Iurlaro, Giorgia

Link to this page

Authority KeyName Variants
aadb022d-4326-4694-80a9-ef383d2b6aff
  • Iurlaro, Giorgia (5)
Projects

Author's Bibliography

Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event

Knežević, Željka; Majer, Marija; Baranowska, Zuzanna; Ciraj-Bjelac, Olivera; Iurlaro, Giorgia; Krzanović, Nikola; Mariotti, Francesca; Nodilo, Marijana; Neumaier, Stefan; Woloszczuk, Katarzyna; Živanović, Miloš Z.

(2021)

TY  - JOUR
AU  - Knežević, Željka
AU  - Majer, Marija
AU  - Baranowska, Zuzanna
AU  - Ciraj-Bjelac, Olivera
AU  - Iurlaro, Giorgia
AU  - Krzanović, Nikola
AU  - Mariotti, Francesca
AU  - Nodilo, Marijana
AU  - Neumaier, Stefan
AU  - Woloszczuk, Katarzyna
AU  - Živanović, Miloš Z.
PY  - 2021
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9934
AB  - Due to the need for harmonization of passive dosimetry and the requirements of the international standards in the area of environmental monitoring in radiation protection, multiple types of various passive dosimetry systems based on different ionizing radiation detection mechanisms were subjected to extensive performance testing. In the scope of the EMPIR project 16ENV04 Preparedness, the performance of 12 passive dosimetry systems was examined in radiation fields of different photon energies, angles of incidence and ambient dose equivalent rates in order to estimate their performance in the almost omni-directionally and energetically broad radiation field of the natural environment. The use of different detectors, holders, calibrations, measurement procedures and uncertainties, leads to differences in the measured data. Prior investigations and harmonization of passive dosimetry systems are necessary to achieve reliable and comparable dose measurements in Europe.
T2  - Radiation Measurements
T1  - Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event
VL  - 146
SP  - 106615
DO  - 10.1016/j.radmeas.2021.106615
ER  - 
@article{
author = "Knežević, Željka and Majer, Marija and Baranowska, Zuzanna and Ciraj-Bjelac, Olivera and Iurlaro, Giorgia and Krzanović, Nikola and Mariotti, Francesca and Nodilo, Marijana and Neumaier, Stefan and Woloszczuk, Katarzyna and Živanović, Miloš Z.",
year = "2021",
abstract = "Due to the need for harmonization of passive dosimetry and the requirements of the international standards in the area of environmental monitoring in radiation protection, multiple types of various passive dosimetry systems based on different ionizing radiation detection mechanisms were subjected to extensive performance testing. In the scope of the EMPIR project 16ENV04 Preparedness, the performance of 12 passive dosimetry systems was examined in radiation fields of different photon energies, angles of incidence and ambient dose equivalent rates in order to estimate their performance in the almost omni-directionally and energetically broad radiation field of the natural environment. The use of different detectors, holders, calibrations, measurement procedures and uncertainties, leads to differences in the measured data. Prior investigations and harmonization of passive dosimetry systems are necessary to achieve reliable and comparable dose measurements in Europe.",
journal = "Radiation Measurements",
title = "Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event",
volume = "146",
pages = "106615",
doi = "10.1016/j.radmeas.2021.106615"
}
Knežević, Ž., Majer, M., Baranowska, Z., Ciraj-Bjelac, O., Iurlaro, G., Krzanović, N., Mariotti, F., Nodilo, M., Neumaier, S., Woloszczuk, K.,& Živanović, M. Z.. (2021). Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event. in Radiation Measurements, 146, 106615.
https://doi.org/10.1016/j.radmeas.2021.106615
Knežević Ž, Majer M, Baranowska Z, Ciraj-Bjelac O, Iurlaro G, Krzanović N, Mariotti F, Nodilo M, Neumaier S, Woloszczuk K, Živanović MZ. Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event. in Radiation Measurements. 2021;146:106615.
doi:10.1016/j.radmeas.2021.106615 .
Knežević, Željka, Majer, Marija, Baranowska, Zuzanna, Ciraj-Bjelac, Olivera, Iurlaro, Giorgia, Krzanović, Nikola, Mariotti, Francesca, Nodilo, Marijana, Neumaier, Stefan, Woloszczuk, Katarzyna, Živanović, Miloš Z., "Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event" in Radiation Measurements, 146 (2021):106615,
https://doi.org/10.1016/j.radmeas.2021.106615 . .
6
1
7

