Vasović, Nikola

Link to this page

Authority KeyName Variants
ec9e92d5-e23a-4278-aef6-315862cec913
  • Vasović, Nikola (4)
Projects
No records found.

Author's Bibliography

An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts

Vasović, Nikola; Duane, Russell; Ristić, Goran; Stanković, Srboljub

(Niš : Faculty of Electronic Engineering, 2023)

TY  - CONF
AU  - Vasović, Nikola
AU  - Duane, Russell
AU  - Ristić, Goran
AU  - Stanković, Srboljub
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12122
AB  - An improved RADFET based module dosemeter has been developed by Varadis (a spin out company of Tyndall National Institute in Cork, Ireland) with serial number RM-VT01-A. The module is based on commercially available, commercial-off-the-shelf (COTS) parts and represents an updated version of its predecessor RM-VT01 with an upper dose limit of 10Gy (1 kRad) also based on COTS parts. The RM-VT01-A module was tested to a total dose of 1kGy (100 kRad) in Co60 field at Vinča Institute of Nuclear Sciences, Belgrade, Serbia. The improved module circuit was specifically designed to address the challenge of withstanding 1 kGy (100 kRad) received dose. The primary goal of this poster is to present the improvements in the circuit design and working principle. For this purpose, eleven modules were tested, 8 powered and 3 unpowered during irradiation. The module electronics accommodates both irradiation “sense” and readout “single-current-point” mode, outputting the RADFET threshold voltage (VT) as a dosimetric information, directly proportional to the absorbed dose. The output voltage of the module was measured with a simple benchtop voltmeter to demonstrate module operation simplicity and easy system integrability. The experimental data results showed excellent agreement with the dosimetry system used at the Vinca irradiation facility, and calibration data of the VT01 RadFET part.
PB  - Niš : Faculty of Electronic Engineering
C3  - ELICSIR Project Symposium : Book of abstracts
T1  - An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts
SP  - 49
EP  - 49
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12122
ER  - 
@conference{
author = "Vasović, Nikola and Duane, Russell and Ristić, Goran and Stanković, Srboljub",
year = "2023",
abstract = "An improved RADFET based module dosemeter has been developed by Varadis (a spin out company of Tyndall National Institute in Cork, Ireland) with serial number RM-VT01-A. The module is based on commercially available, commercial-off-the-shelf (COTS) parts and represents an updated version of its predecessor RM-VT01 with an upper dose limit of 10Gy (1 kRad) also based on COTS parts. The RM-VT01-A module was tested to a total dose of 1kGy (100 kRad) in Co60 field at Vinča Institute of Nuclear Sciences, Belgrade, Serbia. The improved module circuit was specifically designed to address the challenge of withstanding 1 kGy (100 kRad) received dose. The primary goal of this poster is to present the improvements in the circuit design and working principle. For this purpose, eleven modules were tested, 8 powered and 3 unpowered during irradiation. The module electronics accommodates both irradiation “sense” and readout “single-current-point” mode, outputting the RADFET threshold voltage (VT) as a dosimetric information, directly proportional to the absorbed dose. The output voltage of the module was measured with a simple benchtop voltmeter to demonstrate module operation simplicity and easy system integrability. The experimental data results showed excellent agreement with the dosimetry system used at the Vinca irradiation facility, and calibration data of the VT01 RadFET part.",
publisher = "Niš : Faculty of Electronic Engineering",
journal = "ELICSIR Project Symposium : Book of abstracts",
title = "An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts",
pages = "49-49",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12122"
}
Vasović, N., Duane, R., Ristić, G.,& Stanković, S.. (2023). An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts. in ELICSIR Project Symposium : Book of abstracts
Niš : Faculty of Electronic Engineering., 49-49.
https://hdl.handle.net/21.15107/rcub_vinar_12122
Vasović N, Duane R, Ristić G, Stanković S. An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts. in ELICSIR Project Symposium : Book of abstracts. 2023;:49-49.
https://hdl.handle.net/21.15107/rcub_vinar_12122 .
Vasović, Nikola, Duane, Russell, Ristić, Goran, Stanković, Srboljub, "An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts" in ELICSIR Project Symposium : Book of abstracts (2023):49-49,
https://hdl.handle.net/21.15107/rcub_vinar_12122 .

