Lazović, Ivan

Link to this page

Authority KeyName Variants
orcid::0000-0002-3877-5157
  • Lazović, Ivan (27)
Projects
Evaluation of energy performances and indoor environment quality of educational buildings in Serbia with impact to health Pollution Reduction from Thermal Power Plants of the Public Enterprise “Electric Power Industry of Serbia”
Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 451-03-68/2020-14/200017 (University of Belgrade, Institute of Nuclear Sciences 'Vinča', Belgrade-Vinča) Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 451-03-68/2020-14/200052 (Mining and Metallurgy Institute, Bor)
Domestic Lignite Quality and Combustion Technology Enhancement for Energy Efficiency Increase and Reduction of Harmful Gases and Particulate Matter Emissions from Thermal Power Plants of Public Enterprise ”Electric Power Industry of Serbia” Ministry of Education, Science and Technological Development of the Republic of Serbia
European Commission 6th FP through the Marie Curie Actions project INECSE (Early Stage Research Training in Integrated Energy Conversion for a Sustainable Environment) [MEST-CT-2005-021018] H2020 - VIDIS [GA 952433]
Public health impacts in URban environments of Greenhouse gas Emissions reduction strategies Development of sensor-based Citizens' Observatory Community for improving quality of life in cities
Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 451-03-68/2020-14/200148 (Univeristy of Niš, Faculty of Occupational Safety) Development of new meteorological mast for turbulence parameters characterization
Development and application of distributed system for monitoring and control of electrical energy consumption for large consumers Research and development of alternative fuel and drive systems for urban buses and refuse vehicles with regard to the improvements of energy efficiency and environmental characteristics
Ministry of Education, Science and Technological Development of Republic of Serbia Ministry of Education, Science and Technological Development of the Republic of Serbia [600-00-00557/2013-09/07]
Ministry of Education, Science and Technological Development of the Republic of Serbia [Grant No. 1002205] Ministry of Education, Science & Technological Development, Serbia
Public Enterprise Electric power industry of Serbia, Belgrade, Serbia Research Fund for Coal and Steel project: Application of the biomass, oxyfuel and flameless combustion for the utilisation of pulverised coals for electricity generation (BOFCom) [RFCR-CT-2006-00010]
United Nations Development Programme (UNDP) Serbia

Author's Bibliography

Transfer Learning with ResNet3D-101 for Global Prediction of High Aerosol Concentrations

Nikezić, Dušan P.; Radivojević, Dušan S.; Lazović, Ivan; Mirkov, Nikola S.; Marković, Zoran J.

(2024)

TY  - JOUR
AU  - Nikezić, Dušan P.
AU  - Radivojević, Dušan S.
AU  - Lazović, Ivan
AU  - Mirkov, Nikola S.
AU  - Marković, Zoran J.
PY  - 2024
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12988
AB  - In order to better predict the high aerosol concentrations associated with air pollution and climate change, a machine learning model was developed using transfer learning and the segmentation process of global satellite images. The main concept of transfer learning lies on convolutional neural networks and works by initializing the already trained model weights to better adapt the weights when the network is trained on a different dataset. The transfer learning technique was tested with the ResNet3D-101 model pre-trained from a 2D ImageNet dataset. This model has performed well for contrail detection to assess climate impact. Aerosol distributions can be monitored via satellite remote sensing. Satellites can monitor some aerosol optical properties like aerosol optical thickness. Aerosol optical thickness snapshots were the input dataset for the model and were obtained from NASA’s Terra-Modis satellite; the output images were segmented by comparing the pixel values with a threshold value of 0.8 for aerosol optical thickness. Hyperparameter optimization finds a tuple of hyperparameters that yields an optimal model that minimizes a predefined loss function on given independent data. The model structure was adjusted in order to improve the performance of the model by applying methods and hyperparameter optimization techniques such as grid search, batch size, threshold, and input length. According to the criteria defined by the authors, the distance domain criterion and time domain criterion, the developed model is capable of generating adequate data and finding patterns in the time domain. As observed from the comparison of relative coefficients for the criteria metrics proposed by the authors, ddc and dtc, the deep learning model based on ConvLSTM layers developed in our previous studies has better performance than the model developed in this study with transfer learning.
T2  - Mathematics
T1  - Transfer Learning with ResNet3D-101 for Global Prediction of High Aerosol Concentrations
VL  - 12
IS  - 6
SP  - 826
DO  - 10.3390/math12060826
ER  - 
@article{
author = "Nikezić, Dušan P. and Radivojević, Dušan S. and Lazović, Ivan and Mirkov, Nikola S. and Marković, Zoran J.",
year = "2024",
abstract = "In order to better predict the high aerosol concentrations associated with air pollution and climate change, a machine learning model was developed using transfer learning and the segmentation process of global satellite images. The main concept of transfer learning lies on convolutional neural networks and works by initializing the already trained model weights to better adapt the weights when the network is trained on a different dataset. The transfer learning technique was tested with the ResNet3D-101 model pre-trained from a 2D ImageNet dataset. This model has performed well for contrail detection to assess climate impact. Aerosol distributions can be monitored via satellite remote sensing. Satellites can monitor some aerosol optical properties like aerosol optical thickness. Aerosol optical thickness snapshots were the input dataset for the model and were obtained from NASA’s Terra-Modis satellite; the output images were segmented by comparing the pixel values with a threshold value of 0.8 for aerosol optical thickness. Hyperparameter optimization finds a tuple of hyperparameters that yields an optimal model that minimizes a predefined loss function on given independent data. The model structure was adjusted in order to improve the performance of the model by applying methods and hyperparameter optimization techniques such as grid search, batch size, threshold, and input length. According to the criteria defined by the authors, the distance domain criterion and time domain criterion, the developed model is capable of generating adequate data and finding patterns in the time domain. As observed from the comparison of relative coefficients for the criteria metrics proposed by the authors, ddc and dtc, the deep learning model based on ConvLSTM layers developed in our previous studies has better performance than the model developed in this study with transfer learning.",
journal = "Mathematics",
title = "Transfer Learning with ResNet3D-101 for Global Prediction of High Aerosol Concentrations",
volume = "12",
number = "6",
pages = "826",
doi = "10.3390/math12060826"
}
Nikezić, D. P., Radivojević, D. S., Lazović, I., Mirkov, N. S.,& Marković, Z. J.. (2024). Transfer Learning with ResNet3D-101 for Global Prediction of High Aerosol Concentrations. in Mathematics, 12(6), 826.
https://doi.org/10.3390/math12060826
Nikezić DP, Radivojević DS, Lazović I, Mirkov NS, Marković ZJ. Transfer Learning with ResNet3D-101 for Global Prediction of High Aerosol Concentrations. in Mathematics. 2024;12(6):826.
doi:10.3390/math12060826 .
Nikezić, Dušan P., Radivojević, Dušan S., Lazović, Ivan, Mirkov, Nikola S., Marković, Zoran J., "Transfer Learning with ResNet3D-101 for Global Prediction of High Aerosol Concentrations" in Mathematics, 12, no. 6 (2024):826,
https://doi.org/10.3390/math12060826 . .

Uređaj za merenje kvaliteta vazduha - PAQMAN 2020

Tasić, Viša; Kovačević, Renata; Apostolovski-Trujić, Tatjana; Lazović, Ivan; Mirkov, Nikola; Topalović, Dušan; Božilov, Aca; Mišić, Nikola

(2023)


                                            

                                            
Tasić, V., Kovačević, R., Apostolovski-Trujić, T., Lazović, I., Mirkov, N., Topalović, D., Božilov, A.,& Mišić, N.. (2023). Uređaj za merenje kvaliteta vazduha - PAQMAN 2020. in Univerzitet u Beogradu : Institut za nuklearne nauke "Vinča" - Institut od nacionalnog značaja za Republiku Srbiju.
https://hdl.handle.net/21.15107/rcub_vinar_13000
Tasić V, Kovačević R, Apostolovski-Trujić T, Lazović I, Mirkov N, Topalović D, Božilov A, Mišić N. Uređaj za merenje kvaliteta vazduha - PAQMAN 2020. in Univerzitet u Beogradu : Institut za nuklearne nauke "Vinča" - Institut od nacionalnog značaja za Republiku Srbiju. 2023;.
https://hdl.handle.net/21.15107/rcub_vinar_13000 .
Tasić, Viša, Kovačević, Renata, Apostolovski-Trujić, Tatjana, Lazović, Ivan, Mirkov, Nikola, Topalović, Dušan, Božilov, Aca, Mišić, Nikola, "Uređaj za merenje kvaliteta vazduha - PAQMAN 2020" in Univerzitet u Beogradu : Institut za nuklearne nauke "Vinča" - Institut od nacionalnog značaja za Republiku Srbiju (2023),
https://hdl.handle.net/21.15107/rcub_vinar_13000 .

A Comparative Evaluation of Self-Attention Mechanism with ConvLSTM Model for Global Aerosol Time Series Forecasting

Radivojević, Dušan S.; Lazović, Ivan; Mirkov, Nikola S.; Ramadani, Uzahir; Nikezić, Dušan P.

(2023)

TY  - JOUR
AU  - Radivojević, Dušan S.
AU  - Lazović, Ivan
AU  - Mirkov, Nikola S.
AU  - Ramadani, Uzahir
AU  - Nikezić, Dušan P.
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10871
AB  - The attention mechanism in natural language processing and self-attention mechanism in vision transformers improved many deep learning models. An implementation of the self-attention mechanism with the previously developed ConvLSTM sequence-to-one model was done in order to make a comparative evaluation with statistical testing. First, the new ConvLSTM sequence-to-one model with a self-attention mechanism was developed and then the self-attention layer was removed in order to make comparison. The hyperparameters optimization process was conducted by grid search for integer and string type parameters, and with particle swarm optimization for float type parameters. A cross validation technique was used for better evaluating models with a predefined ratio of train-validation-test subsets. Both models with and without a self-attention layer passed defined evaluation criteria that means that models are able to generate the image of the global aerosol thickness and able to find patterns for changes in the time domain. The model obtained by an ablation study on the self-attention layer achieved better outcomes for Root Mean Square Error and Euclidean Distance in regards to developed ConvLSTM-SA model. As part of the statistical test, a Kruskal–Wallis H Test was done since it was determined that the data did not belong to the normal distribution and the obtained results showed that both models, with and without the SA layer, predict similar images with patterns at the pixel level to the original dataset. However, the model without the SA layer was more similar to the original dataset especially in the time domain at the pixel level. Based on the comparative evaluation with statistical testing, it was concluded that the developed ConvLSTM-SA model better predicts without an SA layer.
T2  - Mathematics
T1  - A Comparative Evaluation of Self-Attention Mechanism with ConvLSTM Model for Global Aerosol Time Series Forecasting
VL  - 11
IS  - 7
SP  - 1744
DO  - 10.3390/math11071744
ER  - 
@article{
author = "Radivojević, Dušan S. and Lazović, Ivan and Mirkov, Nikola S. and Ramadani, Uzahir and Nikezić, Dušan P.",
year = "2023",
abstract = "The attention mechanism in natural language processing and self-attention mechanism in vision transformers improved many deep learning models. An implementation of the self-attention mechanism with the previously developed ConvLSTM sequence-to-one model was done in order to make a comparative evaluation with statistical testing. First, the new ConvLSTM sequence-to-one model with a self-attention mechanism was developed and then the self-attention layer was removed in order to make comparison. The hyperparameters optimization process was conducted by grid search for integer and string type parameters, and with particle swarm optimization for float type parameters. A cross validation technique was used for better evaluating models with a predefined ratio of train-validation-test subsets. Both models with and without a self-attention layer passed defined evaluation criteria that means that models are able to generate the image of the global aerosol thickness and able to find patterns for changes in the time domain. The model obtained by an ablation study on the self-attention layer achieved better outcomes for Root Mean Square Error and Euclidean Distance in regards to developed ConvLSTM-SA model. As part of the statistical test, a Kruskal–Wallis H Test was done since it was determined that the data did not belong to the normal distribution and the obtained results showed that both models, with and without the SA layer, predict similar images with patterns at the pixel level to the original dataset. However, the model without the SA layer was more similar to the original dataset especially in the time domain at the pixel level. Based on the comparative evaluation with statistical testing, it was concluded that the developed ConvLSTM-SA model better predicts without an SA layer.",
journal = "Mathematics",
title = "A Comparative Evaluation of Self-Attention Mechanism with ConvLSTM Model for Global Aerosol Time Series Forecasting",
volume = "11",
number = "7",
pages = "1744",
doi = "10.3390/math11071744"
}
Radivojević, D. S., Lazović, I., Mirkov, N. S., Ramadani, U.,& Nikezić, D. P.. (2023). A Comparative Evaluation of Self-Attention Mechanism with ConvLSTM Model for Global Aerosol Time Series Forecasting. in Mathematics, 11(7), 1744.
https://doi.org/10.3390/math11071744
Radivojević DS, Lazović I, Mirkov NS, Ramadani U, Nikezić DP. A Comparative Evaluation of Self-Attention Mechanism with ConvLSTM Model for Global Aerosol Time Series Forecasting. in Mathematics. 2023;11(7):1744.
doi:10.3390/math11071744 .
Radivojević, Dušan S., Lazović, Ivan, Mirkov, Nikola S., Ramadani, Uzahir, Nikezić, Dušan P., "A Comparative Evaluation of Self-Attention Mechanism with ConvLSTM Model for Global Aerosol Time Series Forecasting" in Mathematics, 11, no. 7 (2023):1744,
https://doi.org/10.3390/math11071744 . .
1

