared, and X-ray photoelectron spectroscopy. The corrosion stability of electrodeposited coatings was evaluated in vitro in Kokubos simulated body fluid (SBF) at 37 degrees C using electrochemical impedance spectroscopy. Bioactivity was estimated by immersion in SBF to evaluate the formation of hydroxyapatite on the coating surface. A microcrystalline structure of newly formed plate-shaped carbonate-hydroxyapatite was detected after only 7 days, indicating enhanced bioactive behavior. Both coatings had good corrosion stability during a prolonged immersion time. Among the two, the Ag/HAP/Lig coating had a homogeneous surface, less roughness, and low values of contact angle.",
journal = "Journal of Physical Chemistry. Part B: Condensed Matter, Materials, Surfaces, Interfaces and Biophysical",
title = "Corrosion Stability and Bioactivity in Simulated Body Fluid of Silver/Hydroxyapatite and Silver/Hydroxyapatite/Lignin Coatings on Titanium Obtained by Electrophoretic Deposition",
volume = "117",
number = "6",
pages = "1633-1643",
doi = "10.1021/jp305252a"
}
Eraković, S., Janković, A., Veljović, Đ. N., Palcevskis, E., Mitrić, M., Stevanović, T., Janaćković, Đ. T.,& Mišković-Stanković, V. B.. (2013). Corrosion Stability and Bioactivity in Simulated Body Fluid of Silver/Hydroxyapatite and Silver/Hydroxyapatite/Lignin Coatings on Titanium Obtained by Electrophoretic Deposition. in Journal of Physical Chemistry. Part B: Condensed Matter, Materials, Surfaces, Interfaces and Biophysical, 117(6), 1633-1643.
https://doi.org/10.1021/jp305252a
Eraković S, Janković A, Veljović ĐN, Palcevskis E, Mitrić M, Stevanović T, Janaćković ĐT, Mišković-Stanković VB. Corrosion Stability and Bioactivity in Simulated Body Fluid of Silver/Hydroxyapatite and Silver/Hydroxyapatite/Lignin Coatings on Titanium Obtained by Electrophoretic Deposition. in Journal of Physical Chemistry. Part B: Condensed Matter, Materials, Surfaces, Interfaces and Biophysical. 2013;117(6):1633-1643.
doi:10.1021/jp305252a .
Eraković, Sanja, Janković, Ana, Veljović, Đorđe N., Palcevskis, Eriks, Mitrić, Miodrag, Stevanović, Tatjana, Janaćković, Đorđe T., Mišković-Stanković, Vesna B., "Corrosion Stability and Bioactivity in Simulated Body Fluid of Silver/Hydroxyapatite and Silver/Hydroxyapatite/Lignin Coatings on Titanium Obtained by Electrophoretic Deposition" in Journal of Physical Chemistry. Part B: Condensed Matter, Materials, Surfaces, Interfaces and Biophysical, 117, no. 6 (2013):1633-1643,
https://doi.org/10.1021/jp305252a . .
89
73
95