Vujović, Velibor V.

Link to this page

Authority KeyName Variants
fea68198-15ea-46dc-8c9d-1cbb5917ba98
  • Vujović, Velibor V. (6)
Projects

Author's Bibliography

Upgrading of the CAPRICE type ECR ion source

Efremov, Andrey; Bogomolov, Sergey; Bekhterev, Vladimir; Dobrosavljević, Aleksandar S.; Vujović, Velibor V.; Nešković, Nebojša B.; Trajić, Ivan

(2018)

TY  - CONF
AU  - Efremov, Andrey
AU  - Bogomolov, Sergey
AU  - Bekhterev, Vladimir
AU  - Dobrosavljević, Aleksandar S.
AU  - Vujović, Velibor V.
AU  - Nešković, Nebojša B.
AU  - Trajić, Ivan
PY  - 2018
UR  - http://aip.scitation.org/doi/abs/10.1063/1.5053291
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7900
AB  - The CAPRICE-type ECR ion source mVINIS has been upgraded by increasing its magnetic field to improve a plasma confinement and thereby enhance the source performance. This modification made it also possible to increase the internal diameter of the plasma chamber and to replace the coaxial microwave input by a waveguide. Some major subsystems such as: the vacuum system, the microwave system, the gas inlet system, the solid substance inlet system, and the control system have been also refurbished. All these improvements have resulted in a substantial increase of ion beam currents, especially in the case of high charge states, with the operation of the ion source proven to be stable and reproducible. This modification can be applied to other CAPRICE-type ion sources. © 2018 Author(s).
C3  - AIP Conference Proceedings
T1  - Upgrading of the CAPRICE type ECR ion source
VL  - 2011
SP  - 040017
DO  - 10.1063/1.5053291
ER  - 
@conference{
author = "Efremov, Andrey and Bogomolov, Sergey and Bekhterev, Vladimir and Dobrosavljević, Aleksandar S. and Vujović, Velibor V. and Nešković, Nebojša B. and Trajić, Ivan",
year = "2018",
abstract = "The CAPRICE-type ECR ion source mVINIS has been upgraded by increasing its magnetic field to improve a plasma confinement and thereby enhance the source performance. This modification made it also possible to increase the internal diameter of the plasma chamber and to replace the coaxial microwave input by a waveguide. Some major subsystems such as: the vacuum system, the microwave system, the gas inlet system, the solid substance inlet system, and the control system have been also refurbished. All these improvements have resulted in a substantial increase of ion beam currents, especially in the case of high charge states, with the operation of the ion source proven to be stable and reproducible. This modification can be applied to other CAPRICE-type ion sources. © 2018 Author(s).",
journal = "AIP Conference Proceedings",
title = "Upgrading of the CAPRICE type ECR ion source",
volume = "2011",
pages = "040017",
doi = "10.1063/1.5053291"
}
Efremov, A., Bogomolov, S., Bekhterev, V., Dobrosavljević, A. S., Vujović, V. V., Nešković, N. B.,& Trajić, I.. (2018). Upgrading of the CAPRICE type ECR ion source. in AIP Conference Proceedings, 2011, 040017.
https://doi.org/10.1063/1.5053291
Efremov A, Bogomolov S, Bekhterev V, Dobrosavljević AS, Vujović VV, Nešković NB, Trajić I. Upgrading of the CAPRICE type ECR ion source. in AIP Conference Proceedings. 2018;2011:040017.
doi:10.1063/1.5053291 .
Efremov, Andrey, Bogomolov, Sergey, Bekhterev, Vladimir, Dobrosavljević, Aleksandar S., Vujović, Velibor V., Nešković, Nebojša B., Trajić, Ivan, "Upgrading of the CAPRICE type ECR ion source" in AIP Conference Proceedings, 2011 (2018):040017,
https://doi.org/10.1063/1.5053291 . .
2

Determining the Composition of High Temperature Combustion Products of Fossil Fuel Based on Variational Principles and Geometric Programming

Vujović, Velibor V.