Optimization of the flue gas-flow controlling devices of the electrostatic precipitator of unit A4 in TPP "Nikola Tesla"

Marković, Zoran; Erić, Milić; Stefanović, Predrag; Jovanović, Rastko; Lazović, Ivan

(2023)

TY  - JOUR
AU  - Marković, Zoran
AU  - Erić, Milić
AU  - Stefanović, Predrag
AU  - Jovanović, Rastko
AU  - Lazović, Ivan
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11992
AB  - Homogeneity of the flue gas-flow through the chamber of an electrostatic precipitator is one of the basic influencing parameter on dedusting efficiency. This paper presents results of a multiobjective optimization study of the flue gas controlling devices of electrostatic precipitator of 324 MWe lignite fired Unit A4 of TPP "Nikola Tesla" in Serbia. The aim was to achieve better flow homogeneity in the cross-section of the precipitator compared to the original design. Additional constraints were to maintain the minimum as possible overall weight of the proposed design as well as pressure drop through the precipitator. Numerical simulations based on CFD were used to investigate dependence of the velocity distribution in the ducts and precipitator’s chamber with respect to the geometrical parameters of tested concepts of turning blades. A series of 22 detailed full-scale numerical models of the precipitator with different concepts of turning vanes designs were developed. Assessment of the flow field uniformity for each tested design was performed based on the analysis of several homogeneity parameters calculated for selected vertical cross-sections of the precipitator. After the reconstruction according to optimized design, results of measurements confirmed significant improvements of the velocity distribution in the vertical cross-sections of the precipitator, increase of dedusting efficiency and reduction of PM emission.
T2  - Thermal Science
T1  - Optimization of the flue gas-flow controlling devices of the electrostatic precipitator of unit A4 in TPP "Nikola Tesla"
VL  - 27
IS  - 5 Part A
SP  - 3591
EP  - 3606
DO  - 10.2298/TSCI220903024M
ER  - 
@article{
author = "Marković, Zoran and Erić, Milić and Stefanović, Predrag and Jovanović, Rastko and Lazović, Ivan",
year = "2023",
abstract = "Homogeneity of the flue gas-flow through the chamber of an electrostatic precipitator is one of the basic influencing parameter on dedusting efficiency. This paper presents results of a multiobjective optimization study of the flue gas controlling devices of electrostatic precipitator of 324 MWe lignite fired Unit A4 of TPP "Nikola Tesla" in Serbia. The aim was to achieve better flow homogeneity in the cross-section of the precipitator compared to the original design. Additional constraints were to maintain the minimum as possible overall weight of the proposed design as well as pressure drop through the precipitator. Numerical simulations based on CFD were used to investigate dependence of the velocity distribution in the ducts and precipitator’s chamber with respect to the geometrical parameters of tested concepts of turning blades. A series of 22 detailed full-scale numerical models of the precipitator with different concepts of turning vanes designs were developed. Assessment of the flow field uniformity for each tested design was performed based on the analysis of several homogeneity parameters calculated for selected vertical cross-sections of the precipitator. After the reconstruction according to optimized design, results of measurements confirmed significant improvements of the velocity distribution in the vertical cross-sections of the precipitator, increase of dedusting efficiency and reduction of PM emission.",
journal = "Thermal Science",
title = "Optimization of the flue gas-flow controlling devices of the electrostatic precipitator of unit A4 in TPP "Nikola Tesla"",
volume = "27",
number = "5 Part A",
pages = "3591-3606",
doi = "10.2298/TSCI220903024M"
}
Marković, Z., Erić, M., Stefanović, P., Jovanović, R.,& Lazović, I.. (2023). Optimization of the flue gas-flow controlling devices of the electrostatic precipitator of unit A4 in TPP "Nikola Tesla". in Thermal Science, 27(5 Part A), 3591-3606.
https://doi.org/10.2298/TSCI220903024M
Marković Z, Erić M, Stefanović P, Jovanović R, Lazović I. Optimization of the flue gas-flow controlling devices of the electrostatic precipitator of unit A4 in TPP "Nikola Tesla". in Thermal Science. 2023;27(5 Part A):3591-3606.
doi:10.2298/TSCI220903024M .
Marković, Zoran, Erić, Milić, Stefanović, Predrag, Jovanović, Rastko, Lazović, Ivan, "Optimization of the flue gas-flow controlling devices of the electrostatic precipitator of unit A4 in TPP "Nikola Tesla"" in Thermal Science, 27, no. 5 Part A (2023):3591-3606,
https://doi.org/10.2298/TSCI220903024M . .

Unapređena aparatura za sušenje niskokvalitetnih uglјeva do ravnotežne vlažnosti u nepokretnom i fluidizivanom sloju

Erić, Milić; Marković, Zoran J.; Lazović, Ivan; Jovanović, Rastko; Mladenović, Milica

(2022)


                                            

                                            
Erić, M., Marković, Z. J., Lazović, I., Jovanović, R.,& Mladenović, M.. (2022). Unapređena aparatura za sušenje niskokvalitetnih uglјeva do ravnotežne vlažnosti u nepokretnom i fluidizivanom sloju. in Univerzitet u Beogradu : Institut za nuklearne nauke "Vinča" - Institut od nacionalnog značaja za Republiku Srbiju.
https://hdl.handle.net/21.15107/rcub_vinar_12525
Erić M, Marković ZJ, Lazović I, Jovanović R, Mladenović M. Unapređena aparatura za sušenje niskokvalitetnih uglјeva do ravnotežne vlažnosti u nepokretnom i fluidizivanom sloju. in Univerzitet u Beogradu : Institut za nuklearne nauke "Vinča" - Institut od nacionalnog značaja za Republiku Srbiju. 2022;.
https://hdl.handle.net/21.15107/rcub_vinar_12525 .
Erić, Milić, Marković, Zoran J., Lazović, Ivan, Jovanović, Rastko, Mladenović, Milica, "Unapređena aparatura za sušenje niskokvalitetnih uglјeva do ravnotežne vlažnosti u nepokretnom i fluidizivanom sloju" in Univerzitet u Beogradu : Institut za nuklearne nauke "Vinča" - Institut od nacionalnog značaja za Republiku Srbiju (2022),
https://hdl.handle.net/21.15107/rcub_vinar_12525 .

The efficiency of gas-filled surge arresters in the environment contaminated by non-ionizing radiation of fusion reactors

Aranđelović, Nemanja; Nikezić, Dušan P.; Ramadani, Uzahir; Lazović, Ivan; Mirkov, Nikola S.; Osmokrović, Predrag V.

(2022)

TY  - JOUR
AU  - Aranđelović, Nemanja
AU  - Nikezić, Dušan P.
AU  - Ramadani, Uzahir
AU  - Lazović, Ivan
AU  - Mirkov, Nikola S.
AU  - Osmokrović, Predrag V.
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10435
AB  - The research presents an experiment with a model of an electronic generator for energy injection into the plasma of a fusion reactor. By recording a non-ionizing field in the vicinity of a fusion reactor, it was determined that this field has an extremely high growth rate. At the site of the maximum intensity of the field of non-ionizing radiation, commercial surge arresters with a flexible model of surge arresters were used for experimentation. It has been found that the commercial surge arresters have an efficiency of about 20%. For the efficiency of the flexible model, it was found to be slightly less than 40% (and to be achieved by the application of alpha particle radiation). Since neither of these efficiencies guarantee reliable operation of the gas-filled surge arrester, it was concluded that essential electronics in the vicinity of the fusion generator must be protected. However, since this protection can only be implemented in a fusion reactor, the fact remains that the environment of such a reactor is extremely contaminated with non-ionizing radiation. Commercial surge voltages are isolated for testing since the protection of electronic circuits from fast overvoltages is a critical point for the functioning of modern electronics.
T2  - Nuclear Technology and Radiation Protection
T1  - The efficiency of gas-filled surge arresters in the environment contaminated by non-ionizing radiation of fusion reactors
VL  - 37
IS  - 1
SP  - 51
EP  - 56
DO  - 10.2298/NTRP2201051A
ER  - 
@article{
author = "Aranđelović, Nemanja and Nikezić, Dušan P. and Ramadani, Uzahir and Lazović, Ivan and Mirkov, Nikola S. and Osmokrović, Predrag V.",
year = "2022",
abstract = "The research presents an experiment with a model of an electronic generator for energy injection into the plasma of a fusion reactor. By recording a non-ionizing field in the vicinity of a fusion reactor, it was determined that this field has an extremely high growth rate. At the site of the maximum intensity of the field of non-ionizing radiation, commercial surge arresters with a flexible model of surge arresters were used for experimentation. It has been found that the commercial surge arresters have an efficiency of about 20%. For the efficiency of the flexible model, it was found to be slightly less than 40% (and to be achieved by the application of alpha particle radiation). Since neither of these efficiencies guarantee reliable operation of the gas-filled surge arrester, it was concluded that essential electronics in the vicinity of the fusion generator must be protected. However, since this protection can only be implemented in a fusion reactor, the fact remains that the environment of such a reactor is extremely contaminated with non-ionizing radiation. Commercial surge voltages are isolated for testing since the protection of electronic circuits from fast overvoltages is a critical point for the functioning of modern electronics.",
journal = "Nuclear Technology and Radiation Protection",
title = "The efficiency of gas-filled surge arresters in the environment contaminated by non-ionizing radiation of fusion reactors",
volume = "37",
number = "1",
pages = "51-56",
doi = "10.2298/NTRP2201051A"
}
Aranđelović, N., Nikezić, D. P., Ramadani, U., Lazović, I., Mirkov, N. S.,& Osmokrović, P. V.. (2022). The efficiency of gas-filled surge arresters in the environment contaminated by non-ionizing radiation of fusion reactors. in Nuclear Technology and Radiation Protection, 37(1), 51-56.
https://doi.org/10.2298/NTRP2201051A
Aranđelović N, Nikezić DP, Ramadani U, Lazović I, Mirkov NS, Osmokrović PV. The efficiency of gas-filled surge arresters in the environment contaminated by non-ionizing radiation of fusion reactors. in Nuclear Technology and Radiation Protection. 2022;37(1):51-56.
doi:10.2298/NTRP2201051A .
Aranđelović, Nemanja, Nikezić, Dušan P., Ramadani, Uzahir, Lazović, Ivan, Mirkov, Nikola S., Osmokrović, Predrag V., "The efficiency of gas-filled surge arresters in the environment contaminated by non-ionizing radiation of fusion reactors" in Nuclear Technology and Radiation Protection, 37, no. 1 (2022):51-56,
https://doi.org/10.2298/NTRP2201051A . .
5
6

Deep Learning Model for Global Spatio-Temporal Image Prediction

Nikezić, Dušan P.; Ramadani, Uzahir; Radivojević, Dušan; Lazović, Ivan; Mirkov, Nikola S.