A Metal Oxide Semiconductor ionizing radiation detector architecture with increased voltage sensitivity

Duane, Russell; Vasović, Nikola; White, Mary; Blake, Alan; Marie McGarrigle, Anne; Stanković, Srboljub; Jakšić, Aleksandar

(RAD Centre, Niš, Serbia, 2022)

TY  - CONF
AU  - Duane, Russell
AU  - Vasović, Nikola
AU  - White, Mary
AU  - Blake, Alan
AU  - Marie McGarrigle, Anne
AU  - Stanković, Srboljub
AU  - Jakšić, Aleksandar
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11116
AB  - A Metal Oxide Semiconductor (MOS) ionizing radiation detector architecture which senses trapped charge in the dielectric due to incident ionizing radiation is presented. The detector architecture increases output voltage signal as a function of trapped charge in the sensing dielectric in comparison with state of the art MOSFET (RADFET) technology. Numerical simulations were employed to help develop the device concept. It is shown that an improved voltage sensitivity is possible due to a reduction in the sensing capacitance which, unlike RADFET technology, is decoupled from the dielectric capacitance. An initial prototype of the detector has been fabricated in the silicon fabrication facility of Tyndall National Institute and irradiation experiments have been performed which confirm the improved voltage sensitivity versus commercial RADFET detectors. It is envisaged that further sensitivity increases may be possible by integrating dielectrics other than silicon dioxide.
PB  - RAD Centre, Niš, Serbia
C3  - RAD 2022 : 10th Jubilee International Conference on Radiation in Various Fields of Research : book of abstracts; June 13-17; Herceg Novi, Montenegro
T1  - A Metal Oxide Semiconductor ionizing radiation detector architecture with increased voltage sensitivity
SP  - 109
DO  - 10.21175/rad.spr.abstr.book.2022.26.8
ER  - 
@conference{
author = "Duane, Russell and Vasović, Nikola and White, Mary and Blake, Alan and Marie McGarrigle, Anne and Stanković, Srboljub and Jakšić, Aleksandar",
year = "2022",
abstract = "A Metal Oxide Semiconductor (MOS) ionizing radiation detector architecture which senses trapped charge in the dielectric due to incident ionizing radiation is presented. The detector architecture increases output voltage signal as a function of trapped charge in the sensing dielectric in comparison with state of the art MOSFET (RADFET) technology. Numerical simulations were employed to help develop the device concept. It is shown that an improved voltage sensitivity is possible due to a reduction in the sensing capacitance which, unlike RADFET technology, is decoupled from the dielectric capacitance. An initial prototype of the detector has been fabricated in the silicon fabrication facility of Tyndall National Institute and irradiation experiments have been performed which confirm the improved voltage sensitivity versus commercial RADFET detectors. It is envisaged that further sensitivity increases may be possible by integrating dielectrics other than silicon dioxide.",
publisher = "RAD Centre, Niš, Serbia",
journal = "RAD 2022 : 10th Jubilee International Conference on Radiation in Various Fields of Research : book of abstracts; June 13-17; Herceg Novi, Montenegro",
title = "A Metal Oxide Semiconductor ionizing radiation detector architecture with increased voltage sensitivity",
pages = "109",
doi = "10.21175/rad.spr.abstr.book.2022.26.8"
}
Duane, R., Vasović, N., White, M., Blake, A., Marie McGarrigle, A., Stanković, S.,& Jakšić, A.. (2022). A Metal Oxide Semiconductor ionizing radiation detector architecture with increased voltage sensitivity. in RAD 2022 : 10th Jubilee International Conference on Radiation in Various Fields of Research : book of abstracts; June 13-17; Herceg Novi, Montenegro
RAD Centre, Niš, Serbia., 109.
https://doi.org/10.21175/rad.spr.abstr.book.2022.26.8
Duane R, Vasović N, White M, Blake A, Marie McGarrigle A, Stanković S, Jakšić A. A Metal Oxide Semiconductor ionizing radiation detector architecture with increased voltage sensitivity. in RAD 2022 : 10th Jubilee International Conference on Radiation in Various Fields of Research : book of abstracts; June 13-17; Herceg Novi, Montenegro. 2022;:109.
doi:10.21175/rad.spr.abstr.book.2022.26.8 .
Duane, Russell, Vasović, Nikola, White, Mary, Blake, Alan, Marie McGarrigle, Anne, Stanković, Srboljub, Jakšić, Aleksandar, "A Metal Oxide Semiconductor ionizing radiation detector architecture with increased voltage sensitivity" in RAD 2022 : 10th Jubilee International Conference on Radiation in Various Fields of Research : book of abstracts; June 13-17; Herceg Novi, Montenegro (2022):109,
https://doi.org/10.21175/rad.spr.abstr.book.2022.26.8 . .