(2011)

TY  - JOUR
AU  - Vujović, Velibor V.
PY  - 2011
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/4294
AB  - This paper presents the algorithm and results of a computer program for calculation of complex equilibrium composition for the high temperature fossil fuel combustion products. The method of determining the composition of high temperatures combustion products at the temperatures appearing in the open cycle MHD power generation is given. The determination of combustion product composition is based on minimization of the Gibbs free energy. The number of equations to be solved is reduced by using variational principles and a method of geometric programming and is equal to the sum of the numbers of elements and phases. A short description of the computer program for the calculation of the composition and an example of the results are also given.
T2  - Thermal Science
T1  - Determining the Composition of High Temperature Combustion Products of Fossil Fuel Based on Variational Principles and Geometric Programming
VL  - 15
IS  - 1
SP  - 125
EP  - 134
DO  - 10.2298/TSCI100928007V
ER  - 
@article{
author = "Vujović, Velibor V.",
year = "2011",
abstract = "This paper presents the algorithm and results of a computer program for calculation of complex equilibrium composition for the high temperature fossil fuel combustion products. The method of determining the composition of high temperatures combustion products at the temperatures appearing in the open cycle MHD power generation is given. The determination of combustion product composition is based on minimization of the Gibbs free energy. The number of equations to be solved is reduced by using variational principles and a method of geometric programming and is equal to the sum of the numbers of elements and phases. A short description of the computer program for the calculation of the composition and an example of the results are also given.",
journal = "Thermal Science",
title = "Determining the Composition of High Temperature Combustion Products of Fossil Fuel Based on Variational Principles and Geometric Programming",
volume = "15",
number = "1",
pages = "125-134",
doi = "10.2298/TSCI100928007V"
}
Vujović, V. V.. (2011). Determining the Composition of High Temperature Combustion Products of Fossil Fuel Based on Variational Principles and Geometric Programming. in Thermal Science, 15(1), 125-134.
https://doi.org/10.2298/TSCI100928007V
Vujović VV. Determining the Composition of High Temperature Combustion Products of Fossil Fuel Based on Variational Principles and Geometric Programming. in Thermal Science. 2011;15(1):125-134.
doi:10.2298/TSCI100928007V .
Vujović, Velibor V., "Determining the Composition of High Temperature Combustion Products of Fossil Fuel Based on Variational Principles and Geometric Programming" in Thermal Science, 15, no. 1 (2011):125-134,
https://doi.org/10.2298/TSCI100928007V . .

A channel for modification of materials with post-accelerated or decelerated multiply charged ion beams

Dobrosavljević, Aleksandar S.; Nešković, Nebojša B.; Beličev, Petar; Čomor, Jožef J.; Vujović, Velibor V.; Balvanović, Roman V.; Ristić-Đurović, Jasna L.

(2008)