(2022)

TY  - JOUR
AU  - Nikezić, Dušan P.
AU  - Ramadani, Uzahir
AU  - Radivojević, Dušan
AU  - Lazović, Ivan
AU  - Mirkov, Nikola S.
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10446
AB  - Mathematical methods are the basis of most models that describe the natural phenomena around us. However, the well-known conventional mathematical models for atmospheric modeling have some limitations. Machine learning with Big Data is also based on mathematics but offers a new approach for modeling. There are two methodologies to develop deep learning models for spatio-temporal image prediction. On these bases, two models were built—ConvLSTM and CNN-LSTM—with two types of predictions, i.e., sequence-to-sequence and sequence-to-one, in order to forecast Aerosol Optical Thickness sequences. The input dataset for training was NASA satellite imagery MODAL2_E_AER_OD from Terra/MODIS satellites, which presents global Aerosol Optical Thickness with an 8 day temporal resolution from 2000 to the present. The obtained results show that the ConvLSTM sequence-to-one model had the lowest RMSE error and the highest Cosine Similarity value. The advantages of the developed DL models are that they can be executed in milliseconds on a PC, can be used for global-scale Earth observations, and can serve as tracers to study how the Earth’s atmosphere moves. The developed models can be used as transfer learning for similar image time-series forecasting models.
T2  - Mathematics
T1  - Deep Learning Model for Global Spatio-Temporal Image Prediction
VL  - 10
IS  - 18
SP  - 3392
DO  - 10.3390/math10183392
ER  - 
@article{
author = "Nikezić, Dušan P. and Ramadani, Uzahir and Radivojević, Dušan and Lazović, Ivan and Mirkov, Nikola S.",
year = "2022",
abstract = "Mathematical methods are the basis of most models that describe the natural phenomena around us. However, the well-known conventional mathematical models for atmospheric modeling have some limitations. Machine learning with Big Data is also based on mathematics but offers a new approach for modeling. There are two methodologies to develop deep learning models for spatio-temporal image prediction. On these bases, two models were built—ConvLSTM and CNN-LSTM—with two types of predictions, i.e., sequence-to-sequence and sequence-to-one, in order to forecast Aerosol Optical Thickness sequences. The input dataset for training was NASA satellite imagery MODAL2_E_AER_OD from Terra/MODIS satellites, which presents global Aerosol Optical Thickness with an 8 day temporal resolution from 2000 to the present. The obtained results show that the ConvLSTM sequence-to-one model had the lowest RMSE error and the highest Cosine Similarity value. The advantages of the developed DL models are that they can be executed in milliseconds on a PC, can be used for global-scale Earth observations, and can serve as tracers to study how the Earth’s atmosphere moves. The developed models can be used as transfer learning for similar image time-series forecasting models.",
journal = "Mathematics",
title = "Deep Learning Model for Global Spatio-Temporal Image Prediction",
volume = "10",
number = "18",
pages = "3392",
doi = "10.3390/math10183392"
}
Nikezić, D. P., Ramadani, U., Radivojević, D., Lazović, I.,& Mirkov, N. S.. (2022). Deep Learning Model for Global Spatio-Temporal Image Prediction. in Mathematics, 10(18), 3392.
https://doi.org/10.3390/math10183392
Nikezić DP, Ramadani U, Radivojević D, Lazović I, Mirkov NS. Deep Learning Model for Global Spatio-Temporal Image Prediction. in Mathematics. 2022;10(18):3392.
doi:10.3390/math10183392 .
Nikezić, Dušan P., Ramadani, Uzahir, Radivojević, Dušan, Lazović, Ivan, Mirkov, Nikola S., "Deep Learning Model for Global Spatio-Temporal Image Prediction" in Mathematics, 10, no. 18 (2022):3392,
https://doi.org/10.3390/math10183392 . .
3
2

Performance assessment of NOVA SDS011 low-cost PM sensor in various microenvironments

Božilov, Aca; Tasić, Viša; Živković, Nenad; Lazović, Ivan; Blagojević, Milan; Mišić, Nikola; Topalović, Dušan

(2022)

TY  - JOUR
AU  - Božilov, Aca
AU  - Tasić, Viša
AU  - Živković, Nenad
AU  - Lazović, Ivan
AU  - Blagojević, Milan
AU  - Mišić, Nikola
AU  - Topalović, Dušan
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10372
AB  - Over the last 10 years, as a possible alternative to the conventional approach to air quality monitoring, real-time monitoring systems that use low-cost sensors and sensor platforms have been frequently applied. Generally, the long-term characteristics of low-cost PM sensors and monitoring have not been thoroughly documented except for a few widely used sensors and monitors. This article addresses the laboratory and field validation of three low-cost PM monitors of the same type that use the NOVA SDS011 PM sensor module over a 1-year period. In outdoor environments, we co-located low-cost PM monitors with GRIMM EDM180 monitors at the National Air Quality Monitoring stations. In indoor environments, we co-located them with a Turnkey Osiris PM monitor. Several performance aspects of the PM monitors were examined: operational data coverage, linearity of response, accuracy, precision, and inter-sensor variability. The obtained results show that inter-monitor R values were typically higher than 0.95 regardless of the environment. The tested monitors demonstrate high linearity in comparison with PM10 and PM2.5 concentrations measured in outdoor air with reference-equivalent instrumentation with R2 values ranging from 0.52 up to 0.83. In addition, very good agreement (R2 values ranging from 0.93 up to 0.97) with the gravimetric PM10 and PM2.5 method is obtained in the indoor environment (30 < RH < 70%). High RH (over 70%) negatively affected the PM monitors’ response, especially in the case of PM10 concentrations (high overestimation).
T2  - Environmental Monitoring and Assessment
T1  - Performance assessment of NOVA SDS011 low-cost PM sensor in various microenvironments
VL  - 194
IS  - 9
SP  - 595
DO  - 10.1007/s10661-022-10290-7
ER  - 
@article{
author = "Božilov, Aca and Tasić, Viša and Živković, Nenad and Lazović, Ivan and Blagojević, Milan and Mišić, Nikola and Topalović, Dušan",
year = "2022",
abstract = "Over the last 10 years, as a possible alternative to the conventional approach to air quality monitoring, real-time monitoring systems that use low-cost sensors and sensor platforms have been frequently applied. Generally, the long-term characteristics of low-cost PM sensors and monitoring have not been thoroughly documented except for a few widely used sensors and monitors. This article addresses the laboratory and field validation of three low-cost PM monitors of the same type that use the NOVA SDS011 PM sensor module over a 1-year period. In outdoor environments, we co-located low-cost PM monitors with GRIMM EDM180 monitors at the National Air Quality Monitoring stations. In indoor environments, we co-located them with a Turnkey Osiris PM monitor. Several performance aspects of the PM monitors were examined: operational data coverage, linearity of response, accuracy, precision, and inter-sensor variability. The obtained results show that inter-monitor R values were typically higher than 0.95 regardless of the environment. The tested monitors demonstrate high linearity in comparison with PM10 and PM2.5 concentrations measured in outdoor air with reference-equivalent instrumentation with R2 values ranging from 0.52 up to 0.83. In addition, very good agreement (R2 values ranging from 0.93 up to 0.97) with the gravimetric PM10 and PM2.5 method is obtained in the indoor environment (30 < RH < 70%). High RH (over 70%) negatively affected the PM monitors’ response, especially in the case of PM10 concentrations (high overestimation).",
journal = "Environmental Monitoring and Assessment",
title = "Performance assessment of NOVA SDS011 low-cost PM sensor in various microenvironments",
volume = "194",
number = "9",
pages = "595",
doi = "10.1007/s10661-022-10290-7"
}
Božilov, A., Tasić, V., Živković, N., Lazović, I., Blagojević, M., Mišić, N.,& Topalović, D.. (2022). Performance assessment of NOVA SDS011 low-cost PM sensor in various microenvironments. in Environmental Monitoring and Assessment, 194(9), 595.
https://doi.org/10.1007/s10661-022-10290-7
Božilov A, Tasić V, Živković N, Lazović I, Blagojević M, Mišić N, Topalović D. Performance assessment of NOVA SDS011 low-cost PM sensor in various microenvironments. in Environmental Monitoring and Assessment. 2022;194(9):595.
doi:10.1007/s10661-022-10290-7 .
Božilov, Aca, Tasić, Viša, Živković, Nenad, Lazović, Ivan, Blagojević, Milan, Mišić, Nikola, Topalović, Dušan, "Performance assessment of NOVA SDS011 low-cost PM sensor in various microenvironments" in Environmental Monitoring and Assessment, 194, no. 9 (2022):595,
https://doi.org/10.1007/s10661-022-10290-7 . .
3
3

Influence of the building energy efficiency on indoor air temperature: The case of a typical school classroom in Serbia

Lazović, Ivan; Turanjanin, Valentina; Vučićević, Biljana S.; Jovanović, Marina P.; Jovanović, Rastko D.

(2022)

TY  - JOUR
AU  - Lazović, Ivan
AU  - Turanjanin, Valentina
AU  - Vučićević, Biljana S.
AU  - Jovanović, Marina P.
AU  - Jovanović, Rastko D.
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10390
AB  - Greenhouse gases emission as well as total energy consumption in buildings of public importance, such as schools, municipal buildings, health care centers, can be significantly reduced by increasing buildings’ energy efficiency. Buildings’ energy consumption adds up to 37% of total energy consumption in the EU countries. In the Republic of Serbia this amount is significantly higher, about 50%. School buildings are considered as one of the most diverse structures from the point of energy-efficient design and construction. The main aim of this paper is to determine the most appropriate settings for possible improvements in energy efficiency and temperature comfort inside a typical primary school classroom in Serbia. The energy efficiency analysis was performed during the heating season for the naturally ventilated primary school classroom located in the eastern Serbia region. The analysis was performed using novel CFD model, suggested in this paper. The suggested model was used to solve two hypothetical scenarios. The first scenario simulates the temperature field in classroom with current energy characteristic envelope of the school building. The calculated numerical data from the first scenario were compared with in-situ measurements values of temperature and wall heat fluxes and showed satisfying accuracy. The second scenario was simulated to indicate possible improvements, which would allow energy consumption decrease and thermal quality enhancement. The analyzed results, calculated using the suggested numerical model under the second scenario conditions, showed that using appropriate set of measures, it is possible to obtain desired temperature comfort levels without need for increase in the building energy consumption.
T2  - Thermal Science
T1  - Influence of the building energy efficiency on indoor air temperature: The case of a typical school classroom in Serbia
VL  - 26
IS  - 4 Part B
SP  - 3605
EP  - 3618
DO  - 10.2298/TSCI220125067L
ER  - 
@article{
author = "Lazović, Ivan and Turanjanin, Valentina and Vučićević, Biljana S. and Jovanović, Marina P. and Jovanović, Rastko D.",
year = "2022",
abstract = "Greenhouse gases emission as well as total energy consumption in buildings of public importance, such as schools, municipal buildings, health care centers, can be significantly reduced by increasing buildings’ energy efficiency. Buildings’ energy consumption adds up to 37% of total energy consumption in the EU countries. In the Republic of Serbia this amount is significantly higher, about 50%. School buildings are considered as one of the most diverse structures from the point of energy-efficient design and construction. The main aim of this paper is to determine the most appropriate settings for possible improvements in energy efficiency and temperature comfort inside a typical primary school classroom in Serbia. The energy efficiency analysis was performed during the heating season for the naturally ventilated primary school classroom located in the eastern Serbia region. The analysis was performed using novel CFD model, suggested in this paper. The suggested model was used to solve two hypothetical scenarios. The first scenario simulates the temperature field in classroom with current energy characteristic envelope of the school building. The calculated numerical data from the first scenario were compared with in-situ measurements values of temperature and wall heat fluxes and showed satisfying accuracy. The second scenario was simulated to indicate possible improvements, which would allow energy consumption decrease and thermal quality enhancement. The analyzed results, calculated using the suggested numerical model under the second scenario conditions, showed that using appropriate set of measures, it is possible to obtain desired temperature comfort levels without need for increase in the building energy consumption.",
journal = "Thermal Science",
title = "Influence of the building energy efficiency on indoor air temperature: The case of a typical school classroom in Serbia",
volume = "26",
number = "4 Part B",
pages = "3605-3618",
doi = "10.2298/TSCI220125067L"
}
Lazović, I., Turanjanin, V., Vučićević, B. S., Jovanović, M. P.,& Jovanović, R. D.. (2022). Influence of the building energy efficiency on indoor air temperature: The case of a typical school classroom in Serbia. in Thermal Science, 26(4 Part B), 3605-3618.
https://doi.org/10.2298/TSCI220125067L
Lazović I, Turanjanin V, Vučićević BS, Jovanović MP, Jovanović RD. Influence of the building energy efficiency on indoor air temperature: The case of a typical school classroom in Serbia. in Thermal Science. 2022;26(4 Part B):3605-3618.
doi:10.2298/TSCI220125067L .
Lazović, Ivan, Turanjanin, Valentina, Vučićević, Biljana S., Jovanović, Marina P., Jovanović, Rastko D., "Influence of the building energy efficiency on indoor air temperature: The case of a typical school classroom in Serbia" in Thermal Science, 26, no. 4 Part B (2022):3605-3618,
https://doi.org/10.2298/TSCI220125067L . .
2
2

Uređaj sa sigurnosnom membranom – rasprskavajućim diskom ventila sigurnosti

Vašalić, Dragan; Masoničić, Zoran; Lazović, Ivan; Marković, Zoran; Dodić, Boban

(2022)


                                            

                                            
Vašalić, D., Masoničić, Z., Lazović, I., Marković, Z.,& Dodić, B.. (2022). Uređaj sa sigurnosnom membranom – rasprskavajućim diskom ventila sigurnosti. in Institut za nuklearne nauke Vinča : Centar za motore i motorna vozila.
https://hdl.handle.net/21.15107/rcub_vinar_11019
Vašalić D, Masoničić Z, Lazović I, Marković Z, Dodić B. Uređaj sa sigurnosnom membranom – rasprskavajućim diskom ventila sigurnosti. in Institut za nuklearne nauke Vinča : Centar za motore i motorna vozila. 2022;.
https://hdl.handle.net/21.15107/rcub_vinar_11019 .
Vašalić, Dragan, Masoničić, Zoran, Lazović, Ivan, Marković, Zoran, Dodić, Boban, "Uređaj sa sigurnosnom membranom – rasprskavajućim diskom ventila sigurnosti" in Institut za nuklearne nauke Vinča : Centar za motore i motorna vozila (2022),
https://hdl.handle.net/21.15107/rcub_vinar_11019 .

