Perazić, Luka

Link to this page

Authority KeyName Variants
15ba3acc-30e4-47c7-a93f-c2174a68720c
  • Perazić, Luka (6)
Projects

Author's Bibliography

Comparison of experimental and simulated responses of TL and OSL dosimeters in poly-energetic and multi-directional photon radiation fields

Apostolakopoulos, Filip Haralambos; Kržanović, Nikola; Božović, Predrag; Stanković, Koviljka; Perazić, Luka

(2021)

TY  - JOUR
AU  - Apostolakopoulos, Filip Haralambos
AU  - Kržanović, Nikola
AU  - Božović, Predrag
AU  - Stanković, Koviljka
AU  - Perazić, Luka
PY  - 2021
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10275
AB  - The aim of this paper is to examine the energy and angular responses of thermoluminescent (LiF:Mg,Ti and LiF:Mg,Cu,P) and optically stimulated luminescent (Al2O3:C) dosimeters with experimental measurements and Monte Carlo simulations. Nine radiation qualities, with mean energies ranging from 33 keV to 1.25 MeV, and five angles of incidence, between 0° and 80°, were used to conduct this analysis. The IEC 62387:2020 international radiation protection standard was used as the dosimeter response measure of quality. The experimental and simulated data exhibit that the dosimeter responses meet the standard's criteria, with certain exceptions on lower energies.
T2  - Nuclear Technology and Radiation Protection
T1  - Comparison of experimental and simulated responses of TL and OSL dosimeters in poly-energetic and multi-directional photon radiation fields
VL  - 36
IS  - 4
SP  - 329
EP  - 337
DO  - 10.2298/NTRP2104329A
ER  - 
@article{
author = "Apostolakopoulos, Filip Haralambos and Kržanović, Nikola and Božović, Predrag and Stanković, Koviljka and Perazić, Luka",
year = "2021",
abstract = "The aim of this paper is to examine the energy and angular responses of thermoluminescent (LiF:Mg,Ti and LiF:Mg,Cu,P) and optically stimulated luminescent (Al2O3:C) dosimeters with experimental measurements and Monte Carlo simulations. Nine radiation qualities, with mean energies ranging from 33 keV to 1.25 MeV, and five angles of incidence, between 0° and 80°, were used to conduct this analysis. The IEC 62387:2020 international radiation protection standard was used as the dosimeter response measure of quality. The experimental and simulated data exhibit that the dosimeter responses meet the standard's criteria, with certain exceptions on lower energies.",
journal = "Nuclear Technology and Radiation Protection",
title = "Comparison of experimental and simulated responses of TL and OSL dosimeters in poly-energetic and multi-directional photon radiation fields",
volume = "36",
number = "4",
pages = "329-337",
doi = "10.2298/NTRP2104329A"
}
Apostolakopoulos, F. H., Kržanović, N., Božović, P., Stanković, K.,& Perazić, L.. (2021). Comparison of experimental and simulated responses of TL and OSL dosimeters in poly-energetic and multi-directional photon radiation fields. in Nuclear Technology and Radiation Protection, 36(4), 329-337.
https://doi.org/10.2298/NTRP2104329A
Apostolakopoulos FH, Kržanović N, Božović P, Stanković K, Perazić L. Comparison of experimental and simulated responses of TL and OSL dosimeters in poly-energetic and multi-directional photon radiation fields. in Nuclear Technology and Radiation Protection. 2021;36(4):329-337.
doi:10.2298/NTRP2104329A .
Apostolakopoulos, Filip Haralambos, Kržanović, Nikola, Božović, Predrag, Stanković, Koviljka, Perazić, Luka, "Comparison of experimental and simulated responses of TL and OSL dosimeters in poly-energetic and multi-directional photon radiation fields" in Nuclear Technology and Radiation Protection, 36, no. 4 (2021):329-337,
https://doi.org/10.2298/NTRP2104329A . .
2
1

Response of TL and OSL passive personal dosimetry systems in poly-energetic and multi-directional photon radiation fields

Apostolakopoulos, Filip Haralambos; Kržanović, Nikola; Stanković, Koviljka; Perazić, Luka

(2019)