TY  - JOUR
AU  - Dobrosavljević, Aleksandar S.
AU  - Nešković, Nebojša B.
AU  - Beličev, Petar
AU  - Čomor, Jožef J.
AU  - Vujović, Velibor V.
AU  - Balvanović, Roman V.
AU  - Ristić-Đurović, Jasna L.
PY  - 2008
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/3600
AB  - t present, heavy ion beams from the electron cyclotron resonance (ECR) ion source in the Laboratory of Physics of the Vinca Institute of Nuclear Sciences, Belgrade, Serbia, are employed in a channel for surface modification of materials. The source and channel were commissioned in 1998, and have been used since that time by a number of user groups from the Vinca Institute and other scientific and educational institutions in Serbia. However, since the maximum extraction voltage of the source is +25 kV, sometimes the extracted beams do not have sufficiently high energies for such applications. Therefore, in order to solve this problem, we have decided to construct a new channel, to be used for deeper modification of materials. The beams obtained from the source will be post-accelerated by biasing the target to be irradiated to the negative potentials of down to - 100 W For example, we shall be able to bombard the target with the (132)Xe(24+) beam of the energy of up to 3 MeV, instead of up to 600 keV, in the case without the biasing system. An additional possibility will be to bias the target to the positive potentials of up to +25 kV and thus decelerate the beams extracted from the source down to the energies of about 1 keV. Consequently, one will be able to modify materials with the beams in a wide energy range, from similar to 1 to similar to 3 MeV, which is rarely met at similar experimental set-ups. It must be noted that changing the post-accelerated or decelerated beam energy in the new channel will be performed simply by adjusting the power supply of the biasing system, without any adjustments of the source and of the transport elements between the source and the interaction chamber. (C) 2008 Elsevier B.V. All rights reserved.
T2  - Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
T1  - A channel for modification of materials with post-accelerated or decelerated multiply charged ion beams
VL  - 597
IS  - 2-3
SP  - 136
EP  - 141
DO  - 10.1016/j.nima.2008.08.148
ER  - 
@article{
author = "Dobrosavljević, Aleksandar S. and Nešković, Nebojša B. and Beličev, Petar and Čomor, Jožef J. and Vujović, Velibor V. and Balvanović, Roman V. and Ristić-Đurović, Jasna L.",
year = "2008",
abstract = "t present, heavy ion beams from the electron cyclotron resonance (ECR) ion source in the Laboratory of Physics of the Vinca Institute of Nuclear Sciences, Belgrade, Serbia, are employed in a channel for surface modification of materials. The source and channel were commissioned in 1998, and have been used since that time by a number of user groups from the Vinca Institute and other scientific and educational institutions in Serbia. However, since the maximum extraction voltage of the source is +25 kV, sometimes the extracted beams do not have sufficiently high energies for such applications. Therefore, in order to solve this problem, we have decided to construct a new channel, to be used for deeper modification of materials. The beams obtained from the source will be post-accelerated by biasing the target to be irradiated to the negative potentials of down to - 100 W For example, we shall be able to bombard the target with the (132)Xe(24+) beam of the energy of up to 3 MeV, instead of up to 600 keV, in the case without the biasing system. An additional possibility will be to bias the target to the positive potentials of up to +25 kV and thus decelerate the beams extracted from the source down to the energies of about 1 keV. Consequently, one will be able to modify materials with the beams in a wide energy range, from similar to 1 to similar to 3 MeV, which is rarely met at similar experimental set-ups. It must be noted that changing the post-accelerated or decelerated beam energy in the new channel will be performed simply by adjusting the power supply of the biasing system, without any adjustments of the source and of the transport elements between the source and the interaction chamber. (C) 2008 Elsevier B.V. All rights reserved.",
journal = "Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment",
title = "A channel for modification of materials with post-accelerated or decelerated multiply charged ion beams",
volume = "597",
number = "2-3",
pages = "136-141",
doi = "10.1016/j.nima.2008.08.148"
}
Dobrosavljević, A. S., Nešković, N. B., Beličev, P., Čomor, J. J., Vujović, V. V., Balvanović, R. V.,& Ristić-Đurović, J. L.. (2008). A channel for modification of materials with post-accelerated or decelerated multiply charged ion beams. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 597(2-3), 136-141.
https://doi.org/10.1016/j.nima.2008.08.148
Dobrosavljević AS, Nešković NB, Beličev P, Čomor JJ, Vujović VV, Balvanović RV, Ristić-Đurović JL. A channel for modification of materials with post-accelerated or decelerated multiply charged ion beams. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. 2008;597(2-3):136-141.
doi:10.1016/j.nima.2008.08.148 .
Dobrosavljević, Aleksandar S., Nešković, Nebojša B., Beličev, Petar, Čomor, Jožef J., Vujović, Velibor V., Balvanović, Roman V., Ristić-Đurović, Jasna L., "A channel for modification of materials with post-accelerated or decelerated multiply charged ion beams" in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 597, no. 2-3 (2008):136-141,
https://doi.org/10.1016/j.nima.2008.08.148 . .
3
3
5

Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation

Cirkovic, Sasa; Ristić-Đurović, Jasna L.; Ihic, Andjelija Z.; Vujović, Velibor V.; Negkovic, Nebojsa A.