Testing of low-cost dosimeters used in non-governmental networks within 16ENV04 Preparedness project

Živanović, Miloš; Morosh, Viacheslav; Kržanović, Nikola; Iurlaro, Giorgia; Bell, Steven; Sangiorgi, Marco; Pantelić, Gordana K.; Ciraj-Bjelac, Olivera; Đaletić, Miloš; Sperandio, Luciano; Ioannidis, Sotiris

(RAD Centre, Niš, Serbia, 2020)

TY  - CONF
AU  - Živanović, Miloš
AU  - Morosh, Viacheslav
AU  - Kržanović, Nikola
AU  - Iurlaro, Giorgia
AU  - Bell, Steven
AU  - Sangiorgi, Marco
AU  - Pantelić, Gordana K.
AU  - Ciraj-Bjelac, Olivera
AU  - Đaletić, Miloš
AU  - Sperandio, Luciano
AU  - Ioannidis, Sotiris
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11138
PB  - RAD Centre, Niš, Serbia
C3  - RAD 2020 : 8th International Conference on Radiation in Various Fields of Research : book of abstracts; Virtual Conference
T1  - Testing of low-cost dosimeters used in non-governmental networks within 16ENV04 Preparedness project
SP  - 93
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11138
ER  - 
@conference{
author = "Živanović, Miloš and Morosh, Viacheslav and Kržanović, Nikola and Iurlaro, Giorgia and Bell, Steven and Sangiorgi, Marco and Pantelić, Gordana K. and Ciraj-Bjelac, Olivera and Đaletić, Miloš and Sperandio, Luciano and Ioannidis, Sotiris",
year = "2020",
publisher = "RAD Centre, Niš, Serbia",
journal = "RAD 2020 : 8th International Conference on Radiation in Various Fields of Research : book of abstracts; Virtual Conference",
title = "Testing of low-cost dosimeters used in non-governmental networks within 16ENV04 Preparedness project",
pages = "93",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11138"
}
Živanović, M., Morosh, V., Kržanović, N., Iurlaro, G., Bell, S., Sangiorgi, M., Pantelić, G. K., Ciraj-Bjelac, O., Đaletić, M., Sperandio, L.,& Ioannidis, S.. (2020). Testing of low-cost dosimeters used in non-governmental networks within 16ENV04 Preparedness project. in RAD 2020 : 8th International Conference on Radiation in Various Fields of Research : book of abstracts; Virtual Conference
RAD Centre, Niš, Serbia., 93.
https://hdl.handle.net/21.15107/rcub_vinar_11138
Živanović M, Morosh V, Kržanović N, Iurlaro G, Bell S, Sangiorgi M, Pantelić GK, Ciraj-Bjelac O, Đaletić M, Sperandio L, Ioannidis S. Testing of low-cost dosimeters used in non-governmental networks within 16ENV04 Preparedness project. in RAD 2020 : 8th International Conference on Radiation in Various Fields of Research : book of abstracts; Virtual Conference. 2020;:93.
https://hdl.handle.net/21.15107/rcub_vinar_11138 .
Živanović, Miloš, Morosh, Viacheslav, Kržanović, Nikola, Iurlaro, Giorgia, Bell, Steven, Sangiorgi, Marco, Pantelić, Gordana K., Ciraj-Bjelac, Olivera, Đaletić, Miloš, Sperandio, Luciano, Ioannidis, Sotiris, "Testing of low-cost dosimeters used in non-governmental networks within 16ENV04 Preparedness project" in RAD 2020 : 8th International Conference on Radiation in Various Fields of Research : book of abstracts; Virtual Conference (2020):93,
https://hdl.handle.net/21.15107/rcub_vinar_11138 .

Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation

Kržanović, Nikola; Živanović, Miloš; Morosh, Viacheslav; Neumaier, Stefan; Röttger, Annette; Iurlaro, Giorgia; Bell, Stevan; Sangiorgi, Marco; Ciraj-Bjelac, Olivera; Pantelić, Gordana; Đaletić, Miloš; Sperandio, Luciano; Ioannidis, Sotiris

(Niš : Sievert Association, 2020)

TY  - CONF
AU  - Kržanović, Nikola
AU  - Živanović, Miloš
AU  - Morosh, Viacheslav
AU  - Neumaier, Stefan
AU  - Röttger, Annette
AU  - Iurlaro, Giorgia
AU  - Bell, Stevan
AU  - Sangiorgi, Marco
AU  - Ciraj-Bjelac, Olivera
AU  - Pantelić, Gordana
AU  - Đaletić, Miloš
AU  - Sperandio, Luciano
AU  - Ioannidis, Sotiris
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11905
AB  - Non-governmental networks for environmental monitoring employ a wide range of radiation protection instruments from different manufacturers, which provide the public with often unreliable dosimetric data. These Measuring Instruments in Non-governmental Networks (MINN) are mostly based on Geiger-Muller tube gas detectors, which represent low-cost easily operated instruments. An extensive testing of these devices was performed in order to validate the data acquired with MINN within the 16ENV04 Preparedness EMPIR project. In total, 16 different dosemter types were selected, with a sample size of four dosemeters per dosemeter type. Performance testing included the energy dependence and the linearity tests of the dosemeter response. Additionally, during the Researcher Mobility Grant associated with the 16ENV04 project, two Geiger-Muller based dosemeter types, with a sample size of two dosemeters per type were included in the testing. These instruments were subjected to the angular dependence testing in both horizontal and vertical planes, besides the energy dependence and linearity tests in the reference Cs-137 field at Physikalisch-Technische Bundesanstalt (PTB). For all the dosemeter types, inherent background, response to secondary cosmic radiation and the response to small changes of dose rate were determined at the metrological facilities of PTB. The sensitivity of the measuring instruments used in non-governmental networks to small variations of the ambient dose equivalent rate was examined by exposing the dosemeters to low dose rate Cs-137, Co-60 and Ra-226 radiation sources, in order to estimate the effect of environmental radioactive contamination with artificially produced radionuclides. For the comparison purposes, besides the measuring instruments used in non-governmental networks, a previously characterized CdZnTe-based spectrodosemeter was irradiated with the aforementioned radiation fields. The measured values were compared with a reference Reuter-Stokes ionisation chamber used for low-dose rate level measurements.
PB  - Niš : Sievert Association
C3  - RAP 2020 : International conference on radiation applications; Book of abstracts
T1  - Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation
SP  - 11
EP  - 11
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11905
ER  - 
@conference{
author = "Kržanović, Nikola and Živanović, Miloš and Morosh, Viacheslav and Neumaier, Stefan and Röttger, Annette and Iurlaro, Giorgia and Bell, Stevan and Sangiorgi, Marco and Ciraj-Bjelac, Olivera and Pantelić, Gordana and Đaletić, Miloš and Sperandio, Luciano and Ioannidis, Sotiris",
year = "2020",