TY  - JOUR
AU  - Apostolakopoulos, Filip Haralambos
AU  - Kržanović, Nikola
AU  - Stanković, Koviljka
AU  - Perazić, Luka
PY  - 2019
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8347
AB  - The aim of this paper is to examine the energy and angular responses of thermoluminescent dosimeters containing either MTS-N (LiF:Mg,Ti) or MCP-N (LiF:Mg,Cu,P) detector materials, and of the InLight optically stimulated luminescent dosimeters containing Al2O3:C detectors. Ten radiation qualities, with mean energies ranging from 24 keV to 1.25 MeV, and five angles of incidence, between 0° and 80°, were used for this purpose. The dosimeter response measure of quality were the IEC 62387 requirements. The experimental results show that the MTS-N-based and the InLight dosimeters performed in line with the standard's criteria. On the other hand, the MCP-N-based dosimeters exhibited a pronounced under-response around the energy of 120 keV, which resulted in deviations from the standard's conditions for both the energy and angular responses. © 2019 Elsevier Ltd
T2  - Applied Radiation and Isotopes
T1  - Response of TL and OSL passive personal dosimetry systems in poly-energetic and multi-directional photon radiation fields
VL  - 151
SP  - 235
EP  - 241
DO  - 10.1016/j.apradiso.2019.06.023
ER  - 
@article{
author = "Apostolakopoulos, Filip Haralambos and Kržanović, Nikola and Stanković, Koviljka and Perazić, Luka",
year = "2019",
abstract = "The aim of this paper is to examine the energy and angular responses of thermoluminescent dosimeters containing either MTS-N (LiF:Mg,Ti) or MCP-N (LiF:Mg,Cu,P) detector materials, and of the InLight optically stimulated luminescent dosimeters containing Al2O3:C detectors. Ten radiation qualities, with mean energies ranging from 24 keV to 1.25 MeV, and five angles of incidence, between 0° and 80°, were used for this purpose. The dosimeter response measure of quality were the IEC 62387 requirements. The experimental results show that the MTS-N-based and the InLight dosimeters performed in line with the standard's criteria. On the other hand, the MCP-N-based dosimeters exhibited a pronounced under-response around the energy of 120 keV, which resulted in deviations from the standard's conditions for both the energy and angular responses. © 2019 Elsevier Ltd",
journal = "Applied Radiation and Isotopes",
title = "Response of TL and OSL passive personal dosimetry systems in poly-energetic and multi-directional photon radiation fields",
volume = "151",
pages = "235-241",
doi = "10.1016/j.apradiso.2019.06.023"
}
Apostolakopoulos, F. H., Kržanović, N., Stanković, K.,& Perazić, L.. (2019). Response of TL and OSL passive personal dosimetry systems in poly-energetic and multi-directional photon radiation fields. in Applied Radiation and Isotopes, 151, 235-241.
https://doi.org/10.1016/j.apradiso.2019.06.023
Apostolakopoulos FH, Kržanović N, Stanković K, Perazić L. Response of TL and OSL passive personal dosimetry systems in poly-energetic and multi-directional photon radiation fields. in Applied Radiation and Isotopes. 2019;151:235-241.
doi:10.1016/j.apradiso.2019.06.023 .
Apostolakopoulos, Filip Haralambos, Kržanović, Nikola, Stanković, Koviljka, Perazić, Luka, "Response of TL and OSL passive personal dosimetry systems in poly-energetic and multi-directional photon radiation fields" in Applied Radiation and Isotopes, 151 (2019):235-241,
https://doi.org/10.1016/j.apradiso.2019.06.023 . .
10
3
10

Low-energy X-ray Angular Response of Optically Stimulated Luminescent Dosimeters

Kržanović, Nikola; Haralambos Apostolakopoulos, Filip; Perazić, Luka; Stanković, Koviljka

(Belgrade : ETRAN Society, 2018)

