Anojčić, J.

Link to this page

Authority KeyName Variants
638c17eb-8380-4335-806b-ceab72d806af
  • Anojčić, J. (1)
Projects

Author's Bibliography

Amperometric determination of cholesterol using cholesterol oxidase immobilized on Pt,Ru-C nanocomposite and an ionic liquid-modified carbon paste electrode

Mutić, Sanja; Stanković, Dalibor; Konya, Z.; Anojčić, J.

(University of Belgrade : Faculty of Chemistry, 2023)

TY  - CONF
AU  - Mutić, Sanja
AU  - Stanković, Dalibor
AU  - Konya, Z.
AU  - Anojčić, J.
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11962
AB  - Cholesterol as very important biomolecule is the precursor of many biologically significant compounds which give strength and flexibility to the biological membranes. It is also a crucial component in lipoproteins, and has an important role to transport hydrophobic molecules in hydrophilic media such as blood [1, 2]. The analytical performance of carbon paste electrodes (CPE) bulk modified with ionic liquid 1-allyl-3-methylimidazolium dicyanamide ([AMIM][DCA]), and surface modified with platinum on graphitized carbon (Pt-C) or platinum-ruthenium alloy on graphitized carbon (Pt,Ru-C) for analysis of hydrogen peroxide (H 2O2) were compared. The prepared working electrodes were characterized using scanning electron microscopy–energydispersive X-ray spectrometry, together with electrochemical impedance spectroscopic, cyclic voltammetric, and amperometric techniques. After method optimization, an enzyme cholesterol oxidase (ChOx) was immobilized on the surface of Pt,Ru-C/IL-CPE by Nafion®. The improved cholesterol amperometric determination was achieved in phosphate buffer solution pH 7.50 at a working potential of 0.60 V. Under the optimized experimental conditions, a linear relationship between oxidation current and cholesterol concentration was in the concentration range from 0.31 to 2.46 µM, with an estimated detection limit of 0.13 µM and relative standard deviation (RSD) below 4.2%. The optimized amperometric method in combination with the developed ChOx/Pt,Ru-C/IL-CPE biosensor showed good repeatability and high selectivity towards cholesterol biosensing despite the presence of possible interferences. The ChOx/Pt,Ru-C/IL-CPE was tested for the determination of the free cholesterol, by its enzymatic reaction product H 2O2, in a human blood serum sample. The percentage recovery ranged from 99.08 to 102.81%, while RSD was below 2.0% for untreated, as well as for spiked human blood serum sample.
PB  - University of Belgrade : Faculty of Chemistry
C3  - YISAC 2023 : 28th Young Investigators' Seminar on Analytical Chemistry : the book of abstracts
T1  - Amperometric determination of cholesterol using cholesterol oxidase immobilized on Pt,Ru-C nanocomposite and an ionic liquid-modified carbon paste electrode
SP  - 53
EP  - 53
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11962
ER  - 
@conference{
author = "Mutić, Sanja and Stanković, Dalibor and Konya, Z. and Anojčić, J.",
year = "2023",
abstract = "Cholesterol as very important biomolecule is the precursor of many biologically significant compounds which give strength and flexibility to the biological membranes. It is also a crucial component in lipoproteins, and has an important role to transport hydrophobic molecules in hydrophilic media such as blood [1, 2]. The analytical performance of carbon paste electrodes (CPE) bulk modified with ionic liquid 1-allyl-3-methylimidazolium dicyanamide ([AMIM][DCA]), and surface modified with platinum on graphitized carbon (Pt-C) or platinum-ruthenium alloy on graphitized carbon (Pt,Ru-C) for analysis of hydrogen peroxide (H 2O2) were compared. The prepared working electrodes were characterized using scanning electron microscopy–energydispersive X-ray spectrometry, together with electrochemical impedance spectroscopic, cyclic voltammetric, and amperometric techniques. After method optimization, an enzyme cholesterol oxidase (ChOx) was immobilized on the surface of Pt,Ru-C/IL-CPE by Nafion®. The improved cholesterol amperometric determination was achieved in phosphate buffer solution pH 7.50 at a working potential of 0.60 V. Under the optimized experimental conditions, a linear relationship between oxidation current and cholesterol concentration was in the concentration range from 0.31 to 2.46 µM, with an estimated detection limit of 0.13 µM and relative standard deviation (RSD) below 4.2%. The optimized amperometric method in combination with the developed ChOx/Pt,Ru-C/IL-CPE biosensor showed good repeatability and high selectivity towards cholesterol biosensing despite the presence of possible interferences. The ChOx/Pt,Ru-C/IL-CPE was tested for the determination of the free cholesterol, by its enzymatic reaction product H 2O2, in a human blood serum sample. The percentage recovery ranged from 99.08 to 102.81%, while RSD was below 2.0% for untreated, as well as for spiked human blood serum sample.",
publisher = "University of Belgrade : Faculty of Chemistry",
journal = "YISAC 2023 : 28th Young Investigators' Seminar on Analytical Chemistry : the book of abstracts",
title = "Amperometric determination of cholesterol using cholesterol oxidase immobilized on Pt,Ru-C nanocomposite and an ionic liquid-modified carbon paste electrode",
pages = "53-53",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11962"
}
Mutić, S., Stanković, D., Konya, Z.,& Anojčić, J.. (2023). Amperometric determination of cholesterol using cholesterol oxidase immobilized on Pt,Ru-C nanocomposite and an ionic liquid-modified carbon paste electrode. in YISAC 2023 : 28th Young Investigators' Seminar on Analytical Chemistry : the book of abstracts
University of Belgrade : Faculty of Chemistry., 53-53.
https://hdl.handle.net/21.15107/rcub_vinar_11962
Mutić S, Stanković D, Konya Z, Anojčić J. Amperometric determination of cholesterol using cholesterol oxidase immobilized on Pt,Ru-C nanocomposite and an ionic liquid-modified carbon paste electrode. in YISAC 2023 : 28th Young Investigators' Seminar on Analytical Chemistry : the book of abstracts. 2023;:53-53.
https://hdl.handle.net/21.15107/rcub_vinar_11962 .
Mutić, Sanja, Stanković, Dalibor, Konya, Z., Anojčić, J., "Amperometric determination of cholesterol using cholesterol oxidase immobilized on Pt,Ru-C nanocomposite and an ionic liquid-modified carbon paste electrode" in YISAC 2023 : 28th Young Investigators' Seminar on Analytical Chemistry : the book of abstracts (2023):53-53,
https://hdl.handle.net/21.15107/rcub_vinar_11962 .