abstract = "Non-governmental networks for environmental monitoring employ a wide range of radiation protection instruments from different manufacturers, which provide the public with often unreliable dosimetric data. These Measuring Instruments in Non-governmental Networks (MINN) are mostly based on Geiger-Muller tube gas detectors, which represent low-cost easily operated instruments. An extensive testing of these devices was performed in order to validate the data acquired with MINN within the 16ENV04 Preparedness EMPIR project. In total, 16 different dosemter types were selected, with a sample size of four dosemeters per dosemeter type. Performance testing included the energy dependence and the linearity tests of the dosemeter response. Additionally, during the Researcher Mobility Grant associated with the 16ENV04 project, two Geiger-Muller based dosemeter types, with a sample size of two dosemeters per type were included in the testing. These instruments were subjected to the angular dependence testing in both horizontal and vertical planes, besides the energy dependence and linearity tests in the reference Cs-137 field at Physikalisch-Technische Bundesanstalt (PTB). For all the dosemeter types, inherent background, response to secondary cosmic radiation and the response to small changes of dose rate were determined at the metrological facilities of PTB. The sensitivity of the measuring instruments used in non-governmental networks to small variations of the ambient dose equivalent rate was examined by exposing the dosemeters to low dose rate Cs-137, Co-60 and Ra-226 radiation sources, in order to estimate the effect of environmental radioactive contamination with artificially produced radionuclides. For the comparison purposes, besides the measuring instruments used in non-governmental networks, a previously characterized CdZnTe-based spectrodosemeter was irradiated with the aforementioned radiation fields. The measured values were compared with a reference Reuter-Stokes ionisation chamber used for low-dose rate level measurements.",
publisher = "Niš : Sievert Association",
journal = "RAP 2020 : International conference on radiation applications; Book of abstracts",
title = "Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation",
pages = "11-11",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11905"
}
Kržanović, N., Živanović, M., Morosh, V., Neumaier, S., Röttger, A., Iurlaro, G., Bell, S., Sangiorgi, M., Ciraj-Bjelac, O., Pantelić, G., Đaletić, M., Sperandio, L.,& Ioannidis, S.. (2020). Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation. in RAP 2020 : International conference on radiation applications; Book of abstracts
Niš : Sievert Association., 11-11.
https://hdl.handle.net/21.15107/rcub_vinar_11905
Kržanović N, Živanović M, Morosh V, Neumaier S, Röttger A, Iurlaro G, Bell S, Sangiorgi M, Ciraj-Bjelac O, Pantelić G, Đaletić M, Sperandio L, Ioannidis S. Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation. in RAP 2020 : International conference on radiation applications; Book of abstracts. 2020;:11-11.
https://hdl.handle.net/21.15107/rcub_vinar_11905 .
Kržanović, Nikola, Živanović, Miloš, Morosh, Viacheslav, Neumaier, Stefan, Röttger, Annette, Iurlaro, Giorgia, Bell, Stevan, Sangiorgi, Marco, Ciraj-Bjelac, Olivera, Pantelić, Gordana, Đaletić, Miloš, Sperandio, Luciano, Ioannidis, Sotiris, "Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation" in RAP 2020 : International conference on radiation applications; Book of abstracts (2020):11-11,
https://hdl.handle.net/21.15107/rcub_vinar_11905 .