TY  - CONF
AU  - Kržanović, Nikola
AU  - Haralambos Apostolakopoulos, Filip
AU  - Perazić, Luka
AU  - Stanković, Koviljka
PY  - 2018
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11917
AB  - Following the requirements of radiation protection international standards, passive dosimetry systems are type tested, which includes the angular dependence. As it represents one of the most important dosimeter characteristics, the angular dependence of commercially available optically stimulated luminescent dosimeters has been examined in this paper. The empirically determined air kerma to the personal dose equivalent conversion coefficients decrease as the angle of incidence increases. It was anticipated that the dosimeter response would show a similar behavior. This expectation has been confirmed for all the used angles of incidence and energies of the primary X-ray beam, except for the 80° angle of incidence and the 33 keV and 48 keV mean photon energies, where an increase in the angular response has been observed.
PB  - Belgrade : ETRAN Society
C3  - IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book
T1  - Low-energy X-ray Angular Response of Optically Stimulated Luminescent Dosimeters
SP  - 1005
EP  - 1007
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11917
ER  - 
@conference{
author = "Kržanović, Nikola and Haralambos Apostolakopoulos, Filip and Perazić, Luka and Stanković, Koviljka",
year = "2018",
abstract = "Following the requirements of radiation protection international standards, passive dosimetry systems are type tested, which includes the angular dependence. As it represents one of the most important dosimeter characteristics, the angular dependence of commercially available optically stimulated luminescent dosimeters has been examined in this paper. The empirically determined air kerma to the personal dose equivalent conversion coefficients decrease as the angle of incidence increases. It was anticipated that the dosimeter response would show a similar behavior. This expectation has been confirmed for all the used angles of incidence and energies of the primary X-ray beam, except for the 80° angle of incidence and the 33 keV and 48 keV mean photon energies, where an increase in the angular response has been observed.",
publisher = "Belgrade : ETRAN Society",
journal = "IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book",
title = "Low-energy X-ray Angular Response of Optically Stimulated Luminescent Dosimeters",
pages = "1005-1007",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11917"
}
Kržanović, N., Haralambos Apostolakopoulos, F., Perazić, L.,& Stanković, K.. (2018). Low-energy X-ray Angular Response of Optically Stimulated Luminescent Dosimeters. in IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book
Belgrade : ETRAN Society., 1005-1007.
https://hdl.handle.net/21.15107/rcub_vinar_11917
Kržanović N, Haralambos Apostolakopoulos F, Perazić L, Stanković K. Low-energy X-ray Angular Response of Optically Stimulated Luminescent Dosimeters. in IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book. 2018;:1005-1007.
https://hdl.handle.net/21.15107/rcub_vinar_11917 .
Kržanović, Nikola, Haralambos Apostolakopoulos, Filip, Perazić, Luka, Stanković, Koviljka, "Low-energy X-ray Angular Response of Optically Stimulated Luminescent Dosimeters" in IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book (2018):1005-1007,
https://hdl.handle.net/21.15107/rcub_vinar_11917 .

Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters

Haralambos Apostolakopoulos, Filip; Kržanović, Nikola; Perazić, Luka; Stanković, Koviljka

(Belgrade : ETRAN Society, 2017)

TY  - CONF
AU  - Haralambos Apostolakopoulos, Filip
AU  - Kržanović, Nikola
AU  - Perazić, Luka
AU  - Stanković, Koviljka
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11914
AB  - Determination of the angular dependence of thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters is of great importance for their application in poly-energetic multidirectional photon radiation fields. In order to determine the angular dependence of the dosimeter responses for different photon energies, the dosimeters were mounted on an ISO water slab phantom, irradiated in two narrow beam X-ray qualities (N-40 and N-80) and in one gamma ray quality (S-Cs), defined in IAEA SRS 16. The angles of incidence ranged from 0° to 60°, with an increment of 20°. Two types of TL dosimeters were used: MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) and one type of OSL dosimeters, InLight (Al2O3:C). The two types of TL dosimeters have shown a similar deviation from their 0° responses for all the used radiation qualities, while the OSL dosimeters have shown a greater deviation from the reference values for the gamma radiation quality.
PB  - Belgrade : ETRAN Society
C3  - IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book
T1  - Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11914
ER  - 
@conference{
author = "Haralambos Apostolakopoulos, Filip and Kržanović, Nikola and Perazić, Luka and Stanković, Koviljka",
year = "2017",
abstract = "Determination of the angular dependence of thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters is of great importance for their application in poly-energetic multidirectional photon radiation fields. In order to determine the angular dependence of the dosimeter responses for different photon energies, the dosimeters were mounted on an ISO water slab phantom, irradiated in two narrow beam X-ray qualities (N-40 and N-80) and in one gamma ray quality (S-Cs), defined in IAEA SRS 16. The angles of incidence ranged from 0° to 60°, with an increment of 20°. Two types of TL dosimeters were used: MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) and one type of OSL dosimeters, InLight (Al2O3:C). The two types of TL dosimeters have shown a similar deviation from their 0° responses for all the used radiation qualities, while the OSL dosimeters have shown a greater deviation from the reference values for the gamma radiation quality.",
publisher = "Belgrade : ETRAN Society",
journal = "IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book",
title = "Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11914"
}
Haralambos Apostolakopoulos, F., Kržanović, N., Perazić, L.,& Stanković, K.. (2017). Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters. in IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book
Belgrade : ETRAN Society..
https://hdl.handle.net/21.15107/rcub_vinar_11914
Haralambos Apostolakopoulos F, Kržanović N, Perazić L, Stanković K. Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters. in IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book. 2017;.
https://hdl.handle.net/21.15107/rcub_vinar_11914 .
Haralambos Apostolakopoulos, Filip, Kržanović, Nikola, Perazić, Luka, Stanković, Koviljka, "Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters" in IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book (2017),
https://hdl.handle.net/21.15107/rcub_vinar_11914 .

