Lazovic, B.

Link to this page

Authority KeyName Variants
48e99669-b047-4f93-a463-bf31942ee47f
  • Lazovic, B. (1)
Projects
No records found.

Author's Bibliography

Rib-Cage-Movement Measurements as a Potential New Trigger Signal in Non-Invasive Mechanical Ventilation

Ivanović, Marija D.; Petrović, Jovana S.; Miletić, Marjan; Daničić, Aleksandar; Bojović, Boško; Vukcevic, M.; Lazovic, B.; Gluvić, Zoran; Hadžievski, Ljupčo; Allsop, Thomas P.; Webb, David J.

(2015)

TY  - CONF
AU  - Ivanović, Marija D.
AU  - Petrović, Jovana S.
AU  - Miletić, Marjan
AU  - Daničić, Aleksandar
AU  - Bojović, Boško
AU  - Vukcevic, M.
AU  - Lazovic, B.
AU  - Gluvić, Zoran
AU  - Hadžievski, Ljupčo
AU  - Allsop, Thomas P.
AU  - Webb, David J.
PY  - 2015
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7097
AB  - Non-invasive ventilation performed through an oronasal mask is a standard in clinical and homecare mechanical ventilation. Besides all its advantages, inevitable leaks through the mask cause errors in the feedback information provided by the airflow sensor and, hence, patient-ventilator asynchrony with multiple negative consequences. Here we investigate a new way to provide a trigger to the ventilator. The method is based on the measurement of rib cage movement at the onset of inspiration and during breathing by fibre-optic sensors. In a series of simultaneous measurements by a long-period fibre grating sensor and pneumotachograph we provide the statistical evidence of the 200 ms lag of the pneumo with respect the fibre-optic signal. The lag is registered consistently across three independent delay metrics. Further, we discuss exceptions from this trend and identify the needed improvements to the proposed fibre-sensing scheme.
T1  - Rib-Cage-Movement Measurements as a Potential New Trigger Signal in Non-Invasive Mechanical Ventilation
SP  - 4511
EP  - 4514
UR  - https://hdl.handle.net/21.15107/rcub_vinar_7097
ER  - 
@conference{
author = "Ivanović, Marija D. and Petrović, Jovana S. and Miletić, Marjan and Daničić, Aleksandar and Bojović, Boško and Vukcevic, M. and Lazovic, B. and Gluvić, Zoran and Hadžievski, Ljupčo and Allsop, Thomas P. and Webb, David J.",
year = "2015",
abstract = "Non-invasive ventilation performed through an oronasal mask is a standard in clinical and homecare mechanical ventilation. Besides all its advantages, inevitable leaks through the mask cause errors in the feedback information provided by the airflow sensor and, hence, patient-ventilator asynchrony with multiple negative consequences. Here we investigate a new way to provide a trigger to the ventilator. The method is based on the measurement of rib cage movement at the onset of inspiration and during breathing by fibre-optic sensors. In a series of simultaneous measurements by a long-period fibre grating sensor and pneumotachograph we provide the statistical evidence of the 200 ms lag of the pneumo with respect the fibre-optic signal. The lag is registered consistently across three independent delay metrics. Further, we discuss exceptions from this trend and identify the needed improvements to the proposed fibre-sensing scheme.",
title = "Rib-Cage-Movement Measurements as a Potential New Trigger Signal in Non-Invasive Mechanical Ventilation",
pages = "4511-4514",
url = "https://hdl.handle.net/21.15107/rcub_vinar_7097"
}
Ivanović, M. D., Petrović, J. S., Miletić, M., Daničić, A., Bojović, B., Vukcevic, M., Lazovic, B., Gluvić, Z., Hadžievski, L., Allsop, T. P.,& Webb, D. J.. (2015). Rib-Cage-Movement Measurements as a Potential New Trigger Signal in Non-Invasive Mechanical Ventilation. , 4511-4514.
https://hdl.handle.net/21.15107/rcub_vinar_7097
Ivanović MD, Petrović JS, Miletić M, Daničić A, Bojović B, Vukcevic M, Lazovic B, Gluvić Z, Hadžievski L, Allsop TP, Webb DJ. Rib-Cage-Movement Measurements as a Potential New Trigger Signal in Non-Invasive Mechanical Ventilation. 2015;:4511-4514.
https://hdl.handle.net/21.15107/rcub_vinar_7097 .
Ivanović, Marija D., Petrović, Jovana S., Miletić, Marjan, Daničić, Aleksandar, Bojović, Boško, Vukcevic, M., Lazovic, B., Gluvić, Zoran, Hadžievski, Ljupčo, Allsop, Thomas P., Webb, David J., "Rib-Cage-Movement Measurements as a Potential New Trigger Signal in Non-Invasive Mechanical Ventilation" (2015):4511-4514,
https://hdl.handle.net/21.15107/rcub_vinar_7097 .
2