Kodlulovich Renha, S.

Link to this page

Authority KeyName Variants
b8479b46-0601-4a83-b88d-2d7370776594
  • Kodlulovich Renha, S. (1)
Projects
No records found.

Author's Bibliography

A Study to Establish International Diagnostic Reference Levels for Paediatric Computed Tomography

Vassileva, J.; Rehani, M.; Kostova-Lefterova, D.; Al-Naemi, H. M.; Al Suwaidi, J. S.; Aranđić, Danijela; Bashier, E. H. O.; Kodlulovich Renha, S.; El-Nachef, L.; Aguilar, J. G.; Gershan, Vesna; Gershkevitsh, E.; Gruppetta, E.; Hustuc, A.; Jauhari, A.; Kharita, Mohammad Hassan; Khelassi-Toutaoui, N.; Khosravi, H. R.; Khoury, H.; Kralik, I.; Mahere, S.; Mazuoliene, J.; Mora, P.; Muhogora, W.; Muthuvelu, P.; Nikodemova, D.; Novak, L.; Pallewatte, A.; Pekarovic, D.; Shaaban, M.; Shelly, E.; Stepanyan, K.; Thelsy, N.; Visrutaratna, P.; Zaman, A.

(2015)

TY  - JOUR
AU  - Vassileva, J.
AU  - Rehani, M.
AU  - Kostova-Lefterova, D.
AU  - Al-Naemi, H. M.
AU  - Al Suwaidi, J. S.
AU  - Aranđić, Danijela
AU  - Bashier, E. H. O.
AU  - Kodlulovich Renha, S.
AU  - El-Nachef, L.
AU  - Aguilar, J. G.
AU  - Gershan, Vesna
AU  - Gershkevitsh, E.
AU  - Gruppetta, E.
AU  - Hustuc, A.
AU  - Jauhari, A.
AU  - Kharita, Mohammad Hassan
AU  - Khelassi-Toutaoui, N.
AU  - Khosravi, H. R.
AU  - Khoury, H.
AU  - Kralik, I.
AU  - Mahere, S.
AU  - Mazuoliene, J.
AU  - Mora, P.
AU  - Muhogora, W.
AU  - Muthuvelu, P.
AU  - Nikodemova, D.
AU  - Novak, L.
AU  - Pallewatte, A.
AU  - Pekarovic, D.
AU  - Shaaban, M.
AU  - Shelly, E.
AU  - Stepanyan, K.
AU  - Thelsy, N.
AU  - Visrutaratna, P.
AU  - Zaman, A.
PY  - 2015
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/668
AB  - The article reports from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index (CTDIvol) and dose length product (DLP). It also assesses whether mean or median values of individual facilities should be used. A total of 6115 individual patient data were recorded among four age groups: LT 1 y, GT 1-5 y, GT 5-10 y and GT 10-15 y. CTDIw, CTDIvol and DLP from the CT console were recorded in dedicated forms together with patient data and technical parameters. Statistical analysis was performed, and international DRLs were established at rounded 75th percentile values of distribution of median values from all CT facilities. The study presents evidence in favour of using median rather than mean of patient dose indices as the representative of typical local dose in a facility, and for establishing DRLs as third quartile of median values. International DRLs were established for paediatric CT examinations for routine head, chest and abdomen in the four age groups. DRLs for CTDIvol are similar to the reference values from other published reports, with some differences for chest and abdomen CT. Higher variations were observed between DLP values, based on a survey of whole multi-phase exams. It may be noted that other studies in literature were based on single phase only. DRLs reported in this article can be used in countries without sufficient medical physics support to identify non-optimised practice. Recommendations to improve the accuracy and importance of future surveys are provided.
T2  - Radiation Protection Dosimetry
T1  - A Study to Establish International Diagnostic Reference Levels for Paediatric Computed Tomography
VL  - 165
IS  - 1-4
SP  - 70
EP  - 80
DO  - 10.1093/rpd/ncv116
ER  - 
@article{
author = "Vassileva, J. and Rehani, M. and Kostova-Lefterova, D. and Al-Naemi, H. M. and Al Suwaidi, J. S. and Aranđić, Danijela and Bashier, E. H. O. and Kodlulovich Renha, S. and El-Nachef, L. and Aguilar, J. G. and Gershan, Vesna and Gershkevitsh, E. and Gruppetta, E. and Hustuc, A. and Jauhari, A. and Kharita, Mohammad Hassan and Khelassi-Toutaoui, N. and Khosravi, H. R. and Khoury, H. and Kralik, I. and Mahere, S. and Mazuoliene, J. and Mora, P. and Muhogora, W. and Muthuvelu, P. and Nikodemova, D. and Novak, L. and Pallewatte, A. and Pekarovic, D. and Shaaban, M. and Shelly, E. and Stepanyan, K. and Thelsy, N. and Visrutaratna, P. and Zaman, A.",