Radiološka karakterizacija industrijskog objekta - nekadašnjeg pogona za proizvodnju fosforne kiseline "Elixir Zorka - mineralna đubriva doo Šabac"

Zdjelarević, Nevena; Stanković, Koviljka; Perazić, Luka; Lekić, Marija; Lazarević, Nataša; Jevremović, Milutin

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2017)

TY  - CONF
AU  - Zdjelarević, Nevena
AU  - Stanković, Koviljka
AU  - Perazić, Luka
AU  - Lekić, Marija
AU  - Lazarević, Nataša
AU  - Jevremović, Milutin
PY  - 2017
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8292
UR  - https://plus.sr.cobiss.net/opac7/bib/245691404
UR  - http://dzz.org.rs/wp-content/uploads/2013/06/Zbornik_XXIX_Simpozijum_DZZ_SCG_Srebrno_jezero_2.pdf
AB  - U procesu dobijanja fosforne kiseline, tehnološkim postupkom povećava se prisustvo
prirodne radioaktivnosti, stoga nekadašnji pogon za proizvodnju fosforne kiseline
predstavlja takozvano „istorijsko zagađenje”, i kao takav predstavlja potencijalnu
opasnost u smislu nepotrebnog izlaganja zračenju.
U okviru poslova dekontaminacije starog pogona izvršena je radiološka karakterizacija
postrojenja pre, tokom i nakon postupka dekontaminacije, koja je podrazumevala
uklanjanja samo nevezane kontaminacije sa svih površina i predmeta koji se nalaze u
postrojenju. Radiološka karakterizacije predstvalja osnov za određivanje adekvatnog
načina dekontaminacije, kao i za proveru njene efikasnosti. U radu su prikazani
rezultati nivoa radioaktivne kontaminacije površina i merenja jačine ambijentalnog
ekvivalenta doze gama zračenja na 15 cm od podloge.
AB  - In the process of the production of phosphoric acid, a technological process increases
the presence of natural radioactivity, therefore, the former plant for the production of
phosphoric acid, presents the so-called "historical pollution", and as such represents a
potential threat in terms of unnecessary exposure to radiation.
In the framework of the decontamination of the old plan, radiological characterization
of the plant was carried out before, during and after the decontamination process,
which involved the removal of a non-fixed contamination on all surfaces and objects
that have been found in the plant. Radiological characterization present the good base
for determining of adequate ways of decontamination, as well as to verify its
effectiveness. The paper presents the results of the level of radioactive contamination of
the surface and measurements of the intensity of ambient dose equivalent at 15 cm from
the surfaces.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 29. симпозијум ДЗЗСЦГ : зборник радова
T1  - Radiološka karakterizacija industrijskog objekta - nekadašnjeg pogona za proizvodnju fosforne kiseline "Elixir Zorka - mineralna đubriva doo Šabac"
T1  - Radiological survey of industrial building - a former facility for the production of phosphoric acid "Elixir Zorka - mineralna đubriva doo Šabac"
SP  - 307
EP  - 314
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8292
ER  - 
@conference{
author = "Zdjelarević, Nevena and Stanković, Koviljka and Perazić, Luka and Lekić, Marija and Lazarević, Nataša and Jevremović, Milutin",
year = "2017",
abstract = "U procesu dobijanja fosforne kiseline, tehnološkim postupkom povećava se prisustvo