Ispitivanje valjanosti podataka o jačini doze dobijenih iz civilnih mreža

Živanović, Miloš Z.; Kržanović, Nikola; Iurlaro, Giorgia; Bell, Steven; Morosh, Viacheslav; Đaletić, Miloš; Pantelić, Gordana K.

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2019)

TY  - CONF
AU  - Živanović, Miloš Z.
AU  - Kržanović, Nikola
AU  - Iurlaro, Giorgia
AU  - Bell, Steven
AU  - Morosh, Viacheslav
AU  - Đaletić, Miloš
AU  - Pantelić, Gordana K.
PY  - 2019
UR  - https://plus.sr.cobiss.net/opac7/bib/279687436
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8703
AB  - Broj civilnih mreža koje pružaju kvazi-trenutne podatke o jačini doze je poslednjih godina u porastu. Ovi podaci su javno dostupni preko internet platfomi sa slobodnim pristupom. Istraživanja na temu civilnih mreža su retka, a merenja čiji su rezultati u njima predstavljeni su uglavnom izvršena široko dostupnim jednostavnim ručnim dozimetrima. Bez detaljnog testiranja ovih uređaja u metrološkim laboratorijama, postoji velika verovatnoša javljanja značajnih razlika između zvaničnih podataka i podataka iz civilnih mreža, što može imati značajne posledice. U okviru projekta 16ENV04 Preparedness je sprovedeno sistematskoispitivanje civilnih mreža. Tako je identifikovano 16 tipova uređaja koji se često koriste. Učesnici projekta su nabavili po 4 dozimetra od svakog tipa, čije je ispitivanje trenutno u toku. Procedura koriššena za ispitivanje je ukratko opisana u ovom radui prikazani su preliminarni rezultati za 2 tipa dozimetara.
AB  - In recent years, the number of non-governmental networks providing quasi real time dose rates is growing. This data is available to the general public via open access based platforms on the internet. The research on the non-governmental networks is scarce and the measurements represented there are mostly carried out using broadly available commercial simple hand-held devices. Without proper testing of these devices in metrological laboratories, there is a significant possibility for discrepancies between the official and non-governmental data, which may have wider implications. Within project 16ENV04 Preparedness, a systematic study of non-governmental networks produced a list of 16 types of dosimeters that are commonly used. Four dosimeters of each type were sourced and commissioned by project partners and are currently undergoing the testing. Test procedures are shortly described in this paper and preliminary results for 2 types of dosimeters are presented.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 30. симпозијум ДЗЗСЦГ : зборник радова
T1  - Ispitivanje valjanosti podataka o jačini doze dobijenih iz civilnih mreža
T1  - Evaluation of dose rate data provided by non-governmental networks
SP  - 297
EP  - 303
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8703
ER  - 
@conference{
author = "Živanović, Miloš Z. and Kržanović, Nikola and Iurlaro, Giorgia and Bell, Steven and Morosh, Viacheslav and Đaletić, Miloš and Pantelić, Gordana K.",
year = "2019",
abstract = "Broj civilnih mreža koje pružaju kvazi-trenutne podatke o jačini doze je poslednjih godina u porastu. Ovi podaci su javno dostupni preko internet platfomi sa slobodnim pristupom. Istraživanja na temu civilnih mreža su retka, a merenja čiji su rezultati u njima predstavljeni su uglavnom izvršena široko dostupnim jednostavnim ručnim dozimetrima. Bez detaljnog testiranja ovih uređaja u metrološkim laboratorijama, postoji velika verovatnoša javljanja značajnih razlika između zvaničnih podataka i podataka iz civilnih mreža, što može imati značajne posledice. U okviru projekta 16ENV04 Preparedness je sprovedeno sistematskoispitivanje civilnih mreža. Tako je identifikovano 16 tipova uređaja koji se često koriste. Učesnici projekta su nabavili po 4 dozimetra od svakog tipa, čije je ispitivanje trenutno u toku. Procedura koriššena za ispitivanje je ukratko opisana u ovom radui prikazani su preliminarni rezultati za 2 tipa dozimetara., In recent years, the number of non-governmental networks providing quasi real time dose rates is growing. This data is available to the general public via open access based platforms on the internet. The research on the non-governmental networks is scarce and the measurements represented there are mostly carried out using broadly available commercial simple hand-held devices. Without proper testing of these devices in metrological laboratories, there is a significant possibility for discrepancies between the official and non-governmental data, which may have wider implications. Within project 16ENV04 Preparedness, a systematic study of non-governmental networks produced a list of 16 types of dosimeters that are commonly used. Four dosimeters of each type were sourced and commissioned by project partners and are currently undergoing the testing. Test procedures are shortly described in this paper and preliminary results for 2 types of dosimeters are presented.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "30. симпозијум ДЗЗСЦГ : зборник радова",
title = "Ispitivanje valjanosti podataka o jačini doze dobijenih iz civilnih mreža, Evaluation of dose rate data provided by non-governmental networks",
pages = "297-303",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8703"
}
Živanović, M. Z., Kržanović, N., Iurlaro, G., Bell, S., Morosh, V., Đaletić, M.,& Pantelić, G. K.. (2019). Ispitivanje valjanosti podataka o jačini doze dobijenih iz civilnih mreža. in 30. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 297-303.
https://hdl.handle.net/21.15107/rcub_vinar_8703
Živanović MZ, Kržanović N, Iurlaro G, Bell S, Morosh V, Đaletić M, Pantelić GK. Ispitivanje valjanosti podataka o jačini doze dobijenih iz civilnih mreža. in 30. симпозијум ДЗЗСЦГ : зборник радова. 2019;:297-303.
https://hdl.handle.net/21.15107/rcub_vinar_8703 .
Živanović, Miloš Z., Kržanović, Nikola, Iurlaro, Giorgia, Bell, Steven, Morosh, Viacheslav, Đaletić, Miloš, Pantelić, Gordana K., "Ispitivanje valjanosti podataka o jačini doze dobijenih iz civilnih mreža" in 30. симпозијум ДЗЗСЦГ : зборник радова (2019):297-303,
https://hdl.handle.net/21.15107/rcub_vinar_8703 .

