Rout, R. P.

Link to this page

Authority KeyName Variants
1d6abf3f-6987-4755-85e0-ff9e0827549d
  • Rout, R. P. (1)
Projects

Author's Bibliography

Results from Time Integrated Measurements of Indoor Radon, Thoron and Their Decay Product Concentrations in Schools in the Republic of Macedonia

Stojanovska, Zdenka A.; Žunić, Zora S.; Bossew, Peter; Bochicchio, Francesco; Carpentieri, Carmela; Venoso, Gennaro; Mishra, Rosaline; Rout, R. P.; Sapra, B. K.; Burghele, Bety D.; Cucos-Dinu, A.; Boev, Blažo; Cosma, C.

(2014)

TY  - JOUR
AU  - Stojanovska, Zdenka A.
AU  - Žunić, Zora S.
AU  - Bossew, Peter
AU  - Bochicchio, Francesco
AU  - Carpentieri, Carmela
AU  - Venoso, Gennaro
AU  - Mishra, Rosaline
AU  - Rout, R. P.
AU  - Sapra, B. K.
AU  - Burghele, Bety D.
AU  - Cucos-Dinu, A.
AU  - Boev, Blažo
AU  - Cosma, C.
PY  - 2014
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7050
AB  - As part of a survey on concentrations of radon, thoron and their decay products in different indoor environments of the Balkan region involving international collaboration, measurements were performed in 43 schools from 5 municipalities of the Republic of Macedonia. The time-integrated radon and thoron gas concentrations (C-Rn and C-Tn) were measured by CR-39 (placed in chambers with different diffusion barriers), whereas the equilibrium equivalent radon and thoron concentrations (EERC and EETC) were measured using direct radon-thoron progeny sensors consisting of LR-115 nuclear track detectors. The detectors were deployed at a distance of at least 0.5 m from the walls as well as far away from the windows and doors in order to obtain more representative samples of air from the breathing zone; detectors were exposed over a 3-month period (March-May 2012). The geometric mean (GM) values [and geometric standard deviations (GSDs)] of C-Rn, C-Tn, EERC and EETC were 76 (1.7), 12 (2.3), 27 (1.4) and 0.75 Bq m(-3) (2.5), respectively. The equilibrium factors between radon and its decay products (F-Rn) and thoron and its decay products (F-Tn( GT 0.5) m) were evaluated: FRn ranged between 0.10 and 0.84 and F-Tn( GT 0.5) m ranged between 0.003 and 0.998 with GMs (and GSDs) equal to 0.36 (1.7) and 0.07 (3.4), respectively.
T2  - Radiation Protection Dosimetry
T1  - Results from Time Integrated Measurements of Indoor Radon, Thoron and Their Decay Product Concentrations in Schools in the Republic of Macedonia
VL  - 162
IS  - 1-2
SP  - 152
EP  - 156
DO  - 10.1093/rpd/ncu249
ER  - 
@article{
author = "Stojanovska, Zdenka A. and Žunić, Zora S. and Bossew, Peter and Bochicchio, Francesco and Carpentieri, Carmela and Venoso, Gennaro and Mishra, Rosaline and Rout, R. P. and Sapra, B. K. and Burghele, Bety D. and Cucos-Dinu, A. and Boev, Blažo and Cosma, C.",
year = "2014",
abstract = "As part of a survey on concentrations of radon, thoron and their decay products in different indoor environments of the Balkan region involving international collaboration, measurements were performed in 43 schools from 5 municipalities of the Republic of Macedonia. The time-integrated radon and thoron gas concentrations (C-Rn and C-Tn) were measured by CR-39 (placed in chambers with different diffusion barriers), whereas the equilibrium equivalent radon and thoron concentrations (EERC and EETC) were measured using direct radon-thoron progeny sensors consisting of LR-115 nuclear track detectors. The detectors were deployed at a distance of at least 0.5 m from the walls as well as far away from the windows and doors in order to obtain more representative samples of air from the breathing zone; detectors were exposed over a 3-month period (March-May 2012). The geometric mean (GM) values [and geometric standard deviations (GSDs)] of C-Rn, C-Tn, EERC and EETC were 76 (1.7), 12 (2.3), 27 (1.4) and 0.75 Bq m(-3) (2.5), respectively. The equilibrium factors between radon and its decay products (F-Rn) and thoron and its decay products (F-Tn( GT 0.5) m) were evaluated: FRn ranged between 0.10 and 0.84 and F-Tn( GT 0.5) m ranged between 0.003 and 0.998 with GMs (and GSDs) equal to 0.36 (1.7) and 0.07 (3.4), respectively.",
journal = "Radiation Protection Dosimetry",
title = "Results from Time Integrated Measurements of Indoor Radon, Thoron and Their Decay Product Concentrations in Schools in the Republic of Macedonia",
volume = "162",
number = "1-2",
pages = "152-156",
doi = "10.1093/rpd/ncu249"
}
Stojanovska, Z. A., Žunić, Z. S., Bossew, P., Bochicchio, F., Carpentieri, C., Venoso, G., Mishra, R., Rout, R. P., Sapra, B. K., Burghele, B. D., Cucos-Dinu, A., Boev, B.,& Cosma, C.. (2014). Results from Time Integrated Measurements of Indoor Radon, Thoron and Their Decay Product Concentrations in Schools in the Republic of Macedonia. in Radiation Protection Dosimetry, 162(1-2), 152-156.
https://doi.org/10.1093/rpd/ncu249
Stojanovska ZA, Žunić ZS, Bossew P, Bochicchio F, Carpentieri C, Venoso G, Mishra R, Rout RP, Sapra BK, Burghele BD, Cucos-Dinu A, Boev B, Cosma C. Results from Time Integrated Measurements of Indoor Radon, Thoron and Their Decay Product Concentrations in Schools in the Republic of Macedonia. in Radiation Protection Dosimetry. 2014;162(1-2):152-156.
doi:10.1093/rpd/ncu249 .
Stojanovska, Zdenka A., Žunić, Zora S., Bossew, Peter, Bochicchio, Francesco, Carpentieri, Carmela, Venoso, Gennaro, Mishra, Rosaline, Rout, R. P., Sapra, B. K., Burghele, Bety D., Cucos-Dinu, A., Boev, Blažo, Cosma, C., "Results from Time Integrated Measurements of Indoor Radon, Thoron and Their Decay Product Concentrations in Schools in the Republic of Macedonia" in Radiation Protection Dosimetry, 162, no. 1-2 (2014):152-156,
https://doi.org/10.1093/rpd/ncu249 . .
25
24
28