prirodne radioaktivnosti, stoga nekadašnji pogon za proizvodnju fosforne kiseline
predstavlja takozvano „istorijsko zagađenje”, i kao takav predstavlja potencijalnu
opasnost u smislu nepotrebnog izlaganja zračenju.
U okviru poslova dekontaminacije starog pogona izvršena je radiološka karakterizacija
postrojenja pre, tokom i nakon postupka dekontaminacije, koja je podrazumevala
uklanjanja samo nevezane kontaminacije sa svih površina i predmeta koji se nalaze u
postrojenju. Radiološka karakterizacije predstvalja osnov za određivanje adekvatnog
načina dekontaminacije, kao i za proveru njene efikasnosti. U radu su prikazani
rezultati nivoa radioaktivne kontaminacije površina i merenja jačine ambijentalnog
ekvivalenta doze gama zračenja na 15 cm od podloge., In the process of the production of phosphoric acid, a technological process increases
the presence of natural radioactivity, therefore, the former plant for the production of
phosphoric acid, presents the so-called "historical pollution", and as such represents a
potential threat in terms of unnecessary exposure to radiation.
In the framework of the decontamination of the old plan, radiological characterization
of the plant was carried out before, during and after the decontamination process,
which involved the removal of a non-fixed contamination on all surfaces and objects
that have been found in the plant. Radiological characterization present the good base
for determining of adequate ways of decontamination, as well as to verify its
effectiveness. The paper presents the results of the level of radioactive contamination of
the surface and measurements of the intensity of ambient dose equivalent at 15 cm from
the surfaces.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "29. симпозијум ДЗЗСЦГ : зборник радова",
title = "Radiološka karakterizacija industrijskog objekta - nekadašnjeg pogona za proizvodnju fosforne kiseline "Elixir Zorka - mineralna đubriva doo Šabac", Radiological survey of industrial building - a former facility for the production of phosphoric acid "Elixir Zorka - mineralna đubriva doo Šabac"",
pages = "307-314",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8292"
}
Zdjelarević, N., Stanković, K., Perazić, L., Lekić, M., Lazarević, N.,& Jevremović, M.. (2017). Radiološka karakterizacija industrijskog objekta - nekadašnjeg pogona za proizvodnju fosforne kiseline "Elixir Zorka - mineralna đubriva doo Šabac". in 29. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 307-314.
https://hdl.handle.net/21.15107/rcub_vinar_8292
Zdjelarević N, Stanković K, Perazić L, Lekić M, Lazarević N, Jevremović M. Radiološka karakterizacija industrijskog objekta - nekadašnjeg pogona za proizvodnju fosforne kiseline "Elixir Zorka - mineralna đubriva doo Šabac". in 29. симпозијум ДЗЗСЦГ : зборник радова. 2017;:307-314.
https://hdl.handle.net/21.15107/rcub_vinar_8292 .
Zdjelarević, Nevena, Stanković, Koviljka, Perazić, Luka, Lekić, Marija, Lazarević, Nataša, Jevremović, Milutin, "Radiološka karakterizacija industrijskog objekta - nekadašnjeg pogona za proizvodnju fosforne kiseline "Elixir Zorka - mineralna đubriva doo Šabac"" in 29. симпозијум ДЗЗСЦГ : зборник радова (2017):307-314,
https://hdl.handle.net/21.15107/rcub_vinar_8292 .

