Konya, Zoltan

Link to this page

Authority KeyName Variants
acc3b096-7a16-4c27-872b-95eaa28622c1
  • Konya, Zoltan (1)
Projects

Author's Bibliography

Facile immobilization of cholesterol oxidase on Pt,Ru–C nanocomposite and ionic liquid–modified carbon paste electrode for an efficient amperometric free cholesterol biosensing

Mutić, Sanja; Stanković, Dalibor; Konya, Zoltan; Anojčić, Jasmina

(2023)

TY  - JOUR
AU  - Mutić, Sanja
AU  - Stanković, Dalibor
AU  - Konya, Zoltan
AU  - Anojčić, Jasmina
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11370
AB  - In present work, the enzyme cholesterol oxidase (ChOx) was immobilized by Nafion® (Naf) on Pt,Ru–C nanocomposite and an ionic liquid (IL)–modified carbon paste electrode (CPE) in order to create cholesterol biosensor (Naf/ChOx/Pt,Ru–C/IL-CPE). The prepared working electrodes were characterized using scanning electron microscopy–energy-dispersive spectrometry, while their electrochemical performance was evaluated using electrochemical impedance spectroscopic, cyclic voltammetric, and amperometric techniques. Excellent synergism between IL 1-allyl-3-methylimidazolium dicyanamide ([AMIM][DCA]), Pt,Ru–C, and ChOx, as modifiers of CPE, offers the most pronounced analytical performance for improved cholesterol amperometric determination in phosphate buffer solution pH 7.50 at a working potential of 0.60 V. Under optimized experimental conditions, a linear relationship between oxidation current and cholesterol concentration was found for the range from 0.31 to 2.46 µM, with an estimated detection limit of 0.13 µM and relative standard deviation (RSD) below 5.5%. The optimized amperometric method in combination with the developed Naf/ChOx/Pt,Ru–C/IL-CPE biosensor showed good repeatability and high selectivity towards cholesterol biosensing. The proposed biosensor was successfully applied to determine free cholesterol in a human blood serum sample via its enzymatic reaction product hydrogen peroxide despite the presence of possible interferences. The percentage recovery ranged from 99.08 to 102.81%, while RSD was below 2.0% for the unspiked as well as the spiked human blood serum sample. The obtained results indicated excellent accuracy and precision of the method, concluding that the developed biosensor can be a promising alternative to existing commercial cholesterol tests used in medical practice. Graphical abstract: [Figure not available: see fulltext.]. © 2023, The Author(s), under exclusive licence to Springer-Verlag GmbH, DE part of Springer Nature.
T2  - Analytical and Bioanalytical Chemistry
T1  - Facile immobilization of cholesterol oxidase on Pt,Ru–C nanocomposite and ionic liquid–modified carbon paste electrode for an efficient amperometric free cholesterol biosensing
DO  - 10.1007/s00216-023-04847-9
ER  - 
@article{
author = "Mutić, Sanja and Stanković, Dalibor and Konya, Zoltan and Anojčić, Jasmina",
year = "2023",
abstract = "In present work, the enzyme cholesterol oxidase (ChOx) was immobilized by Nafion® (Naf) on Pt,Ru–C nanocomposite and an ionic liquid (IL)–modified carbon paste electrode (CPE) in order to create cholesterol biosensor (Naf/ChOx/Pt,Ru–C/IL-CPE). The prepared working electrodes were characterized using scanning electron microscopy–energy-dispersive spectrometry, while their electrochemical performance was evaluated using electrochemical impedance spectroscopic, cyclic voltammetric, and amperometric techniques. Excellent synergism between IL 1-allyl-3-methylimidazolium dicyanamide ([AMIM][DCA]), Pt,Ru–C, and ChOx, as modifiers of CPE, offers the most pronounced analytical performance for improved cholesterol amperometric determination in phosphate buffer solution pH 7.50 at a working potential of 0.60 V. Under optimized experimental conditions, a linear relationship between oxidation current and cholesterol concentration was found for the range from 0.31 to 2.46 µM, with an estimated detection limit of 0.13 µM and relative standard deviation (RSD) below 5.5%. The optimized amperometric method in combination with the developed Naf/ChOx/Pt,Ru–C/IL-CPE biosensor showed good repeatability and high selectivity towards cholesterol biosensing. The proposed biosensor was successfully applied to determine free cholesterol in a human blood serum sample via its enzymatic reaction product hydrogen peroxide despite the presence of possible interferences. The percentage recovery ranged from 99.08 to 102.81%, while RSD was below 2.0% for the unspiked as well as the spiked human blood serum sample. The obtained results indicated excellent accuracy and precision of the method, concluding that the developed biosensor can be a promising alternative to existing commercial cholesterol tests used in medical practice. Graphical abstract: [Figure not available: see fulltext.]. © 2023, The Author(s), under exclusive licence to Springer-Verlag GmbH, DE part of Springer Nature.",
journal = "Analytical and Bioanalytical Chemistry",
title = "Facile immobilization of cholesterol oxidase on Pt,Ru–C nanocomposite and ionic liquid–modified carbon paste electrode for an efficient amperometric free cholesterol biosensing",
doi = "10.1007/s00216-023-04847-9"
}
Mutić, S., Stanković, D., Konya, Z.,& Anojčić, J.. (2023). Facile immobilization of cholesterol oxidase on Pt,Ru–C nanocomposite and ionic liquid–modified carbon paste electrode for an efficient amperometric free cholesterol biosensing. in Analytical and Bioanalytical Chemistry.
https://doi.org/10.1007/s00216-023-04847-9
Mutić S, Stanković D, Konya Z, Anojčić J. Facile immobilization of cholesterol oxidase on Pt,Ru–C nanocomposite and ionic liquid–modified carbon paste electrode for an efficient amperometric free cholesterol biosensing. in Analytical and Bioanalytical Chemistry. 2023;.
doi:10.1007/s00216-023-04847-9 .
Mutić, Sanja, Stanković, Dalibor, Konya, Zoltan, Anojčić, Jasmina, "Facile immobilization of cholesterol oxidase on Pt,Ru–C nanocomposite and ionic liquid–modified carbon paste electrode for an efficient amperometric free cholesterol biosensing" in Analytical and Bioanalytical Chemistry (2023),
https://doi.org/10.1007/s00216-023-04847-9 . .
2
3
1