(2008)

TY  - JOUR
AU  - Cirkovic, Sasa
AU  - Ristić-Đurović, Jasna L.
AU  - Ihic, Andjelija Z.
AU  - Vujović, Velibor V.
AU  - Negkovic, Nebojsa A.
PY  - 2008
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/3622
AB  - Accurate magnetic fields are needed for defining the operation of a multipurpose cyclotron as well as for designing other parts of the machine, as an input parameter. The quality of an isochronous magnetic field is evaluated by the closeness of the obtained ion gyration frequency to its required value. The commonly used method of isochronous field calculation for sector focused cyclotrons was Gordons procedure. The incorporation of the gyration frequency criterion in isochronous field calculation has grown with the increase of the computer speed. We suggest a highly accurate method for the isochronous magnetic field calculation based on the gyration frequency adjustment.
T2  - IEEE Transactions on Nuclear Science
T1  - Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation
VL  - 55
IS  - 6
SP  - 3531
EP  - 3538
DO  - 10.1109/TNS.2008.2005498
ER  - 
@article{
author = "Cirkovic, Sasa and Ristić-Đurović, Jasna L. and Ihic, Andjelija Z. and Vujović, Velibor V. and Negkovic, Nebojsa A.",
year = "2008",
abstract = "Accurate magnetic fields are needed for defining the operation of a multipurpose cyclotron as well as for designing other parts of the machine, as an input parameter. The quality of an isochronous magnetic field is evaluated by the closeness of the obtained ion gyration frequency to its required value. The commonly used method of isochronous field calculation for sector focused cyclotrons was Gordons procedure. The incorporation of the gyration frequency criterion in isochronous field calculation has grown with the increase of the computer speed. We suggest a highly accurate method for the isochronous magnetic field calculation based on the gyration frequency adjustment.",
journal = "IEEE Transactions on Nuclear Science",
title = "Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation",
volume = "55",
number = "6",
pages = "3531-3538",
doi = "10.1109/TNS.2008.2005498"
}
Cirkovic, S., Ristić-Đurović, J. L., Ihic, A. Z., Vujović, V. V.,& Negkovic, N. A.. (2008). Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation. in IEEE Transactions on Nuclear Science, 55(6), 3531-3538.
https://doi.org/10.1109/TNS.2008.2005498
Cirkovic S, Ristić-Đurović JL, Ihic AZ, Vujović VV, Negkovic NA. Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation. in IEEE Transactions on Nuclear Science. 2008;55(6):3531-3538.
doi:10.1109/TNS.2008.2005498 .
Cirkovic, Sasa, Ristić-Đurović, Jasna L., Ihic, Andjelija Z., Vujović, Velibor V., Negkovic, Nebojsa A., "Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation" in IEEE Transactions on Nuclear Science, 55, no. 6 (2008):3531-3538,
https://doi.org/10.1109/TNS.2008.2005498 . .
10
10
10

Status report of the VINCY cyclotron

Nešković, Nebojša B.; Ristić-Đurović, Jasna L.; Vorojtsov, SB; Beličev, Petar; Ivanenko, IA; Cirkovic, S; Vorozhtsov, AS; Bojović, Boško; Dobrosavljević, Aleksandar S.; Vujović, Velibor V.; Čomor, Jožef J.; Pajović, Snežana B.

(2003)