Radiation Response of Two Types of Commercial RADFETs

Jakšić, Aleksandar; Vasović, Nikola; Duane, Russell; Stanković, Srboljub; Martinez-Garcia, Maria Sofia; Palma, Alberto; Ristić, Goran

(RAD Association, Niš, Serbia, 2017)

TY  - CONF
AU  - Jakšić, Aleksandar
AU  - Vasović, Nikola
AU  - Duane, Russell
AU  - Stanković, Srboljub
AU  - Martinez-Garcia, Maria Sofia
AU  - Palma, Alberto
AU  - Ristić, Goran
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11196
PB  - RAD Association, Niš, Serbia
C3  - RAD 2017 : 5th International Conference on Radiation in Various Fields of Research : book of abstracts; June 12-16, 2017; Budva, Montenegro
T1  - Radiation Response of Two Types of Commercial RADFETs
SP  - 179
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11196
ER  - 
@conference{
author = "Jakšić, Aleksandar and Vasović, Nikola and Duane, Russell and Stanković, Srboljub and Martinez-Garcia, Maria Sofia and Palma, Alberto and Ristić, Goran",
year = "2017",
publisher = "RAD Association, Niš, Serbia",
journal = "RAD 2017 : 5th International Conference on Radiation in Various Fields of Research : book of abstracts; June 12-16, 2017; Budva, Montenegro",
title = "Radiation Response of Two Types of Commercial RADFETs",
pages = "179",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11196"
}
Jakšić, A., Vasović, N., Duane, R., Stanković, S., Martinez-Garcia, M. S., Palma, A.,& Ristić, G.. (2017). Radiation Response of Two Types of Commercial RADFETs. in RAD 2017 : 5th International Conference on Radiation in Various Fields of Research : book of abstracts; June 12-16, 2017; Budva, Montenegro
RAD Association, Niš, Serbia., 179.
https://hdl.handle.net/21.15107/rcub_vinar_11196
Jakšić A, Vasović N, Duane R, Stanković S, Martinez-Garcia MS, Palma A, Ristić G. Radiation Response of Two Types of Commercial RADFETs. in RAD 2017 : 5th International Conference on Radiation in Various Fields of Research : book of abstracts; June 12-16, 2017; Budva, Montenegro. 2017;:179.
https://hdl.handle.net/21.15107/rcub_vinar_11196 .
Jakšić, Aleksandar, Vasović, Nikola, Duane, Russell, Stanković, Srboljub, Martinez-Garcia, Maria Sofia, Palma, Alberto, Ristić, Goran, "Radiation Response of Two Types of Commercial RADFETs" in RAD 2017 : 5th International Conference on Radiation in Various Fields of Research : book of abstracts; June 12-16, 2017; Budva, Montenegro (2017):179,
https://hdl.handle.net/21.15107/rcub_vinar_11196 .

Razlika između odziva RADFET u statičkom i dinamičkom on-line mernom sistemu prilikom izlaganja gama zračenju Co60

Stanković, Srboljub; Jakšić, Aleksandar; Vasović, Nikola; Lončar, Boris B.; Kržanović, Nikola; Živanović, Miloš Z.

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2017)