Modelling voluntary general population vaccination strategies during covid-19 outbreak: Influence of disease prevalence

Jovanović, Rastko D.; Davidović, Miloš D.; Lazović, Ivan; Jovanović, Maja; Jovašević-Stojanović, Milena

(2021)

TY  - JOUR
AU  - Jovanović, Rastko D.
AU  - Davidović, Miloš D.
AU  - Lazović, Ivan
AU  - Jovanović, Maja
AU  - Jovašević-Stojanović, Milena
PY  - 2021
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9830
AB  - A novel statistical model based on a two-layer, contact and information, graph is suggested in order to study the influence of disease prevalence on voluntary general population vaccination during the COVID-19 outbreak. Details about the structure and number of susceptible, infectious, and recovered/vaccinated individuals from the contact layer are simultaneously transferred to the information layer. The ever-growing wealth of information that is becoming available about the COVID virus was modelled at each individual level by a simplified proxy predictor of the amount of disease spread. Each informed individual, a node in a heterogeneous graph, makes a decision about vaccination “motivated” by their benefit. The obtained results showed that disease information type, global or local, has a significant impact on an individual vaccination decision. A number of different scenarios were investigated. The scenarios showed that in the case of the stronger impact of globally broadcasted disease information, individuals tend to vaccinate in larger numbers at the same time when the infection has already spread within the population. If individuals make vaccination decisions based on locally available information, the vaccination rate is uniformly spread during infection outbreak duration. Prioritising elderly population vaccination leads to an increased number of infected cases and a higher reduction in mortality. The developed model accuracy allows the precise targeting of vaccination order depending on the individuals’ number of social contacts. Precisely targeted vaccination, combined with pre-existing immunity, and public health measures can limit the infection to isolated hotspots inside the population, as well as significantly delay and lower the infection peak.
T2  - International Journal of Environmental Research and Public Health
T2  - International Journal of Environmental Research and Public Health
T1  - Modelling voluntary general population vaccination strategies during covid-19 outbreak: Influence of disease prevalence
VL  - 18
IS  - 12
SP  - 6217
DO  - 10.3390/ijerph18126217
ER  - 
@article{
author = "Jovanović, Rastko D. and Davidović, Miloš D. and Lazović, Ivan and Jovanović, Maja and Jovašević-Stojanović, Milena",
year = "2021",
abstract = "A novel statistical model based on a two-layer, contact and information, graph is suggested in order to study the influence of disease prevalence on voluntary general population vaccination during the COVID-19 outbreak. Details about the structure and number of susceptible, infectious, and recovered/vaccinated individuals from the contact layer are simultaneously transferred to the information layer. The ever-growing wealth of information that is becoming available about the COVID virus was modelled at each individual level by a simplified proxy predictor of the amount of disease spread. Each informed individual, a node in a heterogeneous graph, makes a decision about vaccination “motivated” by their benefit. The obtained results showed that disease information type, global or local, has a significant impact on an individual vaccination decision. A number of different scenarios were investigated. The scenarios showed that in the case of the stronger impact of globally broadcasted disease information, individuals tend to vaccinate in larger numbers at the same time when the infection has already spread within the population. If individuals make vaccination decisions based on locally available information, the vaccination rate is uniformly spread during infection outbreak duration. Prioritising elderly population vaccination leads to an increased number of infected cases and a higher reduction in mortality. The developed model accuracy allows the precise targeting of vaccination order depending on the individuals’ number of social contacts. Precisely targeted vaccination, combined with pre-existing immunity, and public health measures can limit the infection to isolated hotspots inside the population, as well as significantly delay and lower the infection peak.",
journal = "International Journal of Environmental Research and Public Health, International Journal of Environmental Research and Public Health",
title = "Modelling voluntary general population vaccination strategies during covid-19 outbreak: Influence of disease prevalence",
volume = "18",
number = "12",
pages = "6217",
doi = "10.3390/ijerph18126217"
}
Jovanović, R. D., Davidović, M. D., Lazović, I., Jovanović, M.,& Jovašević-Stojanović, M.. (2021). Modelling voluntary general population vaccination strategies during covid-19 outbreak: Influence of disease prevalence. in International Journal of Environmental Research and Public Health, 18(12), 6217.
https://doi.org/10.3390/ijerph18126217
Jovanović RD, Davidović MD, Lazović I, Jovanović M, Jovašević-Stojanović M. Modelling voluntary general population vaccination strategies during covid-19 outbreak: Influence of disease prevalence. in International Journal of Environmental Research and Public Health. 2021;18(12):6217.
doi:10.3390/ijerph18126217 .
Jovanović, Rastko D., Davidović, Miloš D., Lazović, Ivan, Jovanović, Maja, Jovašević-Stojanović, Milena, "Modelling voluntary general population vaccination strategies during covid-19 outbreak: Influence of disease prevalence" in International Journal of Environmental Research and Public Health, 18, no. 12 (2021):6217,
https://doi.org/10.3390/ijerph18126217 . .
2
2

Characterisation of Fine Particulate Matter Level, Content and Sources of a Kindergarden Microenvironment in Belgrade City Center

Živković, Marija M.; Jovašević-Stojanović, Milena; Cvetković, A.; Lazović, Ivan; Davidović, Miloš D.; Gržetić, I.

(Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences, 2021)

TY  - CONF
AU  - Živković, Marija M.
AU  - Jovašević-Stojanović, Milena
AU  - Cvetković, A.
AU  - Lazović, Ivan
AU  - Davidović, Miloš D.
AU  - Gržetić, I.
PY  - 2021
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10999
PB  - Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences
C3  - WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia
T1  - Characterisation of Fine Particulate Matter Level, Content and Sources of a Kindergarden Microenvironment in Belgrade City Center
SP  - 81
UR  - https://hdl.handle.net/21.15107/rcub_vinar_10999
ER  - 
@conference{
author = "Živković, Marija M. and Jovašević-Stojanović, Milena and Cvetković, A. and Lazović, Ivan and Davidović, Miloš D. and Gržetić, I.",
year = "2021",
publisher = "Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences",
journal = "WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia",
title = "Characterisation of Fine Particulate Matter Level, Content and Sources of a Kindergarden Microenvironment in Belgrade City Center",
pages = "81",
url = "https://hdl.handle.net/21.15107/rcub_vinar_10999"
}
Živković, M. M., Jovašević-Stojanović, M., Cvetković, A., Lazović, I., Davidović, M. D.,& Gržetić, I.. (2021). Characterisation of Fine Particulate Matter Level, Content and Sources of a Kindergarden Microenvironment in Belgrade City Center. in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia
Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences., 81.
https://hdl.handle.net/21.15107/rcub_vinar_10999
Živković MM, Jovašević-Stojanović M, Cvetković A, Lazović I, Davidović MD, Gržetić I. Characterisation of Fine Particulate Matter Level, Content and Sources of a Kindergarden Microenvironment in Belgrade City Center. in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia. 2021;:81.
https://hdl.handle.net/21.15107/rcub_vinar_10999 .
Živković, Marija M., Jovašević-Stojanović, Milena, Cvetković, A., Lazović, Ivan, Davidović, Miloš D., Gržetić, I., "Characterisation of Fine Particulate Matter Level, Content and Sources of a Kindergarden Microenvironment in Belgrade City Center" in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia (2021):81,
https://hdl.handle.net/21.15107/rcub_vinar_10999 .

Numerical Simulation of Gas Flow Through Perforated Plates Inclined to the Main Flow

Marković, Zoran J.; Jovanović, Rastko; Erić, M.; Lazović, Ivan

(Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences, 2021)

TY  - CONF
AU  - Marković, Zoran J.
AU  - Jovanović, Rastko
AU  - Erić, M.
AU  - Lazović, Ivan
PY  - 2021
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11000
PB  - Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences
C3  - WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia
T1  - Numerical Simulation of Gas Flow Through Perforated Plates Inclined to the Main Flow
SP  - 82
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11000
ER  - 
@conference{
author = "Marković, Zoran J. and Jovanović, Rastko and Erić, M. and Lazović, Ivan",
year = "2021",
publisher = "Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences",
journal = "WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia",
title = "Numerical Simulation of Gas Flow Through Perforated Plates Inclined to the Main Flow",
pages = "82",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11000"
}
Marković, Z. J., Jovanović, R., Erić, M.,& Lazović, I.. (2021). Numerical Simulation of Gas Flow Through Perforated Plates Inclined to the Main Flow. in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia
Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences., 82.
https://hdl.handle.net/21.15107/rcub_vinar_11000
Marković ZJ, Jovanović R, Erić M, Lazović I. Numerical Simulation of Gas Flow Through Perforated Plates Inclined to the Main Flow. in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia. 2021;:82.
https://hdl.handle.net/21.15107/rcub_vinar_11000 .
Marković, Zoran J., Jovanović, Rastko, Erić, M., Lazović, Ivan, "Numerical Simulation of Gas Flow Through Perforated Plates Inclined to the Main Flow" in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia (2021):82,
https://hdl.handle.net/21.15107/rcub_vinar_11000 .

Civic Air Quality Monitoring As an Alternative and Supplement to the State Air Quality Monitoring Network

Tasić, V.; Božilov, A.; Lazović, Ivan; Mirkov, Nikola S.; Topalović, Dušan

(Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences, 2021)

TY  - CONF
AU  - Tasić, V.
AU  - Božilov, A.
AU  - Lazović, Ivan
AU  - Mirkov, Nikola S.
AU  - Topalović, Dušan
PY  - 2021
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10993
PB  - Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences
C3  - WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia
T1  - Civic Air Quality Monitoring As an Alternative and Supplement to the State Air Quality Monitoring Network
SP  - 70
UR  - https://hdl.handle.net/21.15107/rcub_vinar_10993
ER  - 
@conference{
author = "Tasić, V. and Božilov, A. and Lazović, Ivan and Mirkov, Nikola S. and Topalović, Dušan",
year = "2021",
publisher = "Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences",
journal = "WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia",
title = "Civic Air Quality Monitoring As an Alternative and Supplement to the State Air Quality Monitoring Network",
pages = "70",
url = "https://hdl.handle.net/21.15107/rcub_vinar_10993"
}
Tasić, V., Božilov, A., Lazović, I., Mirkov, N. S.,& Topalović, D.. (2021). Civic Air Quality Monitoring As an Alternative and Supplement to the State Air Quality Monitoring Network. in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia
Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences., 70.
https://hdl.handle.net/21.15107/rcub_vinar_10993
Tasić V, Božilov A, Lazović I, Mirkov NS, Topalović D. Civic Air Quality Monitoring As an Alternative and Supplement to the State Air Quality Monitoring Network. in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia. 2021;:70.
https://hdl.handle.net/21.15107/rcub_vinar_10993 .
Tasić, V., Božilov, A., Lazović, Ivan, Mirkov, Nikola S., Topalović, Dušan, "Civic Air Quality Monitoring As an Alternative and Supplement to the State Air Quality Monitoring Network" in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia (2021):70,
https://hdl.handle.net/21.15107/rcub_vinar_10993 .

Portable Air Quality Monitor Based on Low-Cost Sensors

Tasić, V.; Božilov, A.; Mišić, N.; Lazović, Ivan; Mirkov, Nikola S.; Topalović, Dušan

(Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences, 2021)

TY  - CONF
AU  - Tasić, V.
AU  - Božilov, A.
AU  - Mišić, N.
AU  - Lazović, Ivan
AU  - Mirkov, Nikola S.
AU  - Topalović, Dušan
PY  - 2021
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10996
PB  - Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences
C3  - WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia
T1  - Portable Air Quality Monitor Based on Low-Cost Sensors
SP  - 75
UR  - https://hdl.handle.net/21.15107/rcub_vinar_10996
ER  - 
@conference{
author = "Tasić, V. and Božilov, A. and Mišić, N. and Lazović, Ivan and Mirkov, Nikola S. and Topalović, Dušan",
year = "2021",
publisher = "Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences",
journal = "WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia",
title = "Portable Air Quality Monitor Based on Low-Cost Sensors",
pages = "75",
url = "https://hdl.handle.net/21.15107/rcub_vinar_10996"
}
Tasić, V., Božilov, A., Mišić, N., Lazović, I., Mirkov, N. S.,& Topalović, D.. (2021). Portable Air Quality Monitor Based on Low-Cost Sensors. in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia
Belgrade : University of Belgrade, Vinča Institute of Nuclear Sciences., 75.
https://hdl.handle.net/21.15107/rcub_vinar_10996
Tasić V, Božilov A, Mišić N, Lazović I, Mirkov NS, Topalović D. Portable Air Quality Monitor Based on Low-Cost Sensors. in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia. 2021;:75.
https://hdl.handle.net/21.15107/rcub_vinar_10996 .
Tasić, V., Božilov, A., Mišić, N., Lazović, Ivan, Mirkov, Nikola S., Topalović, Dušan, "Portable Air Quality Monitor Based on Low-Cost Sensors" in WeBIOPATR 2021 : 8th WeBIOPATR Workshop & Conference: Particulate Matter: Research and Management : Abstracts of Keynote Invited Lectures and Contributed Papers; November 29 - December 1, 2021; Belgrade, Serbia (2021):75,
https://hdl.handle.net/21.15107/rcub_vinar_10996 .