TY  - JOUR
AU  - Nešković, Nebojša B.
AU  - Ristić-Đurović, Jasna L.
AU  - Vorojtsov, SB
AU  - Beličev, Petar
AU  - Ivanenko, IA
AU  - Cirkovic, S
AU  - Vorozhtsov, AS
AU  - Bojović, Boško
AU  - Dobrosavljević, Aleksandar S.
AU  - Vujović, Velibor V.
AU  - Čomor, Jožef J.
AU  - Pajović, Snežana B.
PY  - 2003
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/6381
AB  - The VINCY Cyclotron is the main part of the TESLA Accelerator Installation. The diameter of the pole of this machine is 2000 mm. Its bending constant is 145 MeV while its focusing constant is 75 MeV. The radiofrequency system of the machine consists of two lambda/4-resonators with the eigenfrequency in the range from 17 to 31 MHz. Ions coming from a heavy ion source or a light ion source will be injected into the machine axially. They will be introduced into its median plane by a spiral inflector. Heavy ions accelerated in the machine will be extracted from it by a foil stripping system or by an electrostatic deflection system. Light ions will be extracted from it by the foil stripping system. The first programs of use of the VINCY Cyclotron are related to routine and experimental production of radioisotopes and radiopharmaceuticals, and to biomedical research with ion beams. The first beam extracted from the machine will be the proton beam of the energy of 22 MeV obtained from the H-2(+) beam extracted from the light ion source. This beam will be used first for production of radioisotope F-18 and radiopharmaceutical (18)FDG, to be employed for positron emission tomography.
T2  - Nukleonika
T1  - Status report of the VINCY cyclotron
VL  - 48
SP  - S135
EP  - S139
UR  - https://hdl.handle.net/21.15107/rcub_vinar_6381
ER  - 
@article{
author = "Nešković, Nebojša B. and Ristić-Đurović, Jasna L. and Vorojtsov, SB and Beličev, Petar and Ivanenko, IA and Cirkovic, S and Vorozhtsov, AS and Bojović, Boško and Dobrosavljević, Aleksandar S. and Vujović, Velibor V. and Čomor, Jožef J. and Pajović, Snežana B.",
year = "2003",
abstract = "The VINCY Cyclotron is the main part of the TESLA Accelerator Installation. The diameter of the pole of this machine is 2000 mm. Its bending constant is 145 MeV while its focusing constant is 75 MeV. The radiofrequency system of the machine consists of two lambda/4-resonators with the eigenfrequency in the range from 17 to 31 MHz. Ions coming from a heavy ion source or a light ion source will be injected into the machine axially. They will be introduced into its median plane by a spiral inflector. Heavy ions accelerated in the machine will be extracted from it by a foil stripping system or by an electrostatic deflection system. Light ions will be extracted from it by the foil stripping system. The first programs of use of the VINCY Cyclotron are related to routine and experimental production of radioisotopes and radiopharmaceuticals, and to biomedical research with ion beams. The first beam extracted from the machine will be the proton beam of the energy of 22 MeV obtained from the H-2(+) beam extracted from the light ion source. This beam will be used first for production of radioisotope F-18 and radiopharmaceutical (18)FDG, to be employed for positron emission tomography.",
journal = "Nukleonika",
title = "Status report of the VINCY cyclotron",
volume = "48",
pages = "S135-S139",
url = "https://hdl.handle.net/21.15107/rcub_vinar_6381"
}
Nešković, N. B., Ristić-Đurović, J. L., Vorojtsov, S., Beličev, P., Ivanenko, I., Cirkovic, S., Vorozhtsov, A., Bojović, B., Dobrosavljević, A. S., Vujović, V. V., Čomor, J. J.,& Pajović, S. B.. (2003). Status report of the VINCY cyclotron. in Nukleonika, 48, S135-S139.
https://hdl.handle.net/21.15107/rcub_vinar_6381
Nešković NB, Ristić-Đurović JL, Vorojtsov S, Beličev P, Ivanenko I, Cirkovic S, Vorozhtsov A, Bojović B, Dobrosavljević AS, Vujović VV, Čomor JJ, Pajović SB. Status report of the VINCY cyclotron. in Nukleonika. 2003;48:S135-S139.
https://hdl.handle.net/21.15107/rcub_vinar_6381 .
Nešković, Nebojša B., Ristić-Đurović, Jasna L., Vorojtsov, SB, Beličev, Petar, Ivanenko, IA, Cirkovic, S, Vorozhtsov, AS, Bojović, Boško, Dobrosavljević, Aleksandar S., Vujović, Velibor V., Čomor, Jožef J., Pajović, Snežana B., "Status report of the VINCY cyclotron" in Nukleonika, 48 (2003):S135-S139,
https://hdl.handle.net/21.15107/rcub_vinar_6381 .
17

Magnetic field simulation in the central region of the VINCY Cyclotron

Vorojtsov, SB; Vorozhtsov, AS; Nešković, Nebojša B.; Ristić-Đurović, Jasna L.; Cirkovic, S; Vujović, Velibor V.

