Comparison of calibration factors for field-class dosimeters

Živanović, Miloš Z.; Šabeta, Amra F.; Kržanović, Nikola; Makarić, Vedrana D.; Đaletić, Miloš; Stupar, Milica R.; Stanković, Srboljub

(2022)

TY  - JOUR
AU  - Živanović, Miloš Z.
AU  - Šabeta, Amra F.
AU  - Kržanović, Nikola
AU  - Makarić, Vedrana D.
AU  - Đaletić, Miloš
AU  - Stupar, Milica R.
AU  - Stanković, Srboljub
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10521
AB  - This paper presents a comparison performed between two calibration laboratories in several radiation qualities, using dosimeters of varying quality as transfer instruments. The goal of this work was to investigate the viability of using field-class dosimeters for official comparisons and to determine if the calibration factors for field-class dosimeters are comparable between calibration laboratories within the stated measurement uncertainties. The results of the comparison were acceptable for high-quality electronic personal dosimeters in all radiation qualities, and such dosimeters could be used as transfer instruments. On the other hand, comparison results for low-quality dosimeters were often not acceptable, either due to pronounced energy dependence, low stability, or both. Such instruments are unreliable even under well-defined laboratory conditions, and their use in routine measurements may cause doubt in official data or influence public opinion. This problem is often hidden because many dosimeters are calibrated or verified only in 137Cs beams, where the deviations are the smallest. The largest differences are found for low-energy X-ray radiation qualities, where many dosimeters have significant overresponse.
T2  - Nuclear Technology and Radiation Protection
T1  - Comparison of calibration factors for field-class dosimeters
VL  - 37
IS  - 2
SP  - 103
EP  - 110
DO  - 10.2298/NTRP2202103Z
ER  - 
@article{
author = "Živanović, Miloš Z. and Šabeta, Amra F. and Kržanović, Nikola and Makarić, Vedrana D. and Đaletić, Miloš and Stupar, Milica R. and Stanković, Srboljub",
year = "2022",
abstract = "This paper presents a comparison performed between two calibration laboratories in several radiation qualities, using dosimeters of varying quality as transfer instruments. The goal of this work was to investigate the viability of using field-class dosimeters for official comparisons and to determine if the calibration factors for field-class dosimeters are comparable between calibration laboratories within the stated measurement uncertainties. The results of the comparison were acceptable for high-quality electronic personal dosimeters in all radiation qualities, and such dosimeters could be used as transfer instruments. On the other hand, comparison results for low-quality dosimeters were often not acceptable, either due to pronounced energy dependence, low stability, or both. Such instruments are unreliable even under well-defined laboratory conditions, and their use in routine measurements may cause doubt in official data or influence public opinion. This problem is often hidden because many dosimeters are calibrated or verified only in 137Cs beams, where the deviations are the smallest. The largest differences are found for low-energy X-ray radiation qualities, where many dosimeters have significant overresponse.",
journal = "Nuclear Technology and Radiation Protection",
title = "Comparison of calibration factors for field-class dosimeters",
volume = "37",
number = "2",
pages = "103-110",
doi = "10.2298/NTRP2202103Z"
}
Živanović, M. Z., Šabeta, A. F., Kržanović, N., Makarić, V. D., Đaletić, M., Stupar, M. R.,& Stanković, S.. (2022). Comparison of calibration factors for field-class dosimeters. in Nuclear Technology and Radiation Protection, 37(2), 103-110.
https://doi.org/10.2298/NTRP2202103Z
Živanović MZ, Šabeta AF, Kržanović N, Makarić VD, Đaletić M, Stupar MR, Stanković S. Comparison of calibration factors for field-class dosimeters. in Nuclear Technology and Radiation Protection. 2022;37(2):103-110.
doi:10.2298/NTRP2202103Z .
Živanović, Miloš Z., Šabeta, Amra F., Kržanović, Nikola, Makarić, Vedrana D., Đaletić, Miloš, Stupar, Milica R., Stanković, Srboljub, "Comparison of calibration factors for field-class dosimeters" in Nuclear Technology and Radiation Protection, 37, no. 2 (2022):103-110,
https://doi.org/10.2298/NTRP2202103Z . .
1
1