Detailed optimization procedure of an HPGe detector using Geant4 toolkit

Travar, M.; Nikolov, Jovana; Todorović, N.; Vraničar, A.; Völgyesi, P.; Kirchknopf, P.; Čeliković, Igor T.; Milanović, Tamara J.; Joković, D.

(2023)

TY  - JOUR
AU  - Travar, M.
AU  - Nikolov, Jovana
AU  - Todorović, N.
AU  - Vraničar, A.
AU  - Völgyesi, P.
AU  - Kirchknopf, P.
AU  - Čeliković, Igor T.
AU  - Milanović, Tamara J.
AU  - Joković, D.
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10734
AB  - Presented study describes the optimization method of an HPGe detector through implementation of Geant4 toolkit. The optimized model was verified through comparison with experimentally obtained data using a set of point-like radioactive calibration sources. Acquired results displayed good agreement with the experimental data that falls under an average relative deviation of the order of ~ 2% within the energy range of 53–1836 keV. Additionally, in order to test the validity of the code it was also applied to a different detection equipment where an average relative deviation of the order of ~ 1.8% was achieved within the energy range of 121–1112 keV. © 2023, Akadémiai Kiadó, Budapest, Hungary.
T2  - Journal of Radioanalytical and Nuclear Chemistry
T1  - Detailed optimization procedure of an HPGe detector using Geant4 toolkit
VL  - 332
IS  - 3
SP  - 817
EP  - 828
DO  - 10.1007/s10967-023-08810-x
ER  - 
@article{
author = "Travar, M. and Nikolov, Jovana and Todorović, N. and Vraničar, A. and Völgyesi, P. and Kirchknopf, P. and Čeliković, Igor T. and Milanović, Tamara J. and Joković, D.",
year = "2023",
abstract = "Presented study describes the optimization method of an HPGe detector through implementation of Geant4 toolkit. The optimized model was verified through comparison with experimentally obtained data using a set of point-like radioactive calibration sources. Acquired results displayed good agreement with the experimental data that falls under an average relative deviation of the order of ~ 2% within the energy range of 53–1836 keV. Additionally, in order to test the validity of the code it was also applied to a different detection equipment where an average relative deviation of the order of ~ 1.8% was achieved within the energy range of 121–1112 keV. © 2023, Akadémiai Kiadó, Budapest, Hungary.",
journal = "Journal of Radioanalytical and Nuclear Chemistry",
title = "Detailed optimization procedure of an HPGe detector using Geant4 toolkit",
volume = "332",
number = "3",
pages = "817-828",
doi = "10.1007/s10967-023-08810-x"
}
Travar, M., Nikolov, J., Todorović, N., Vraničar, A., Völgyesi, P., Kirchknopf, P., Čeliković, I. T., Milanović, T. J.,& Joković, D.. (2023). Detailed optimization procedure of an HPGe detector using Geant4 toolkit. in Journal of Radioanalytical and Nuclear Chemistry, 332(3), 817-828.
https://doi.org/10.1007/s10967-023-08810-x
Travar M, Nikolov J, Todorović N, Vraničar A, Völgyesi P, Kirchknopf P, Čeliković IT, Milanović TJ, Joković D. Detailed optimization procedure of an HPGe detector using Geant4 toolkit. in Journal of Radioanalytical and Nuclear Chemistry. 2023;332(3):817-828.
doi:10.1007/s10967-023-08810-x .
Travar, M., Nikolov, Jovana, Todorović, N., Vraničar, A., Völgyesi, P., Kirchknopf, P., Čeliković, Igor T., Milanović, Tamara J., Joković, D., "Detailed optimization procedure of an HPGe detector using Geant4 toolkit" in Journal of Radioanalytical and Nuclear Chemistry, 332, no. 3 (2023):817-828,
https://doi.org/10.1007/s10967-023-08810-x . .