Evaluaton of dose rate data provided by non-governmental networks

Živanović, Miloš; Kržanović, Nikola; Iurlaro, Giorgia; Bell, Steven; Morosh, Viacheslav; Đaletić, Miloš; Pantelić, Gordana

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2019)

TY  - CONF
AU  - Živanović, Miloš
AU  - Kržanović, Nikola
AU  - Iurlaro, Giorgia
AU  - Bell, Steven
AU  - Morosh, Viacheslav
AU  - Đaletić, Miloš
AU  - Pantelić, Gordana
PY  - 2019
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11922
AB  - In recent years, the number of non-governmental networks providing quasi real time dose rates is growing. This data is available to the general public via open access based platforms on the internet. The research on the non-governmental networks is scarce and the measurements represented there are mostly carried out using broadly available commercial simple hand-held devices. Without proper testing of these devices in metrological laboratories, there is a significant possibility for discrepancies between the official and non-governmental data, which may have wider implications. Within project 16ENV04 Preparedness, a systematic study of non-governmental networks produced a list of 16 types of dosimeters that are commonly used. Four dosimeters of each type were sourced and commissioned by project partners and are currently undergoing the testing. Test procedures are shortly described in this paper and preliminary results for 2 types of dosimeters are presented.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 30. симпозијум ДЗЗСЦГ : зборник радова
T1  - Evaluaton of dose rate data provided by non-governmental networks
SP  - 297
EP  - 302
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11922
ER  - 
@conference{
author = "Živanović, Miloš and Kržanović, Nikola and Iurlaro, Giorgia and Bell, Steven and Morosh, Viacheslav and Đaletić, Miloš and Pantelić, Gordana",
year = "2019",
abstract = "In recent years, the number of non-governmental networks providing quasi real time dose rates is growing. This data is available to the general public via open access based platforms on the internet. The research on the non-governmental networks is scarce and the measurements represented there are mostly carried out using broadly available commercial simple hand-held devices. Without proper testing of these devices in metrological laboratories, there is a significant possibility for discrepancies between the official and non-governmental data, which may have wider implications. Within project 16ENV04 Preparedness, a systematic study of non-governmental networks produced a list of 16 types of dosimeters that are commonly used. Four dosimeters of each type were sourced and commissioned by project partners and are currently undergoing the testing. Test procedures are shortly described in this paper and preliminary results for 2 types of dosimeters are presented.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "30. симпозијум ДЗЗСЦГ : зборник радова",
title = "Evaluaton of dose rate data provided by non-governmental networks",
pages = "297-302",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11922"
}
Živanović, M., Kržanović, N., Iurlaro, G., Bell, S., Morosh, V., Đaletić, M.,& Pantelić, G.. (2019). Evaluaton of dose rate data provided by non-governmental networks. in 30. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 297-302.
https://hdl.handle.net/21.15107/rcub_vinar_11922
Živanović M, Kržanović N, Iurlaro G, Bell S, Morosh V, Đaletić M, Pantelić G. Evaluaton of dose rate data provided by non-governmental networks. in 30. симпозијум ДЗЗСЦГ : зборник радова. 2019;:297-302.
https://hdl.handle.net/21.15107/rcub_vinar_11922 .
Živanović, Miloš, Kržanović, Nikola, Iurlaro, Giorgia, Bell, Steven, Morosh, Viacheslav, Đaletić, Miloš, Pantelić, Gordana, "Evaluaton of dose rate data provided by non-governmental networks" in 30. симпозијум ДЗЗСЦГ : зборник радова (2019):297-302,
https://hdl.handle.net/21.15107/rcub_vinar_11922 .