(2003)

TY  - JOUR
AU  - Vorojtsov, SB
AU  - Vorozhtsov, AS
AU  - Nešković, Nebojša B.
AU  - Ristić-Đurović, Jasna L.
AU  - Cirkovic, S
AU  - Vujović, Velibor V.
PY  - 2003
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/6380
AB  - The VINCY Cyclotron is under construction at the Vinca Institute of Nuclear Sciences, Laboratory of Physics, Belgrade, Serbia and Montenegro. One of the most difficult problems to solve is the magnetic field shaping in the central region of the machine in a wide range of field levels. The latest measurements showed a very large magnetic field depression in the central region. The following shimming elements are used for the field shaping in the central region: a central plug and a spacer ring between the sectors and the median pole plate. These elements should both release enough vertical space for the inflector and the RF electrodes and produce a field bump in the very center of the machine. Concerning this region, one has to mention the following facts: sectors are absent or very reduced, and the small gap between the sectors restricts remarkably the possibilities of producing a field bump. Therefore, the design of these elements is the most critical one. Optimization of the central plug gap affects both the vertical sparking probability and the beam dynamics at higher harmonic modes. The redesign of the magnetic structure of the central region relied solely on the detailed 3-dimensional calculations to speed up the experimental shimming procedure. The desired calculated magnetic field shapes, which include the influence of the plug, have been produced and confirmed by the particle tracing for the 3-field levels. The final tailoring of the field map will be performed by the measurements at the full-size magnet.
T2  - Nukleonika
T1  - Magnetic field simulation in the central region of the VINCY Cyclotron
VL  - 48
SP  - S39
EP  - S44
UR  - https://hdl.handle.net/21.15107/rcub_vinar_6380
ER  - 
@article{
author = "Vorojtsov, SB and Vorozhtsov, AS and Nešković, Nebojša B. and Ristić-Đurović, Jasna L. and Cirkovic, S and Vujović, Velibor V.",
year = "2003",
abstract = "The VINCY Cyclotron is under construction at the Vinca Institute of Nuclear Sciences, Laboratory of Physics, Belgrade, Serbia and Montenegro. One of the most difficult problems to solve is the magnetic field shaping in the central region of the machine in a wide range of field levels. The latest measurements showed a very large magnetic field depression in the central region. The following shimming elements are used for the field shaping in the central region: a central plug and a spacer ring between the sectors and the median pole plate. These elements should both release enough vertical space for the inflector and the RF electrodes and produce a field bump in the very center of the machine. Concerning this region, one has to mention the following facts: sectors are absent or very reduced, and the small gap between the sectors restricts remarkably the possibilities of producing a field bump. Therefore, the design of these elements is the most critical one. Optimization of the central plug gap affects both the vertical sparking probability and the beam dynamics at higher harmonic modes. The redesign of the magnetic structure of the central region relied solely on the detailed 3-dimensional calculations to speed up the experimental shimming procedure. The desired calculated magnetic field shapes, which include the influence of the plug, have been produced and confirmed by the particle tracing for the 3-field levels. The final tailoring of the field map will be performed by the measurements at the full-size magnet.",
journal = "Nukleonika",
title = "Magnetic field simulation in the central region of the VINCY Cyclotron",
volume = "48",
pages = "S39-S44",
url = "https://hdl.handle.net/21.15107/rcub_vinar_6380"
}
Vorojtsov, S., Vorozhtsov, A., Nešković, N. B., Ristić-Đurović, J. L., Cirkovic, S.,& Vujović, V. V.. (2003). Magnetic field simulation in the central region of the VINCY Cyclotron. in Nukleonika, 48, S39-S44.
https://hdl.handle.net/21.15107/rcub_vinar_6380
Vorojtsov S, Vorozhtsov A, Nešković NB, Ristić-Đurović JL, Cirkovic S, Vujović VV. Magnetic field simulation in the central region of the VINCY Cyclotron. in Nukleonika. 2003;48:S39-S44.
https://hdl.handle.net/21.15107/rcub_vinar_6380 .
Vorojtsov, SB, Vorozhtsov, AS, Nešković, Nebojša B., Ristić-Đurović, Jasna L., Cirkovic, S, Vujović, Velibor V., "Magnetic field simulation in the central region of the VINCY Cyclotron" in Nukleonika, 48 (2003):S39-S44,
https://hdl.handle.net/21.15107/rcub_vinar_6380 .
2