Indoor air pollution, physical and comfort parameters related to schoolchildren's health: Data from the European SINPHONIE study

Baloch, Ramen Munir; Maesano, Cara Nichole; Christoffersen, Jens; Banerjee, Soutrik; Draganic, Jasna; Mogyorosy, Eszter Réka; Korać, Zorica; Jovašević-Stojanović, Milena; Živković, Marija M.; Stevanović, Žarko; Lazović, Ivan; Stevanović, Žana; Živković, Zorica; Cerović, Sofija; Jocić-Stojanović, Jasmina

(2020)

TY  - JOUR
AU  - Baloch, Ramen Munir
AU  - Maesano, Cara Nichole
AU  - Christoffersen, Jens
AU  - Banerjee, Soutrik
AU  - Draganic, Jasna
AU  - Mogyorosy, Eszter Réka
AU  - Korać, Zorica
AU  - Jovašević-Stojanović, Milena
AU  - Živković, Marija M.
AU  - Stevanović, Žarko
AU  - Lazović, Ivan
AU  - Stevanović, Žana
AU  - Živković, Zorica
AU  - Cerović, Sofija
AU  - Jocić-Stojanović, Jasmina
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11620
AB  - Substantial knowledge is available on the association of the indoor school environment and its effect among schoolchildren. In the same context, the SINPHONIE (School indoor pollution and health: Observatory network in Europe) conducted a study to collect data and determine the distribution of several indoor air pollutants (IAPs), physical and thermal parameters and their association with eye, skin, upper-, lower respiratory and systemic disorder symptoms during the previous three months. Finally, data from 115 schools in 54 European cities from 23 countries were collected and included 5175 schoolchildren using a harmonized and standardized protocol. The association between exposures and the health outcomes were examined using logistic regression models on the environmental stressors assessed in classroom while adjusting for several confounding factors; a VOC (volatile organic compound) score defined as the sum of the number of pollutants to which the children were highly exposed (concentration > median of the distribution) in classroom was also introduced to evaluate the mul tiexposu re - outcome association. Schoolchildren while adjusting for several confounding factors. Schoolchildren exposed to above or equal median concentration of PM2.5, benzene, limonene, ozone and radon were at significantly higher odds of suffering from upper, lower airways, eye and systemic disorders. Increased odds were also observed for any symptom (sick school syndrome) among schoolchildren exposed to concentrations of limonene and ozone above median values. Furthermore, the risks for upper and lower airways and systemic disorders significantly increased with the VOCs score. Results also showed that increased ventilation rate was significantly associated with decreased odds of suffering from eye and skin disorders whereas similar association was observed between temperature and upper airways symptoms. The present study provides evidence that exposure to IAPs in schools is associated with various health problems in children. Further investigations are needed to confirm our findings.
T2  - Science of The Total Environment
T1  - Indoor air pollution, physical and comfort parameters related to schoolchildren's health: Data from the European SINPHONIE study
VL  - 739
SP  - 139870
DO  - 10.1016/j.scitotenv.2020.139870
ER  - 
@article{
author = "Baloch, Ramen Munir and Maesano, Cara Nichole and Christoffersen, Jens and Banerjee, Soutrik and Draganic, Jasna and Mogyorosy, Eszter Réka and Korać, Zorica and Jovašević-Stojanović, Milena and Živković, Marija M. and Stevanović, Žarko and Lazović, Ivan and Stevanović, Žana and Živković, Zorica and Cerović, Sofija and Jocić-Stojanović, Jasmina",
year = "2020",
abstract = "Substantial knowledge is available on the association of the indoor school environment and its effect among schoolchildren. In the same context, the SINPHONIE (School indoor pollution and health: Observatory network in Europe) conducted a study to collect data and determine the distribution of several indoor air pollutants (IAPs), physical and thermal parameters and their association with eye, skin, upper-, lower respiratory and systemic disorder symptoms during the previous three months. Finally, data from 115 schools in 54 European cities from 23 countries were collected and included 5175 schoolchildren using a harmonized and standardized protocol. The association between exposures and the health outcomes were examined using logistic regression models on the environmental stressors assessed in classroom while adjusting for several confounding factors; a VOC (volatile organic compound) score defined as the sum of the number of pollutants to which the children were highly exposed (concentration > median of the distribution) in classroom was also introduced to evaluate the mul tiexposu re - outcome association. Schoolchildren while adjusting for several confounding factors. Schoolchildren exposed to above or equal median concentration of PM2.5, benzene, limonene, ozone and radon were at significantly higher odds of suffering from upper, lower airways, eye and systemic disorders. Increased odds were also observed for any symptom (sick school syndrome) among schoolchildren exposed to concentrations of limonene and ozone above median values. Furthermore, the risks for upper and lower airways and systemic disorders significantly increased with the VOCs score. Results also showed that increased ventilation rate was significantly associated with decreased odds of suffering from eye and skin disorders whereas similar association was observed between temperature and upper airways symptoms. The present study provides evidence that exposure to IAPs in schools is associated with various health problems in children. Further investigations are needed to confirm our findings.",
journal = "Science of The Total Environment",
title = "Indoor air pollution, physical and comfort parameters related to schoolchildren's health: Data from the European SINPHONIE study",
volume = "739",
pages = "139870",
doi = "10.1016/j.scitotenv.2020.139870"
}
Baloch, R. M., Maesano, C. N., Christoffersen, J., Banerjee, S., Draganic, J., Mogyorosy, E. R., Korać, Z., Jovašević-Stojanović, M., Živković, M. M., Stevanović, Ž., Lazović, I., Stevanović, Ž., Živković, Z., Cerović, S.,& Jocić-Stojanović, J.. (2020). Indoor air pollution, physical and comfort parameters related to schoolchildren's health: Data from the European SINPHONIE study. in Science of The Total Environment, 739, 139870.
https://doi.org/10.1016/j.scitotenv.2020.139870
Baloch RM, Maesano CN, Christoffersen J, Banerjee S, Draganic J, Mogyorosy ER, Korać Z, Jovašević-Stojanović M, Živković MM, Stevanović Ž, Lazović I, Stevanović Ž, Živković Z, Cerović S, Jocić-Stojanović J. Indoor air pollution, physical and comfort parameters related to schoolchildren's health: Data from the European SINPHONIE study. in Science of The Total Environment. 2020;739:139870.
doi:10.1016/j.scitotenv.2020.139870 .
Baloch, Ramen Munir, Maesano, Cara Nichole, Christoffersen, Jens, Banerjee, Soutrik, Draganic, Jasna, Mogyorosy, Eszter Réka, Korać, Zorica, Jovašević-Stojanović, Milena, Živković, Marija M., Stevanović, Žarko, Lazović, Ivan, Stevanović, Žana, Živković, Zorica, Cerović, Sofija, Jocić-Stojanović, Jasmina, "Indoor air pollution, physical and comfort parameters related to schoolchildren's health: Data from the European SINPHONIE study" in Science of The Total Environment, 739 (2020):139870,
https://doi.org/10.1016/j.scitotenv.2020.139870 . .
9
95
88

Mathematical modelling of swirl oxy-fuel burner flame characteristics

Jovanović, Rastko D.; Swiatkowski, Bartosz; Kakietek, Slawomir; Škobalj, Predrag D.; Lazović, Ivan; Cvetinović, Dejan

(2019)

TY  - JOUR
AU  - Jovanović, Rastko D.
AU  - Swiatkowski, Bartosz
AU  - Kakietek, Slawomir
AU  - Škobalj, Predrag D.
AU  - Lazović, Ivan
AU  - Cvetinović, Dejan
PY  - 2019
UR  - https://linkinghub.elsevier.com/retrieve/pii/S019689041930439X
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8149
AB  - Oxy-fuel combustion is the most promising carbon capture and storage technology, which eliminates carbon dioxide emissions into the atmosphere and also decreases nitrogen oxides emissions thereby lowering global warming potential. In order to implement oxy-fuel combustion technology in full scale power plants, its costs, mainly connected with the amount of pure oxygen produced, must be lowered. The main hypothesis is that it is possible to maintain similar velocity and heat transfer distribution while maintaining stable and efficient burner operation during both combustion technologies modifying burner aerodynamics. Excess oxygen is chosen as a representative parameter of burner's performance and investigation is carried out for four different oxy-fuel burner oxygen excess ratios (λ: 0.8, 0.98, 1.07, and 1.24) together with reference air combustion case. This study suggests a workflow, based on semi-industrial experimental investigations and computational fluid dynamics model composed of advanced sub-models for different combustion phases for development of real scale dual-mode coal swirl burners able for efficient operation during both combustion regimes. The results show that the temperature in near-burner zone and nitrogen oxides emissions increase, while carbon monoxide emissions decrease with the increase of burner oxygen excess ratio, and stable combustion with similar velocity and temperature distributions for both combustion modes is achieved for oxygen excess ratio of 1.07, with decrease in nitrogen oxides and carbon monoxide emissions during oxy-fuel combustion. The performed study demonstrates that it is possible to choose the appropriate burner settings regarding nitrogen oxides and carbon monoxide emissions and burner's ability to operate stably in both air and oxy-fuel combustion modes. © 2019 Elsevier Ltd
T2  - Energy Conversion and Management
T1  - Mathematical modelling of swirl oxy-fuel burner flame characteristics
VL  - 191
SP  - 193
EP  - 207
DO  - 10.1016/j.enconman.2019.04.027
ER  - 
@article{
author = "Jovanović, Rastko D. and Swiatkowski, Bartosz and Kakietek, Slawomir and Škobalj, Predrag D. and Lazović, Ivan and Cvetinović, Dejan",
year = "2019",
abstract = "Oxy-fuel combustion is the most promising carbon capture and storage technology, which eliminates carbon dioxide emissions into the atmosphere and also decreases nitrogen oxides emissions thereby lowering global warming potential. In order to implement oxy-fuel combustion technology in full scale power plants, its costs, mainly connected with the amount of pure oxygen produced, must be lowered. The main hypothesis is that it is possible to maintain similar velocity and heat transfer distribution while maintaining stable and efficient burner operation during both combustion technologies modifying burner aerodynamics. Excess oxygen is chosen as a representative parameter of burner's performance and investigation is carried out for four different oxy-fuel burner oxygen excess ratios (λ: 0.8, 0.98, 1.07, and 1.24) together with reference air combustion case. This study suggests a workflow, based on semi-industrial experimental investigations and computational fluid dynamics model composed of advanced sub-models for different combustion phases for development of real scale dual-mode coal swirl burners able for efficient operation during both combustion regimes. The results show that the temperature in near-burner zone and nitrogen oxides emissions increase, while carbon monoxide emissions decrease with the increase of burner oxygen excess ratio, and stable combustion with similar velocity and temperature distributions for both combustion modes is achieved for oxygen excess ratio of 1.07, with decrease in nitrogen oxides and carbon monoxide emissions during oxy-fuel combustion. The performed study demonstrates that it is possible to choose the appropriate burner settings regarding nitrogen oxides and carbon monoxide emissions and burner's ability to operate stably in both air and oxy-fuel combustion modes. © 2019 Elsevier Ltd",
journal = "Energy Conversion and Management",
title = "Mathematical modelling of swirl oxy-fuel burner flame characteristics",
volume = "191",
pages = "193-207",
doi = "10.1016/j.enconman.2019.04.027"
}
Jovanović, R. D., Swiatkowski, B., Kakietek, S., Škobalj, P. D., Lazović, I.,& Cvetinović, D.. (2019). Mathematical modelling of swirl oxy-fuel burner flame characteristics. in Energy Conversion and Management, 191, 193-207.
https://doi.org/10.1016/j.enconman.2019.04.027
Jovanović RD, Swiatkowski B, Kakietek S, Škobalj PD, Lazović I, Cvetinović D. Mathematical modelling of swirl oxy-fuel burner flame characteristics. in Energy Conversion and Management. 2019;191:193-207.
doi:10.1016/j.enconman.2019.04.027 .
Jovanović, Rastko D., Swiatkowski, Bartosz, Kakietek, Slawomir, Škobalj, Predrag D., Lazović, Ivan, Cvetinović, Dejan, "Mathematical modelling of swirl oxy-fuel burner flame characteristics" in Energy Conversion and Management, 191 (2019):193-207,
https://doi.org/10.1016/j.enconman.2019.04.027 . .
19
11
16

Results of testing of an safety valve with a passive rupture disc of the ic engine exhaust gas conditioning chamber

