Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2

Holme, O.; Adžić, Petar; Di Calafiori, D.; Ćirković, Predrag; Dissertori, G.; Djambazov, L.; Jovanović, Dragana J.; Lustermann, W.; Zelepoukine, S.

(2016)

TY  - JOUR
AU  - Holme, O.
AU  - Adžić, Petar
AU  - Di Calafiori, D.
AU  - Ćirković, Predrag
AU  - Dissertori, G.
AU  - Djambazov, L.
AU  - Jovanović, Dragana J.
AU  - Lustermann, W.
AU  - Zelepoukine, S.
PY  - 2016
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7096
AB  - The Detector Control System of the CMS Electromagnetic Calorimeter has undergone significant improvements during the first LHC Long Shutdown. Based on the experience acquired during the first period of physics data taking of the LHC, several hardware projects were carried out to improve data accuracy, to minimise the impact of failures and to extend remote control possibilities in order to accelerate recovery from problematic situations. This paper outlines the hardware of the detector control and safety systems and explains in detail the requirements, design and commissioning of the new hardware projects.
T2  - Journal of Instrumentation
T1  - Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2
VL  - 11
DO  - 10.1088/1748-0221/11/01/C01020
ER  - 
@article{
author = "Holme, O. and Adžić, Petar and Di Calafiori, D. and Ćirković, Predrag and Dissertori, G. and Djambazov, L. and Jovanović, Dragana J. and Lustermann, W. and Zelepoukine, S.",
year = "2016",
abstract = "The Detector Control System of the CMS Electromagnetic Calorimeter has undergone significant improvements during the first LHC Long Shutdown. Based on the experience acquired during the first period of physics data taking of the LHC, several hardware projects were carried out to improve data accuracy, to minimise the impact of failures and to extend remote control possibilities in order to accelerate recovery from problematic situations. This paper outlines the hardware of the detector control and safety systems and explains in detail the requirements, design and commissioning of the new hardware projects.",
journal = "Journal of Instrumentation",
title = "Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2",
volume = "11",
doi = "10.1088/1748-0221/11/01/C01020"
}
Holme, O., Adžić, P., Di Calafiori, D., Ćirković, P., Dissertori, G., Djambazov, L., Jovanović, D. J., Lustermann, W.,& Zelepoukine, S.. (2016). Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2. in Journal of Instrumentation, 11.
https://doi.org/10.1088/1748-0221/11/01/C01020
Holme O, Adžić P, Di Calafiori D, Ćirković P, Dissertori G, Djambazov L, Jovanović DJ, Lustermann W, Zelepoukine S. Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2. in Journal of Instrumentation. 2016;11.
doi:10.1088/1748-0221/11/01/C01020 .
Holme, O., Adžić, Petar, Di Calafiori, D., Ćirković, Predrag, Dissertori, G., Djambazov, L., Jovanović, Dragana J., Lustermann, W., Zelepoukine, S., "Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2" in Journal of Instrumentation, 11 (2016),
https://doi.org/10.1088/1748-0221/11/01/C01020 . .
1
1
1

The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System

Holme, O.; Adžić, Petar; Di Calafiori, D.; Dissertori, G.; Djambazov, L.; Jovanović, Dragana J.; Lustermann, W.; Zelepoukine, S.

(2014)

TY  - CONF
AU  - Holme, O.
AU  - Adžić, Petar
AU  - Di Calafiori, D.
AU  - Dissertori, G.
AU  - Djambazov, L.
AU  - Jovanović, Dragana J.
AU  - Lustermann, W.
AU  - Zelepoukine, S.
PY  - 2014
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7037
AB  - The Electromagnetic Calorimeter (ECAL) is one of the sub-detectors of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN. The Detector Control System (DCS) that has been developed and implemented for the CMS ECAL was deployed in accordance with the LHC schedule and has been supporting the CMS data-taking since LHC physics runs started in 2009. During these years, the control system has been regularly adapted according to operational experience and new requirements, always respecting the constraints imposed on significant changes to a running system. Several hardware and software upgrades and system extensions were therefore deferred to the first LHC Long Shutdown (LS 1). This paper presents the main architectural differences between the system that supported the CMS ECAL during its first years and the new design for the coming physics runs after LS 1. Details on the upgrade planning, including the certification methods performed in the CMS ECAL DCS laboratory facilities, reports on the implementation progress and the expectations for the post-LS 1 system are highlighted.
C3  - Journal of Physics: Conference Series
T1  - The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System
VL  - 513
DO  - 10.1088/1742-6596/513/1/012013
ER  - 
@conference{
author = "Holme, O. and Adžić, Petar and Di Calafiori, D. and Dissertori, G. and Djambazov, L. and Jovanović, Dragana J. and Lustermann, W. and Zelepoukine, S.",
year = "2014",
abstract = "The Electromagnetic Calorimeter (ECAL) is one of the sub-detectors of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN. The Detector Control System (DCS) that has been developed and implemented for the CMS ECAL was deployed in accordance with the LHC schedule and has been supporting the CMS data-taking since LHC physics runs started in 2009. During these years, the control system has been regularly adapted according to operational experience and new requirements, always respecting the constraints imposed on significant changes to a running system. Several hardware and software upgrades and system extensions were therefore deferred to the first LHC Long Shutdown (LS 1). This paper presents the main architectural differences between the system that supported the CMS ECAL during its first years and the new design for the coming physics runs after LS 1. Details on the upgrade planning, including the certification methods performed in the CMS ECAL DCS laboratory facilities, reports on the implementation progress and the expectations for the post-LS 1 system are highlighted.",
journal = "Journal of Physics: Conference Series",
title = "The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System",
volume = "513",
doi = "10.1088/1742-6596/513/1/012013"
}
Holme, O., Adžić, P., Di Calafiori, D., Dissertori, G., Djambazov, L., Jovanović, D. J., Lustermann, W.,& Zelepoukine, S.. (2014). The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System. in Journal of Physics: Conference Series, 513.
https://doi.org/10.1088/1742-6596/513/1/012013
Holme O, Adžić P, Di Calafiori D, Dissertori G, Djambazov L, Jovanović DJ, Lustermann W, Zelepoukine S. The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System. in Journal of Physics: Conference Series. 2014;513.
doi:10.1088/1742-6596/513/1/012013 .
Holme, O., Adžić, Petar, Di Calafiori, D., Dissertori, G., Djambazov, L., Jovanović, Dragana J., Lustermann, W., Zelepoukine, S., "The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System" in Journal of Physics: Conference Series, 513 (2014),
https://doi.org/10.1088/1742-6596/513/1/012013 . .