Stevanović, N.

Link to this page

Authority KeyName Variants
8d5466e8-2b97-4193-b4ea-215d67d04f7d
  • Stevanović, N. (1)
Projects

Author's Bibliography

Determination of a CR-39 detector response to neutrons from an Am-Be source

Milenkovic, B.; Stevanović, N.; Nikezić, Dragoslav; Košutić, Duško D.

(2014)

TY  - JOUR
AU  - Milenkovic, B.
AU  - Stevanović, N.
AU  - Nikezić, Dragoslav
AU  - Košutić, Duško D.
PY  - 2014
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/346
AB  - A comparison of experimental and calculated responses of a CR-39 detector to neutron spectra from an Am-Be source is presented. Code named Neutron_CR-39.F90 has been used to calculate the neutron dose equivalent as well as the track density. Conversion coefficient (sensitivity), between track density in track/cm(2) and neutron dose equivalent in mSv, was calculated and good agreement with experimental data was found. Sensitivity increases linearly with removed layer in the range between 6 mu m and 24 mu m. (C) 2014 Elsevier Ltd. All rights reserved.
T2  - Applied Radiation and Isotopes
T1  - Determination of a CR-39 detector response to neutrons from an Am-Be source
VL  - 90
SP  - 225
EP  - 228
DO  - 10.1016/j.apradiso.2014.04.008
ER  - 
@article{
author = "Milenkovic, B. and Stevanović, N. and Nikezić, Dragoslav and Košutić, Duško D.",
year = "2014",
abstract = "A comparison of experimental and calculated responses of a CR-39 detector to neutron spectra from an Am-Be source is presented. Code named Neutron_CR-39.F90 has been used to calculate the neutron dose equivalent as well as the track density. Conversion coefficient (sensitivity), between track density in track/cm(2) and neutron dose equivalent in mSv, was calculated and good agreement with experimental data was found. Sensitivity increases linearly with removed layer in the range between 6 mu m and 24 mu m. (C) 2014 Elsevier Ltd. All rights reserved.",
journal = "Applied Radiation and Isotopes",
title = "Determination of a CR-39 detector response to neutrons from an Am-Be source",
volume = "90",
pages = "225-228",
doi = "10.1016/j.apradiso.2014.04.008"
}
Milenkovic, B., Stevanović, N., Nikezić, D.,& Košutić, D. D.. (2014). Determination of a CR-39 detector response to neutrons from an Am-Be source. in Applied Radiation and Isotopes, 90, 225-228.
https://doi.org/10.1016/j.apradiso.2014.04.008
Milenkovic B, Stevanović N, Nikezić D, Košutić DD. Determination of a CR-39 detector response to neutrons from an Am-Be source. in Applied Radiation and Isotopes. 2014;90:225-228.
doi:10.1016/j.apradiso.2014.04.008 .
Milenkovic, B., Stevanović, N., Nikezić, Dragoslav, Košutić, Duško D., "Determination of a CR-39 detector response to neutrons from an Am-Be source" in Applied Radiation and Isotopes, 90 (2014):225-228,
https://doi.org/10.1016/j.apradiso.2014.04.008 . .
4
2
4