Vašalić, Dragan; Masoničić, Zoran; Petronjić, Sanja; Lazović, Ivan; Spajić, Branko; Dragutinović, Aleksandar

(2019)

TY  - CONF
AU  - Vašalić, Dragan
AU  - Masoničić, Zoran
AU  - Petronjić, Sanja
AU  - Lazović, Ivan
AU  - Spajić, Branko
AU  - Dragutinović, Aleksandar
PY  - 2019
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10654
AB  - The combination of rupture (bursting) disc and safety valve ensures reliable operation of the valve and overload protection of pressure installations, such as steam generators, chambers, pipelines, and pressure vessels. Certain guidelines for designing and testing safety devices with a bursting disk exist in the literature, but the design of the disc can only be determined experimentally. This paper presents the results of testing of the disc design intended for the use on the IC engine exhaust gass conditioning chamber. It is required that the burst pressure of the disc membrane at a temperature of 950°C has to be 1.05 MPa. A total of 75 samples, of different thicknesses and depths of the disk weakening, at different temperature loads, were examined. It is required that the burst pressure of the disc membrane at a temperature of 950°C has to be 1.05 MPa. A total of 75 samples, of different thicknesses and depths of the disk weakening, at different temperature loads, were examined.
C3  - Young Researches Conference 2019, YOURS 2019, March 26-27, 2019
T1  - Results of testing of an safety valve with a passive rupture disc of the ic engine exhaust gas conditioning chamber
UR  - https://hdl.handle.net/21.15107/rcub_vinar_10654
ER  - 
@conference{
author = "Vašalić, Dragan and Masoničić, Zoran and Petronjić, Sanja and Lazović, Ivan and Spajić, Branko and Dragutinović, Aleksandar",
year = "2019",
abstract = "The combination of rupture (bursting) disc and safety valve ensures reliable operation of the valve and overload protection of pressure installations, such as steam generators, chambers, pipelines, and pressure vessels. Certain guidelines for designing and testing safety devices with a bursting disk exist in the literature, but the design of the disc can only be determined experimentally. This paper presents the results of testing of the disc design intended for the use on the IC engine exhaust gass conditioning chamber. It is required that the burst pressure of the disc membrane at a temperature of 950°C has to be 1.05 MPa. A total of 75 samples, of different thicknesses and depths of the disk weakening, at different temperature loads, were examined. It is required that the burst pressure of the disc membrane at a temperature of 950°C has to be 1.05 MPa. A total of 75 samples, of different thicknesses and depths of the disk weakening, at different temperature loads, were examined.",
journal = "Young Researches Conference 2019, YOURS 2019, March 26-27, 2019",
title = "Results of testing of an safety valve with a passive rupture disc of the ic engine exhaust gas conditioning chamber",
url = "https://hdl.handle.net/21.15107/rcub_vinar_10654"
}
Vašalić, D., Masoničić, Z., Petronjić, S., Lazović, I., Spajić, B.,& Dragutinović, A.. (2019). Results of testing of an safety valve with a passive rupture disc of the ic engine exhaust gas conditioning chamber. in Young Researches Conference 2019, YOURS 2019, March 26-27, 2019.
https://hdl.handle.net/21.15107/rcub_vinar_10654
Vašalić D, Masoničić Z, Petronjić S, Lazović I, Spajić B, Dragutinović A. Results of testing of an safety valve with a passive rupture disc of the ic engine exhaust gas conditioning chamber. in Young Researches Conference 2019, YOURS 2019, March 26-27, 2019. 2019;.
https://hdl.handle.net/21.15107/rcub_vinar_10654 .
Vašalić, Dragan, Masoničić, Zoran, Petronjić, Sanja, Lazović, Ivan, Spajić, Branko, Dragutinović, Aleksandar, "Results of testing of an safety valve with a passive rupture disc of the ic engine exhaust gas conditioning chamber" in Young Researches Conference 2019, YOURS 2019, March 26-27, 2019 (2019),
https://hdl.handle.net/21.15107/rcub_vinar_10654 .

Results of the modernization of the electrostatic precipitator at unit B1 of the Thermal Power Plant Kostolac B

Erić, Milić; Stefanović, Predrag Lj.; Marković, Zoran J.; Jovanović, Rastko D.; Lazović, Ivan; Živković, Nikola V.; Ilić, Željko

(2018)

TY  - JOUR
AU  - Erić, Milić
AU  - Stefanović, Predrag Lj.
AU  - Marković, Zoran J.
AU  - Jovanović, Rastko D.
AU  - Lazović, Ivan
AU  - Živković, Nikola V.
AU  - Ilić, Željko
PY  - 2018
UR  - http://www.doiserbia.nb.rs/Article.aspx?ID=0354-983618623E
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8030
AB  - The electrostatic precipitator system of the lignite fired 350 MWe unit B1 of Thermal Power Plant Kostolac B has been modernized during 2014. The results of complex in site measurements, performed in the frame of performance control test at the beginning of the exploitation period of the upgraded electrostatic pre-cipitator proved that, under normal and guarantee working conditions of the boiler and precipitator, the emission of particulate matter do not exceed limiting value. After the period of precipitator further adjustments, five series of meas-urements in the frame of acceptance test were performed in accordance with rel-evant standards. This paper presents results of the investigation of particulate matter concentration, laboratory analysis of the lignite, fly and bottom ash sam-ples, working parameters of the unit and upgraded electrostatic precipitator as well as results of the calculations. The averaged mean particulate concentration at the exit of upgraded electrostatic precipitator of the unit B1 during Acceptance test was below guaranteed value. It is confirmed that adjustments of electrostatic precipitator electrical parameters have improved electrostatic precipitator effi-ciency, as well that electrostatic precipitatorcould work highly efficiently in en-ergy save mode with lower power consumption. © 2018 Society of Thermal Engineers of Serbia.
T2  - Thermal Science
T1  - Results of the modernization of the electrostatic precipitator at unit B1 of the Thermal Power Plant Kostolac B
VL  - 22
IS  - Suppl. 5
SP  - 1623
EP  - 1634
DO  - 10.2298/TSCI18S5623E
ER  - 
@article{
author = "Erić, Milić and Stefanović, Predrag Lj. and Marković, Zoran J. and Jovanović, Rastko D. and Lazović, Ivan and Živković, Nikola V. and Ilić, Željko",
year = "2018",
abstract = "The electrostatic precipitator system of the lignite fired 350 MWe unit B1 of Thermal Power Plant Kostolac B has been modernized during 2014. The results of complex in site measurements, performed in the frame of performance control test at the beginning of the exploitation period of the upgraded electrostatic pre-cipitator proved that, under normal and guarantee working conditions of the boiler and precipitator, the emission of particulate matter do not exceed limiting value. After the period of precipitator further adjustments, five series of meas-urements in the frame of acceptance test were performed in accordance with rel-evant standards. This paper presents results of the investigation of particulate matter concentration, laboratory analysis of the lignite, fly and bottom ash sam-ples, working parameters of the unit and upgraded electrostatic precipitator as well as results of the calculations. The averaged mean particulate concentration at the exit of upgraded electrostatic precipitator of the unit B1 during Acceptance test was below guaranteed value. It is confirmed that adjustments of electrostatic precipitator electrical parameters have improved electrostatic precipitator effi-ciency, as well that electrostatic precipitatorcould work highly efficiently in en-ergy save mode with lower power consumption. © 2018 Society of Thermal Engineers of Serbia.",
journal = "Thermal Science",
title = "Results of the modernization of the electrostatic precipitator at unit B1 of the Thermal Power Plant Kostolac B",
volume = "22",
number = "Suppl. 5",
pages = "1623-1634",
doi = "10.2298/TSCI18S5623E"
}
Erić, M., Stefanović, P. Lj., Marković, Z. J., Jovanović, R. D., Lazović, I., Živković, N. V.,& Ilić, Ž.. (2018). Results of the modernization of the electrostatic precipitator at unit B1 of the Thermal Power Plant Kostolac B. in Thermal Science, 22(Suppl. 5), 1623-1634.
https://doi.org/10.2298/TSCI18S5623E
Erić M, Stefanović PL, Marković ZJ, Jovanović RD, Lazović I, Živković NV, Ilić Ž. Results of the modernization of the electrostatic precipitator at unit B1 of the Thermal Power Plant Kostolac B. in Thermal Science. 2018;22(Suppl. 5):1623-1634.
doi:10.2298/TSCI18S5623E .
Erić, Milić, Stefanović, Predrag Lj., Marković, Zoran J., Jovanović, Rastko D., Lazović, Ivan, Živković, Nikola V., Ilić, Željko, "Results of the modernization of the electrostatic precipitator at unit B1 of the Thermal Power Plant Kostolac B" in Thermal Science, 22, no. Suppl. 5 (2018):1623-1634,
https://doi.org/10.2298/TSCI18S5623E . .
1
3
3

Assessing the sustainability of Serbian school buildings by ASPID method

Jovanović, Marina P.; Vučićević, Biljana S.; Turanjanin, Valentina; Lazović, Ivan; Živković, Marija M.

(2018)

TY  - JOUR
AU  - Jovanović, Marina P.
AU  - Vučićević, Biljana S.
AU  - Turanjanin, Valentina
AU  - Lazović, Ivan
AU  - Živković, Marija M.
PY  - 2018
UR  - http://www.doiserbia.nb.rs/Article.aspx?ID=0354-98361800131J
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7973
AB  - Sustainable development indicators mainly provide information that can link the observed energy system with sustainable development. This paper considers building energy indicators in order to provide monitoring and measurement of energy performance of buildings. The results of measurement which are considered were obtained in school buildings in Serbia. The aim of this paper is to select, define, and calculate energy indicators as criteria for evaluating the quality of public buildings, with regard to sustainable development. The criteria for assessing sustainability are quantified by certain defined sets of economic, social and environmental indicators. The ASPID method of multi-criteria analysis is also described and mathematically presented. This method is based on the synthesis technique of fuzzy sets and the sustainability of the school buildings was based on their assessment as complex energy systems. © 2018 Serbian Society of Heat Transfer Engineers.
T2  - Thermal Science
T1  - Assessing the sustainability of Serbian school buildings by ASPID method
VL  - 22
IS  - Supl. 4
SP  - 1271
EP  - 1283
DO  - 10.2298/TSCI170529131J
ER  - 
@article{
author = "Jovanović, Marina P. and Vučićević, Biljana S. and Turanjanin, Valentina and Lazović, Ivan and Živković, Marija M.",
year = "2018",
abstract = "Sustainable development indicators mainly provide information that can link the observed energy system with sustainable development. This paper considers building energy indicators in order to provide monitoring and measurement of energy performance of buildings. The results of measurement which are considered were obtained in school buildings in Serbia. The aim of this paper is to select, define, and calculate energy indicators as criteria for evaluating the quality of public buildings, with regard to sustainable development. The criteria for assessing sustainability are quantified by certain defined sets of economic, social and environmental indicators. The ASPID method of multi-criteria analysis is also described and mathematically presented. This method is based on the synthesis technique of fuzzy sets and the sustainability of the school buildings was based on their assessment as complex energy systems. © 2018 Serbian Society of Heat Transfer Engineers.",
journal = "Thermal Science",
title = "Assessing the sustainability of Serbian school buildings by ASPID method",
volume = "22",
number = "Supl. 4",
pages = "1271-1283",
doi = "10.2298/TSCI170529131J"
}
Jovanović, M. P., Vučićević, B. S., Turanjanin, V., Lazović, I.,& Živković, M. M.. (2018). Assessing the sustainability of Serbian school buildings by ASPID method. in Thermal Science, 22(Supl. 4), 1271-1283.
https://doi.org/10.2298/TSCI170529131J
Jovanović MP, Vučićević BS, Turanjanin V, Lazović I, Živković MM. Assessing the sustainability of Serbian school buildings by ASPID method. in Thermal Science. 2018;22(Supl. 4):1271-1283.
doi:10.2298/TSCI170529131J .
Jovanović, Marina P., Vučićević, Biljana S., Turanjanin, Valentina, Lazović, Ivan, Živković, Marija M., "Assessing the sustainability of Serbian school buildings by ASPID method" in Thermal Science, 22, no. Supl. 4 (2018):1271-1283,
https://doi.org/10.2298/TSCI170529131J . .
6
3
5

Ecological and economic aspects of diesel fuel use in the road transport by heavy-duty vehicles in Serbia

Vašalić, Dragan; Lazović, Ivan; Petronić, Sanja; Masoničić, Zoran; Tasić, Viša

(2018)