Comparison of the Energy and Angular Responses of Thermoluminescent and Electronic Personal Dosimeters

Haralambos Apostolakopoulos, Filip; Kržanović, Nikola; Perazić, Luka; Živanović, Miloš; Stanković, Koviljka

(Belgrade : ETRAN Society, 2016)

TY  - CONF
AU  - Haralambos Apostolakopoulos, Filip
AU  - Kržanović, Nikola
AU  - Perazić, Luka
AU  - Živanović, Miloš
AU  - Stanković, Koviljka
PY  - 2016
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11915
AB  - Determination of the response of thermoluminescent and electronic personal dosimeters as a function of photon energy and angle of incidence has a crucial impact on their application in poly-energetic multidirectional photon radiation fields. In the experimental part of this paper, in order to determine the energy dependence of the dosimeter responses, the dosimeters were mounted on an ISO slab phantom, irradiated in X and gamma ray fields, defined in the IAEA SRS 16, within the energy range of 33 keV - 1,25 MeV. Tested dosimeters have not shown an adequate response in the low photon energies relative to their Cs-137 responses, while in the middle and high energy photon ranges they performed well and have shown a deviation relative to their Cs-137 responses up to ±20%. In order to determine the angular dependence of the dosimeters the N-200 narrow beam radiation quality has been used. The angles of incidence for which the dosimeters were tested range from 0° to 80°, with an increment of 20°. Most of the dosimeters have behaved as expected, except for certain dosimeters due to their significant increase in response caused by the influence of the scattered radiation.
PB  - Belgrade : ETRAN Society
C3  - IcETRAN 2016 : 3rd International Conference on Electrical, Electronic and Computing Engineering; Proceedings book
T1  - Comparison of the Energy and Angular Responses of Thermoluminescent and Electronic Personal Dosimeters
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11915
ER  - 
@conference{
author = "Haralambos Apostolakopoulos, Filip and Kržanović, Nikola and Perazić, Luka and Živanović, Miloš and Stanković, Koviljka",
year = "2016",
abstract = "Determination of the response of thermoluminescent and electronic personal dosimeters as a function of photon energy and angle of incidence has a crucial impact on their application in poly-energetic multidirectional photon radiation fields. In the experimental part of this paper, in order to determine the energy dependence of the dosimeter responses, the dosimeters were mounted on an ISO slab phantom, irradiated in X and gamma ray fields, defined in the IAEA SRS 16, within the energy range of 33 keV - 1,25 MeV. Tested dosimeters have not shown an adequate response in the low photon energies relative to their Cs-137 responses, while in the middle and high energy photon ranges they performed well and have shown a deviation relative to their Cs-137 responses up to ±20%. In order to determine the angular dependence of the dosimeters the N-200 narrow beam radiation quality has been used. The angles of incidence for which the dosimeters were tested range from 0° to 80°, with an increment of 20°. Most of the dosimeters have behaved as expected, except for certain dosimeters due to their significant increase in response caused by the influence of the scattered radiation.",
publisher = "Belgrade : ETRAN Society",
journal = "IcETRAN 2016 : 3rd International Conference on Electrical, Electronic and Computing Engineering; Proceedings book",
title = "Comparison of the Energy and Angular Responses of Thermoluminescent and Electronic Personal Dosimeters",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11915"
}
Haralambos Apostolakopoulos, F., Kržanović, N., Perazić, L., Živanović, M.,& Stanković, K.. (2016). Comparison of the Energy and Angular Responses of Thermoluminescent and Electronic Personal Dosimeters. in IcETRAN 2016 : 3rd International Conference on Electrical, Electronic and Computing Engineering; Proceedings book
Belgrade : ETRAN Society..
https://hdl.handle.net/21.15107/rcub_vinar_11915
Haralambos Apostolakopoulos F, Kržanović N, Perazić L, Živanović M, Stanković K. Comparison of the Energy and Angular Responses of Thermoluminescent and Electronic Personal Dosimeters. in IcETRAN 2016 : 3rd International Conference on Electrical, Electronic and Computing Engineering; Proceedings book. 2016;.
https://hdl.handle.net/21.15107/rcub_vinar_11915 .
Haralambos Apostolakopoulos, Filip, Kržanović, Nikola, Perazić, Luka, Živanović, Miloš, Stanković, Koviljka, "Comparison of the Energy and Angular Responses of Thermoluminescent and Electronic Personal Dosimeters" in IcETRAN 2016 : 3rd International Conference on Electrical, Electronic and Computing Engineering; Proceedings book (2016),
https://hdl.handle.net/21.15107/rcub_vinar_11915 .