TY  - CONF
AU  - Stanković, Srboljub
AU  - Jakšić, Aleksandar
AU  - Vasović, Nikola
AU  - Lončar, Boris B.
AU  - Kržanović, Nikola
AU  - Živanović, Miloš Z.
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8332
UR  - https://plus.sr.cobiss.net/opac7/bib/245691404
UR  - http://dzz.org.rs/wp-content/uploads/2013/06/Zbornik_XXIX_Simpozijum_DZZ_SCG_Srebrno_jezero_2.pdf
AB  - U ovom radu su sprovedena eksperimentalna istraživanja odziva ESAPMOS4 RADFET
komponenti u polju gama zračenja 60Co kada su inkorporirane u dva različita merna
sistema, u statičkom i dinamičkom on-line mernom sistemu. Značaj istraživanja se
ogleda u uspostavljanju metoda kojim se ostvaruje eksperimentalna karakterizacija
RADFET strukture u poljima jonizujućeg zračenja s obzirom da se koristi on-line merna
tehnika određivanja zavisnosti napona praga RADFET od promene apsorbovane doze
zračenja u dinamičkom režimu rada digitalnog mernog sistema. To znači da se
kontinualno sprovodi registrovanje vrednosti električne veličine kojom se prati odziv
MOSFET-a u tačno zadatim vremenskim intervalima dok traje ozračivanje komponente,
što ranije nije bio slučaj u statičkom režimu merenja promene napona praga. Razlika
između izmerenih odziva za dva različita sistema merenja je bila u granicama
eksperimentalne merne nesigurnosti od 2% do 5% .
AB  - In this paper, experimental responses to ESAPMOS4 RADFET components in the field
of gamma radiation 60Co were performed when incorporated into two different
measurement systems, in a static and dynamic on-line measurement systems. The
significance of the research is reflected in the establishment of methods for achieving
the experimental characterization of the RADFET structure in ionizing radiation fields
since the use of an on-line measuring technique for determining the dependence of the
RADFET threshold voltage on changing the absorbed dose of radiation in the dynamic
regime of the digital measuring system is used. This means that continuously the
registration of an electrical quantity value to monitor the response of the MOSFET at
precisely defined time intervals while the component is irradiated, which was not the
case before in the static measurement mode of change the threshold voltage. The
difference between the measured responses for two different measurement systems was
within the experimental measurement uncertainty of 2% to 5%.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 29. симпозијум ДЗЗСЦГ : зборник радова
T1  - Razlika između odziva RADFET u statičkom i dinamičkom on-line mernom sistemu prilikom izlaganja gama zračenju Co60
T1  - Difference between RADFET response in static and dynamic on-line measurement systems during exposed to gamma radiation of Co60
SP  - 579
EP  - 586
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8332
ER  - 
@conference{
author = "Stanković, Srboljub and Jakšić, Aleksandar and Vasović, Nikola and Lončar, Boris B. and Kržanović, Nikola and Živanović, Miloš Z.",
year = "2017",
abstract = "U ovom radu su sprovedena eksperimentalna istraživanja odziva ESAPMOS4 RADFET
komponenti u polju gama zračenja 60Co kada su inkorporirane u dva različita merna
sistema, u statičkom i dinamičkom on-line mernom sistemu. Značaj istraživanja se
ogleda u uspostavljanju metoda kojim se ostvaruje eksperimentalna karakterizacija
RADFET strukture u poljima jonizujućeg zračenja s obzirom da se koristi on-line merna
tehnika određivanja zavisnosti napona praga RADFET od promene apsorbovane doze
zračenja u dinamičkom režimu rada digitalnog mernog sistema. To znači da se
kontinualno sprovodi registrovanje vrednosti električne veličine kojom se prati odziv
MOSFET-a u tačno zadatim vremenskim intervalima dok traje ozračivanje komponente,
što ranije nije bio slučaj u statičkom režimu merenja promene napona praga. Razlika
između izmerenih odziva za dva različita sistema merenja je bila u granicama
eksperimentalne merne nesigurnosti od 2% do 5% ., In this paper, experimental responses to ESAPMOS4 RADFET components in the field
of gamma radiation 60Co were performed when incorporated into two different
measurement systems, in a static and dynamic on-line measurement systems. The
significance of the research is reflected in the establishment of methods for achieving
the experimental characterization of the RADFET structure in ionizing radiation fields
since the use of an on-line measuring technique for determining the dependence of the
RADFET threshold voltage on changing the absorbed dose of radiation in the dynamic
regime of the digital measuring system is used. This means that continuously the
registration of an electrical quantity value to monitor the response of the MOSFET at
precisely defined time intervals while the component is irradiated, which was not the
case before in the static measurement mode of change the threshold voltage. The
difference between the measured responses for two different measurement systems was
within the experimental measurement uncertainty of 2% to 5%.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "29. симпозијум ДЗЗСЦГ : зборник радова",
title = "Razlika između odziva RADFET u statičkom i dinamičkom on-line mernom sistemu prilikom izlaganja gama zračenju Co60, Difference between RADFET response in static and dynamic on-line measurement systems during exposed to gamma radiation of Co60",
pages = "579-586",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8332"
}
Stanković, S., Jakšić, A., Vasović, N., Lončar, B. B., Kržanović, N.,& Živanović, M. Z.. (2017). Razlika između odziva RADFET u statičkom i dinamičkom on-line mernom sistemu prilikom izlaganja gama zračenju Co60. in 29. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 579-586.
https://hdl.handle.net/21.15107/rcub_vinar_8332
Stanković S, Jakšić A, Vasović N, Lončar BB, Kržanović N, Živanović MZ. Razlika između odziva RADFET u statičkom i dinamičkom on-line mernom sistemu prilikom izlaganja gama zračenju Co60. in 29. симпозијум ДЗЗСЦГ : зборник радова. 2017;:579-586.
https://hdl.handle.net/21.15107/rcub_vinar_8332 .
Stanković, Srboljub, Jakšić, Aleksandar, Vasović, Nikola, Lončar, Boris B., Kržanović, Nikola, Živanović, Miloš Z., "Razlika između odziva RADFET u statičkom i dinamičkom on-line mernom sistemu prilikom izlaganja gama zračenju Co60" in 29. симпозијум ДЗЗСЦГ : зборник радова (2017):579-586,
https://hdl.handle.net/21.15107/rcub_vinar_8332 .