TY  - CONF
AU  - Vašalić, Dragan
AU  - Lazović, Ivan
AU  - Petronić, Sanja
AU  - Masoničić, Zoran
AU  - Tasić, Viša
PY  - 2018
PY  - 2018
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10492
AB  - Road transport is the significant and inevitable part of the modern society. Its accelerated expansion is recognized as one of the causes for the increased air pollutant emissions (CO, NOx, NMVOC, PM2.5, and CO2). Therefore, the priorities of the future development of heavy-duty vehicles and their equipment are the reduction of the fuel consumption and reduction of the exhaust gases emissions. In this paper, the monitored emissions of heavy-duty vehicles of various technologies, that use diesel as fuel, have been analyzed by using the COPERT program. The analysis shows that Euro 5 vehicles emit 29% less harmful substances compared with Euro 3 vehicles.
C3  - IOC 2018 : 50th International October Conference on Mining and Metallurgy : Proceedings; September 30th - October 3rd, 2018; Bor
T1  - Ecological and economic aspects of diesel fuel use in the road transport by heavy-duty vehicles in Serbia
SP  - 393
EP  - 399
UR  - https://hdl.handle.net/21.15107/rcub_vinar_10492
ER  - 
@conference{
author = "Vašalić, Dragan and Lazović, Ivan and Petronić, Sanja and Masoničić, Zoran and Tasić, Viša",
year = "2018, 2018",
abstract = "Road transport is the significant and inevitable part of the modern society. Its accelerated expansion is recognized as one of the causes for the increased air pollutant emissions (CO, NOx, NMVOC, PM2.5, and CO2). Therefore, the priorities of the future development of heavy-duty vehicles and their equipment are the reduction of the fuel consumption and reduction of the exhaust gases emissions. In this paper, the monitored emissions of heavy-duty vehicles of various technologies, that use diesel as fuel, have been analyzed by using the COPERT program. The analysis shows that Euro 5 vehicles emit 29% less harmful substances compared with Euro 3 vehicles.",
journal = "IOC 2018 : 50th International October Conference on Mining and Metallurgy : Proceedings; September 30th - October 3rd, 2018; Bor",
title = "Ecological and economic aspects of diesel fuel use in the road transport by heavy-duty vehicles in Serbia",
pages = "393-399",
url = "https://hdl.handle.net/21.15107/rcub_vinar_10492"
}
Vašalić, D., Lazović, I., Petronić, S., Masoničić, Z.,& Tasić, V.. (2018). Ecological and economic aspects of diesel fuel use in the road transport by heavy-duty vehicles in Serbia. in IOC 2018 : 50th International October Conference on Mining and Metallurgy : Proceedings; September 30th - October 3rd, 2018; Bor, 393-399.
https://hdl.handle.net/21.15107/rcub_vinar_10492
Vašalić D, Lazović I, Petronić S, Masoničić Z, Tasić V. Ecological and economic aspects of diesel fuel use in the road transport by heavy-duty vehicles in Serbia. in IOC 2018 : 50th International October Conference on Mining and Metallurgy : Proceedings; September 30th - October 3rd, 2018; Bor. 2018;:393-399.
https://hdl.handle.net/21.15107/rcub_vinar_10492 .
Vašalić, Dragan, Lazović, Ivan, Petronić, Sanja, Masoničić, Zoran, Tasić, Viša, "Ecological and economic aspects of diesel fuel use in the road transport by heavy-duty vehicles in Serbia" in IOC 2018 : 50th International October Conference on Mining and Metallurgy : Proceedings; September 30th - October 3rd, 2018; Bor (2018):393-399,
https://hdl.handle.net/21.15107/rcub_vinar_10492 .

Impact of Co2 Concentration on Indoor Air Quality and Correlation with Relative Humidity and Indoor Air Temperature in School Buildings in Serbia

Lazović, Ivan; Stevanović, Žarko M.; Jovašević-Stojanović, Milena; Živković, Marija M.; Banjac, Miloš J.

(2016)

TY  - JOUR
AU  - Lazović, Ivan
AU  - Stevanović, Žarko M.
AU  - Jovašević-Stojanović, Milena
AU  - Živković, Marija M.
AU  - Banjac, Miloš J.
PY  - 2016
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/1152
AB  - Previous studies have shown that poorly ventilated classrooms can have negative impact on the health of children and school staff. In most cases, schools in Serbia are ventilated naturally. Considering their high occupancy, classroom air quality test determines the level of air pollution, after which it is possible to implement corrective measures. The research presented in this study, was conducted in four schools which are located in different areas and have different architecture designs. Measurements in these schools have been performed during the winter (heating season) and spring (non-heating season) and the following results were presented: indoor air temperature, relative humidity, and carbon dioxide concentration. These results show that the classroom average concentration of carbon dioxide often exceeds the value of 1500 ppm, during its full occupancy, which indicates inadequate ventilation. Measurement campaigns show that carbon dioxide concentration increased significantly from non-heating to heating season in three of the four schools. Analysis of measurements also determined high correlation between relative humidity and carbon dioxide concentration in all schools in winter season. This fact may constitute a solid basis for the fresh air supply strategy.
T2  - Thermal Science
T1  - Impact of Co2 Concentration on Indoor Air Quality and Correlation with Relative Humidity and Indoor Air Temperature in School Buildings in Serbia
VL  - 20
SP  - S297
EP  - S307
DO  - 10.2298/TSCI150831173L
ER  - 
@article{
author = "Lazović, Ivan and Stevanović, Žarko M. and Jovašević-Stojanović, Milena and Živković, Marija M. and Banjac, Miloš J.",
year = "2016",
abstract = "Previous studies have shown that poorly ventilated classrooms can have negative impact on the health of children and school staff. In most cases, schools in Serbia are ventilated naturally. Considering their high occupancy, classroom air quality test determines the level of air pollution, after which it is possible to implement corrective measures. The research presented in this study, was conducted in four schools which are located in different areas and have different architecture designs. Measurements in these schools have been performed during the winter (heating season) and spring (non-heating season) and the following results were presented: indoor air temperature, relative humidity, and carbon dioxide concentration. These results show that the classroom average concentration of carbon dioxide often exceeds the value of 1500 ppm, during its full occupancy, which indicates inadequate ventilation. Measurement campaigns show that carbon dioxide concentration increased significantly from non-heating to heating season in three of the four schools. Analysis of measurements also determined high correlation between relative humidity and carbon dioxide concentration in all schools in winter season. This fact may constitute a solid basis for the fresh air supply strategy.",
journal = "Thermal Science",
title = "Impact of Co2 Concentration on Indoor Air Quality and Correlation with Relative Humidity and Indoor Air Temperature in School Buildings in Serbia",
volume = "20",
pages = "S297-S307",
doi = "10.2298/TSCI150831173L"
}
Lazović, I., Stevanović, Ž. M., Jovašević-Stojanović, M., Živković, M. M.,& Banjac, M. J.. (2016). Impact of Co2 Concentration on Indoor Air Quality and Correlation with Relative Humidity and Indoor Air Temperature in School Buildings in Serbia. in Thermal Science, 20, S297-S307.
https://doi.org/10.2298/TSCI150831173L
Lazović I, Stevanović ŽM, Jovašević-Stojanović M, Živković MM, Banjac MJ. Impact of Co2 Concentration on Indoor Air Quality and Correlation with Relative Humidity and Indoor Air Temperature in School Buildings in Serbia. in Thermal Science. 2016;20:S297-S307.
doi:10.2298/TSCI150831173L .
Lazović, Ivan, Stevanović, Žarko M., Jovašević-Stojanović, Milena, Živković, Marija M., Banjac, Miloš J., "Impact of Co2 Concentration on Indoor Air Quality and Correlation with Relative Humidity and Indoor Air Temperature in School Buildings in Serbia" in Thermal Science, 20 (2016):S297-S307,
https://doi.org/10.2298/TSCI150831173L . .
32
16
29

Smanjenje emisije praškastih materija posle rekonstrukcije i modernizacije elektrofilterskih postrojenja na TE „Nikola Tesla B”

Erić, Milić; Stefanović, Predrag; Marković, Zoran; Škobalj, Predrag; Cvetinović, Dejan; Jovanović, Rastko; Lazović, Ivan

(2016)

TY  - JOUR
AU  - Erić, Milić
AU  - Stefanović, Predrag
AU  - Marković, Zoran
AU  - Škobalj, Predrag
AU  - Cvetinović, Dejan
AU  - Jovanović, Rastko
AU  - Lazović, Ivan
PY  - 2016
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12111
AB  - U odgovarajuće propise domaćeg zakonodavstva uključeni su zahtevi iz međunarodnog dokumenta, Direktiva 2001/80/EC, koji se odnose na ograničenje emisije praškastih materija iz velikih termoenergetskih postrojenja. Shodno preuzetim obavezama, od 2005. godine započelo se sa rekonstrukcijama i modernizacijama elektrofilterskih postrojenja svih termoblokova u sastavu JP EPS. Na termoelektrani 'Nikola Tesla B' je tokom 2011. godine izvršena rekonstrukcija i modernizacija elektrofilterskog postrojenja bloka B2, dok je rekonstrukcija elektrofilterskog postrojenja bloka B1 obavljena tokom 2012. godine. Cilj obavljenih rekonstrukcija, finansiranih donacijama Evropske Unije, bio je da se emisija praškastih materija u dimnom gasu iz ovih blokova spusti na nivo ispod 50 mg/Nm3, za normalne uslove i pri garantovanim radnim uslovima kotla i elektrofilterskog postrojenja. U radu su prikazani rezultati merenja koncentracija praškastih materija u dimnom gasu iza elektrofiltera, obavljenih u skladu sa zahtevima međunarodnih standarda ISO 9096 i EN 13284-1 nakon rekonstrukcije elektrofilterskih postrojenja termoelektrane TENT B, kao i rezultati ispitivanja obavljenih nakon isteka perioda od godinu dana od završetka rekonstrukcija. Dobijeni rezultati potvrđuju da je izlazna koncentracija praškastih materija ispod garantovane vrednosti, čime je potvrđena uspešnosti izvedenih rekonstruktivnih zahvata.
AB  - The requirements of the international document Directive 2001/80/EC relating to limitation of the particulate matter emissions from large thermal power plants have been incorporated into relevant regulations of domestic legislation. In accordance with the commitments, since 2005 it was started with reconstruction and modernization of electrostatic precipitator system of all thermal units within the Electric Power Industry of Serbia. The reconstruction and modernization of electrostatic precipitator system of the unit B2 of thermal power plant 'Nikola Tesla B' was done during 2011, while the reconstruction of the electrostatic precipitator system of the unit B1 was conducted in 2012 year. One of the main objectives of performed reconstructions and modernizations, financed by donations of the European Union, was to decrease the emission of particulate matter in the flue gas from these units down to level below 50 mg/Nm3, in normal conditions and under guaranteed operating conditions of the boiler and electrostatic precipitator system. This paper presents results of the measurements of particulate matter concentration performed in accordance with standards ISO 9096 and EN 13284-1, immediately after the reconstruction and shortly before the end of the period of about 1 year after the reconstruction, as a part of control and guarantee investigations of the reconstructed electrostatic precipitators of Thermal Power Plant Nikola Tesla B units. In addition, this paper presents re sults of labosatory analysis of the coal samples taken during test, working parameters of the unit and upgraded electrostatic precipitator system during the tests as well as results of the calculations. The results of the measurements confirm that particulate matter concentration in the flue gas from reconstructed electrostatic precipitators fall down below guaranteed values, thus confirming the effectiveness of the reconstructive operations.
T2  - Termotehnika
T1  - Smanjenje emisije praškastih materija posle rekonstrukcije i modernizacije elektrofilterskih postrojenja na TE „Nikola Tesla B”
VL  - 42
IS  - 1-2
SP  - 73
EP  - 83
DO  - 10.5937/termoteh1601073E
ER  - 
@article{
author = "Erić, Milić and Stefanović, Predrag and Marković, Zoran and Škobalj, Predrag and Cvetinović, Dejan and Jovanović, Rastko and Lazović, Ivan",
year = "2016",
abstract = "U odgovarajuće propise domaćeg zakonodavstva uključeni su zahtevi iz međunarodnog dokumenta, Direktiva 2001/80/EC, koji se odnose na ograničenje emisije praškastih materija iz velikih termoenergetskih postrojenja. Shodno preuzetim obavezama, od 2005. godine započelo se sa rekonstrukcijama i modernizacijama elektrofilterskih postrojenja svih termoblokova u sastavu JP EPS. Na termoelektrani 'Nikola Tesla B' je tokom 2011. godine izvršena rekonstrukcija i modernizacija elektrofilterskog postrojenja bloka B2, dok je rekonstrukcija elektrofilterskog postrojenja bloka B1 obavljena tokom 2012. godine. Cilj obavljenih rekonstrukcija, finansiranih donacijama Evropske Unije, bio je da se emisija praškastih materija u dimnom gasu iz ovih blokova spusti na nivo ispod 50 mg/Nm3, za normalne uslove i pri garantovanim radnim uslovima kotla i elektrofilterskog postrojenja. U radu su prikazani rezultati merenja koncentracija praškastih materija u dimnom gasu iza elektrofiltera, obavljenih u skladu sa zahtevima međunarodnih standarda ISO 9096 i EN 13284-1 nakon rekonstrukcije elektrofilterskih postrojenja termoelektrane TENT B, kao i rezultati ispitivanja obavljenih nakon isteka perioda od godinu dana od završetka rekonstrukcija. Dobijeni rezultati potvrđuju da je izlazna koncentracija praškastih materija ispod garantovane vrednosti, čime je potvrđena uspešnosti izvedenih rekonstruktivnih zahvata., The requirements of the international document Directive 2001/80/EC relating to limitation of the particulate matter emissions from large thermal power plants have been incorporated into relevant regulations of domestic legislation. In accordance with the commitments, since 2005 it was started with reconstruction and modernization of electrostatic precipitator system of all thermal units within the Electric Power Industry of Serbia. The reconstruction and modernization of electrostatic precipitator system of the unit B2 of thermal power plant 'Nikola Tesla B' was done during 2011, while the reconstruction of the electrostatic precipitator system of the unit B1 was conducted in 2012 year. One of the main objectives of performed reconstructions and modernizations, financed by donations of the European Union, was to decrease the emission of particulate matter in the flue gas from these units down to level below 50 mg/Nm3, in normal conditions and under guaranteed operating conditions of the boiler and electrostatic precipitator system. This paper presents results of the measurements of particulate matter concentration performed in accordance with standards ISO 9096 and EN 13284-1, immediately after the reconstruction and shortly before the end of the period of about 1 year after the reconstruction, as a part of control and guarantee investigations of the reconstructed electrostatic precipitators of Thermal Power Plant Nikola Tesla B units. In addition, this paper presents re sults of labosatory analysis of the coal samples taken during test, working parameters of the unit and upgraded electrostatic precipitator system during the tests as well as results of the calculations. The results of the measurements confirm that particulate matter concentration in the flue gas from reconstructed electrostatic precipitators fall down below guaranteed values, thus confirming the effectiveness of the reconstructive operations.",
journal = "Termotehnika",
title = "Smanjenje emisije praškastih materija posle rekonstrukcije i modernizacije elektrofilterskih postrojenja na TE „Nikola Tesla B”",
volume = "42",
number = "1-2",
pages = "73-83",
doi = "10.5937/termoteh1601073E"
}
Erić, M., Stefanović, P., Marković, Z., Škobalj, P., Cvetinović, D., Jovanović, R.,& Lazović, I.. (2016). Smanjenje emisije praškastih materija posle rekonstrukcije i modernizacije elektrofilterskih postrojenja na TE „Nikola Tesla B”. in Termotehnika, 42(1-2), 73-83.
https://doi.org/10.5937/termoteh1601073E
Erić M, Stefanović P, Marković Z, Škobalj P, Cvetinović D, Jovanović R, Lazović I. Smanjenje emisije praškastih materija posle rekonstrukcije i modernizacije elektrofilterskih postrojenja na TE „Nikola Tesla B”. in Termotehnika. 2016;42(1-2):73-83.
doi:10.5937/termoteh1601073E .
Erić, Milić, Stefanović, Predrag, Marković, Zoran, Škobalj, Predrag, Cvetinović, Dejan, Jovanović, Rastko, Lazović, Ivan, "Smanjenje emisije praškastih materija posle rekonstrukcije i modernizacije elektrofilterskih postrojenja na TE „Nikola Tesla B”" in Termotehnika, 42, no. 1-2 (2016):73-83,
https://doi.org/10.5937/termoteh1601073E . .

