Radon measurements during the building of a low-level laboratory

Antanasijevic, R; Aničin, Ivan V.; Bikit, Ištvan S.; Banjanac, R; Dragic, A; Joksimović, Danijela; Krmpotic, D; Udovičić, Vladimir; Vuković, Jasna V.

(1999)

TY  - JOUR
AU  - Antanasijevic, R
AU  - Aničin, Ivan V.
AU  - Bikit, Ištvan S.
AU  - Banjanac, R
AU  - Dragic, A
AU  - Joksimović, Danijela
AU  - Krmpotic, D
AU  - Udovičić, Vladimir
AU  - Vuković, Jasna V.
PY  - 1999
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/6281
AB  - Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m(2). The whole of the laboratory is hermetically lined with 1 mm Al foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm(-3) and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied.
T2  - Radiation Measurements
T1  - Radon measurements during the building of a low-level laboratory
VL  - 31
IS  - 1-6
SP  - 371
EP  - 374
DO  - 10.1016/S1350-4487(99)00177-8
ER  - 
@article{
author = "Antanasijevic, R and Aničin, Ivan V. and Bikit, Ištvan S. and Banjanac, R and Dragic, A and Joksimović, Danijela and Krmpotic, D and Udovičić, Vladimir and Vuković, Jasna V.",
year = "1999",
abstract = "Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m(2). The whole of the laboratory is hermetically lined with 1 mm Al foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm(-3) and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied.",
journal = "Radiation Measurements",
title = "Radon measurements during the building of a low-level laboratory",
volume = "31",
number = "1-6",
pages = "371-374",
doi = "10.1016/S1350-4487(99)00177-8"
}
Antanasijevic, R., Aničin, I. V., Bikit, I. S., Banjanac, R., Dragic, A., Joksimović, D., Krmpotic, D., Udovičić, V.,& Vuković, J. V.. (1999). Radon measurements during the building of a low-level laboratory. in Radiation Measurements, 31(1-6), 371-374.
https://doi.org/10.1016/S1350-4487(99)00177-8
Antanasijevic R, Aničin IV, Bikit IS, Banjanac R, Dragic A, Joksimović D, Krmpotic D, Udovičić V, Vuković JV. Radon measurements during the building of a low-level laboratory. in Radiation Measurements. 1999;31(1-6):371-374.
doi:10.1016/S1350-4487(99)00177-8 .
Antanasijevic, R, Aničin, Ivan V., Bikit, Ištvan S., Banjanac, R, Dragic, A, Joksimović, Danijela, Krmpotic, D, Udovičić, Vladimir, Vuković, Jasna V., "Radon measurements during the building of a low-level laboratory" in Radiation Measurements, 31, no. 1-6 (1999):371-374,
https://doi.org/10.1016/S1350-4487(99)00177-8 . .
11
9
13