@conference{
author = "Lončar, Boris and Kartalović, N. and Stanković, Srboljub and Vujisić, M. and Osmokrović, Predrag",
year = "2007",
abstract = "Cilj ovog rada je da se ispita uticaj gama i X zračenja na brzinu odziva komercijalnih CITEL i SIEMENS gasnih odvodnika prenapona. Pokazano je da oba tipa zračenja dovode do promene impulsne karakteristike odvodnika.. Dobijeni rezultati pokazuju da su u polju gama zračenja otporniji odvodnici firme CITEL, a u polju X zračenja SIEMENS odvodnici., The aim of this paper is to examine the influence of γ and X radiation to response time of some commercial gas filled surge arresters. We found that both radiations have significant influence on gas filled surge arresters pulse characteristic. The obtained results show that the optimal solution in gamma radiation field was CITEL components, while in X radiation field was better to use SIEMENS components.",
publisher = "Beograd : Institut za nuklearne nauke "Vinča" : Društvo za zaštitu od zračenja Srbije i Crne Gore",
journal = "24. simpozijum DZZSCG : zbornik radova",
title = "Uticaj gama i X zračenja na impulsnu karakteristiku nekih komercijalnih gasnih odvodnika prenapona, The influence of gamma and X radiation on pulse characteristic of some commercial gas filled surge arresters",
pages = "363-366",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12263"
}