Pahs Levels in Gas and Particle-Bound Phase in Schools At Different Locations in Serbia

Živković, Marija M.; Jovašević-Stojanović, Milena; Cvetković, Anka; Lazović, Ivan; Tasic, Visa; Stevanović, Žana; Gržetić, Ivan A.

(2015)

TY  - JOUR
AU  - Živković, Marija M.
AU  - Jovašević-Stojanović, Milena
AU  - Cvetković, Anka
AU  - Lazović, Ivan
AU  - Tasic, Visa
AU  - Stevanović, Žana
AU  - Gržetić, Ivan A.
PY  - 2015
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/549
AB  - This study investigated seasonal variation of PAHs and their partition between gas and particulate-bounded phases in indoor and outdoor air in 4 schools In Serbia located at different locations. The sampling campaigns were conducted during one workweek at each school successively. Campaigns were conducted in schools during heating and non-heating seasons in December 2011 and June 2012. Seasonal variations of gas and particle-bounded PAHs concentrations were observed with higher levels during heating season. The highest total PAH values were associated with the gas phase in both sampling periods. The total PAHs concentration at indoor and at the outdoor sites, during heating season, ranged from 88.45 to 447.72 ng/m(3) and 201.69 to 1017.15 ng/m(3), respectively. During non-heating season, the total PAHs concentration ranged from 36.91 to 271.57 ng/m(3) in Indoor environment and 27.00 to 132.32 ng/m(3) in outdoor environment. Most of the I/O ratios were less than 1, which indicated that the indoor PAHs were mostly from outdoor sources. The use of diagnostic ratio showed that traffic emission and coal combustion are the major sources of PAHs. Only the diagnostic ratios for the school located near the industrial area showed significant deviation compared to other schools.
T2  - Chemical Industry and Chemical Engineering Quarterly / CICEQ
T1  - Pahs Levels in Gas and Particle-Bound Phase in Schools At Different Locations in Serbia
VL  - 21
IS  - 1
SP  - 159
EP  - 167
DO  - 10.2298/CICEQ140206016Z
ER  - 
@article{
author = "Živković, Marija M. and Jovašević-Stojanović, Milena and Cvetković, Anka and Lazović, Ivan and Tasic, Visa and Stevanović, Žana and Gržetić, Ivan A.",
year = "2015",
abstract = "This study investigated seasonal variation of PAHs and their partition between gas and particulate-bounded phases in indoor and outdoor air in 4 schools In Serbia located at different locations. The sampling campaigns were conducted during one workweek at each school successively. Campaigns were conducted in schools during heating and non-heating seasons in December 2011 and June 2012. Seasonal variations of gas and particle-bounded PAHs concentrations were observed with higher levels during heating season. The highest total PAH values were associated with the gas phase in both sampling periods. The total PAHs concentration at indoor and at the outdoor sites, during heating season, ranged from 88.45 to 447.72 ng/m(3) and 201.69 to 1017.15 ng/m(3), respectively. During non-heating season, the total PAHs concentration ranged from 36.91 to 271.57 ng/m(3) in Indoor environment and 27.00 to 132.32 ng/m(3) in outdoor environment. Most of the I/O ratios were less than 1, which indicated that the indoor PAHs were mostly from outdoor sources. The use of diagnostic ratio showed that traffic emission and coal combustion are the major sources of PAHs. Only the diagnostic ratios for the school located near the industrial area showed significant deviation compared to other schools.",
journal = "Chemical Industry and Chemical Engineering Quarterly / CICEQ",
title = "Pahs Levels in Gas and Particle-Bound Phase in Schools At Different Locations in Serbia",
volume = "21",
number = "1",
pages = "159-167",
doi = "10.2298/CICEQ140206016Z"
}
Živković, M. M., Jovašević-Stojanović, M., Cvetković, A., Lazović, I., Tasic, V., Stevanović, Ž.,& Gržetić, I. A.. (2015). Pahs Levels in Gas and Particle-Bound Phase in Schools At Different Locations in Serbia. in Chemical Industry and Chemical Engineering Quarterly / CICEQ, 21(1), 159-167.
https://doi.org/10.2298/CICEQ140206016Z
Živković MM, Jovašević-Stojanović M, Cvetković A, Lazović I, Tasic V, Stevanović Ž, Gržetić IA. Pahs Levels in Gas and Particle-Bound Phase in Schools At Different Locations in Serbia. in Chemical Industry and Chemical Engineering Quarterly / CICEQ. 2015;21(1):159-167.
doi:10.2298/CICEQ140206016Z .
Živković, Marija M., Jovašević-Stojanović, Milena, Cvetković, Anka, Lazović, Ivan, Tasic, Visa, Stevanović, Žana, Gržetić, Ivan A., "Pahs Levels in Gas and Particle-Bound Phase in Schools At Different Locations in Serbia" in Chemical Industry and Chemical Engineering Quarterly / CICEQ, 21, no. 1 (2015):159-167,
https://doi.org/10.2298/CICEQ140206016Z . .
12
11
15

Pm and Co2 Variability and Relationship in Different School Environments

Lazović, Ivan; Jovašević-Stojanović, Milena; Živković, Marija M.; Tasic, Visa; Stevanović, Žarko M.

(2015)

TY  - JOUR
AU  - Lazović, Ivan
AU  - Jovašević-Stojanović, Milena
AU  - Živković, Marija M.
AU  - Tasic, Visa
AU  - Stevanović, Žarko M.
PY  - 2015
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/550
AB  - Indoor air quality (IAQ) is very important for children health and well-being, since children are particularly vulnerable and sensitive to the presence of air pollutants. This study was performed in two naturally ventilated schools located in the same municipality. The first school is located in an urban area, at a residential-industrial site, while the other school is situated in a rural area. School buildings were chosen based on their urban environment features. The measurements were carried out in heating and non-heating periods in duration of five consecutive working days. The objective of the study was to analyze IAQ in the classrooms with special emphasis on levels and diurnal variations of particulate matter (PM10 and PM2.5), carbon dioxide (CO2) and nitrogen dioxide (NO2) in occupied and unoccupied school classrooms. In this paper, the CO2 concentrations were measured at both indoor and outdoor environments. Concentrations of CO2 higher than 1000 ppm were regularly detected in the Classrooms during teaching hours. Indoor concentrations of PM10 were not exceeded the guideline, daily average, value of 50 mu g/m(3). Concentrations of PM2.5 exceeded the guideline daily average value of 25 mu g/m(3) in both school during heating period. Concentrations of NO2 did not exceed the guideline value of 200 mu g/m(3). Ventilation rates were calculated and compared with the prescribed limits. In both occupied and unoccupied periods high correlation between CO2 and PM concentrations was determined,
T2  - Chemical Industry and Chemical Engineering Quarterly / CICEQ
T1  - Pm and Co2 Variability and Relationship in Different School Environments
VL  - 21
IS  - 1
SP  - 179
EP  - 187
DO  - 10.2298/CICEQ140212020L
ER  - 
@article{
author = "Lazović, Ivan and Jovašević-Stojanović, Milena and Živković, Marija M. and Tasic, Visa and Stevanović, Žarko M.",
year = "2015",
abstract = "Indoor air quality (IAQ) is very important for children health and well-being, since children are particularly vulnerable and sensitive to the presence of air pollutants. This study was performed in two naturally ventilated schools located in the same municipality. The first school is located in an urban area, at a residential-industrial site, while the other school is situated in a rural area. School buildings were chosen based on their urban environment features. The measurements were carried out in heating and non-heating periods in duration of five consecutive working days. The objective of the study was to analyze IAQ in the classrooms with special emphasis on levels and diurnal variations of particulate matter (PM10 and PM2.5), carbon dioxide (CO2) and nitrogen dioxide (NO2) in occupied and unoccupied school classrooms. In this paper, the CO2 concentrations were measured at both indoor and outdoor environments. Concentrations of CO2 higher than 1000 ppm were regularly detected in the Classrooms during teaching hours. Indoor concentrations of PM10 were not exceeded the guideline, daily average, value of 50 mu g/m(3). Concentrations of PM2.5 exceeded the guideline daily average value of 25 mu g/m(3) in both school during heating period. Concentrations of NO2 did not exceed the guideline value of 200 mu g/m(3). Ventilation rates were calculated and compared with the prescribed limits. In both occupied and unoccupied periods high correlation between CO2 and PM concentrations was determined,",
journal = "Chemical Industry and Chemical Engineering Quarterly / CICEQ",
title = "Pm and Co2 Variability and Relationship in Different School Environments",
volume = "21",
number = "1",
pages = "179-187",
doi = "10.2298/CICEQ140212020L"
}
Lazović, I., Jovašević-Stojanović, M., Živković, M. M., Tasic, V.,& Stevanović, Ž. M.. (2015). Pm and Co2 Variability and Relationship in Different School Environments. in Chemical Industry and Chemical Engineering Quarterly / CICEQ, 21(1), 179-187.
https://doi.org/10.2298/CICEQ140212020L
Lazović I, Jovašević-Stojanović M, Živković MM, Tasic V, Stevanović ŽM. Pm and Co2 Variability and Relationship in Different School Environments. in Chemical Industry and Chemical Engineering Quarterly / CICEQ. 2015;21(1):179-187.
doi:10.2298/CICEQ140212020L .
Lazović, Ivan, Jovašević-Stojanović, Milena, Živković, Marija M., Tasic, Visa, Stevanović, Žarko M., "Pm and Co2 Variability and Relationship in Different School Environments" in Chemical Industry and Chemical Engineering Quarterly / CICEQ, 21, no. 1 (2015):179-187,
https://doi.org/10.2298/CICEQ140212020L . .
15
8
11