year = "2015",
abstract = "The article reports from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index (CTDIvol) and dose length product (DLP). It also assesses whether mean or median values of individual facilities should be used. A total of 6115 individual patient data were recorded among four age groups: LT 1 y, GT 1-5 y, GT 5-10 y and GT 10-15 y. CTDIw, CTDIvol and DLP from the CT console were recorded in dedicated forms together with patient data and technical parameters. Statistical analysis was performed, and international DRLs were established at rounded 75th percentile values of distribution of median values from all CT facilities. The study presents evidence in favour of using median rather than mean of patient dose indices as the representative of typical local dose in a facility, and for establishing DRLs as third quartile of median values. International DRLs were established for paediatric CT examinations for routine head, chest and abdomen in the four age groups. DRLs for CTDIvol are similar to the reference values from other published reports, with some differences for chest and abdomen CT. Higher variations were observed between DLP values, based on a survey of whole multi-phase exams. It may be noted that other studies in literature were based on single phase only. DRLs reported in this article can be used in countries without sufficient medical physics support to identify non-optimised practice. Recommendations to improve the accuracy and importance of future surveys are provided.",
journal = "Radiation Protection Dosimetry",
title = "A Study to Establish International Diagnostic Reference Levels for Paediatric Computed Tomography",
volume = "165",
number = "1-4",
pages = "70-80",
doi = "10.1093/rpd/ncv116"
}
Vassileva, J., Rehani, M., Kostova-Lefterova, D., Al-Naemi, H. M., Al Suwaidi, J. S., Aranđić, D., Bashier, E. H. O., Kodlulovich Renha, S., El-Nachef, L., Aguilar, J. G., Gershan, V., Gershkevitsh, E., Gruppetta, E., Hustuc, A., Jauhari, A., Kharita, M. H., Khelassi-Toutaoui, N., Khosravi, H. R., Khoury, H., Kralik, I., Mahere, S., Mazuoliene, J., Mora, P., Muhogora, W., Muthuvelu, P., Nikodemova, D., Novak, L., Pallewatte, A., Pekarovic, D., Shaaban, M., Shelly, E., Stepanyan, K., Thelsy, N., Visrutaratna, P.,& Zaman, A.. (2015). A Study to Establish International Diagnostic Reference Levels for Paediatric Computed Tomography. in Radiation Protection Dosimetry, 165(1-4), 70-80.
https://doi.org/10.1093/rpd/ncv116
Vassileva J, Rehani M, Kostova-Lefterova D, Al-Naemi HM, Al Suwaidi JS, Aranđić D, Bashier EHO, Kodlulovich Renha S, El-Nachef L, Aguilar JG, Gershan V, Gershkevitsh E, Gruppetta E, Hustuc A, Jauhari A, Kharita MH, Khelassi-Toutaoui N, Khosravi HR, Khoury H, Kralik I, Mahere S, Mazuoliene J, Mora P, Muhogora W, Muthuvelu P, Nikodemova D, Novak L, Pallewatte A, Pekarovic D, Shaaban M, Shelly E, Stepanyan K, Thelsy N, Visrutaratna P, Zaman A. A Study to Establish International Diagnostic Reference Levels for Paediatric Computed Tomography. in Radiation Protection Dosimetry. 2015;165(1-4):70-80.
doi:10.1093/rpd/ncv116 .
Vassileva, J., Rehani, M., Kostova-Lefterova, D., Al-Naemi, H. M., Al Suwaidi, J. S., Aranđić, Danijela, Bashier, E. H. O., Kodlulovich Renha, S., El-Nachef, L., Aguilar, J. G., Gershan, Vesna, Gershkevitsh, E., Gruppetta, E., Hustuc, A., Jauhari, A., Kharita, Mohammad Hassan, Khelassi-Toutaoui, N., Khosravi, H. R., Khoury, H., Kralik, I., Mahere, S., Mazuoliene, J., Mora, P., Muhogora, W., Muthuvelu, P., Nikodemova, D., Novak, L., Pallewatte, A., Pekarovic, D., Shaaban, M., Shelly, E., Stepanyan, K., Thelsy, N., Visrutaratna, P., Zaman, A., "A Study to Establish International Diagnostic Reference Levels for Paediatric Computed Tomography" in Radiation Protection Dosimetry, 165, no. 1-4 (2015):70-80,
https://doi.org/10.1093/rpd/ncv116 . .
50
33
48