Establishing the European diagnostic reference levels for interventional cardiology

Siiskonen, Teemu; Ciraj-Bjelac, Olivera; Dabin, Jeremie; Diklić, Ana; Domienik-Andrzejewska, Joanna; Farah, Jad; Fernandez, Jose Miguel; Gallagher, Aoife; Hourdakis, Constantine J.; Jurković, Slaven; Jarvinen, Hannu; Jarvinen, J.; Knežević, Željka; Koukorava, Christina; Maccia, Carlo; Majer, Marija; Malchair, Francoise; Riccardi, Lucia; Rizk, C.; Sanchez, Roberto Mariano; Sandborg, Michael; Merce, Marta Sans; Segota, D.; Sierpowska, Joanna; Simantirakis, George; Sukupova, Lucie; Thrapsanioti, Zoi; Vano, Eliseo

(2018)

TY  - JOUR
AU  - Siiskonen, Teemu
AU  - Ciraj-Bjelac, Olivera
AU  - Dabin, Jeremie
AU  - Diklić, Ana
AU  - Domienik-Andrzejewska, Joanna
AU  - Farah, Jad
AU  - Fernandez, Jose Miguel
AU  - Gallagher, Aoife
AU  - Hourdakis, Constantine J.
AU  - Jurković, Slaven
AU  - Jarvinen, Hannu
AU  - Jarvinen, J.
AU  - Knežević, Željka
AU  - Koukorava, Christina
AU  - Maccia, Carlo
AU  - Majer, Marija
AU  - Malchair, Francoise
AU  - Riccardi, Lucia
AU  - Rizk, C.
AU  - Sanchez, Roberto Mariano
AU  - Sandborg, Michael
AU  - Merce, Marta Sans
AU  - Segota, D.
AU  - Sierpowska, Joanna
AU  - Simantirakis, George
AU  - Sukupova, Lucie
AU  - Thrapsanioti, Zoi
AU  - Vano, Eliseo
PY  - 2018
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7889
AB  - Interventional cardiac procedures may be associated with high patient doses and therefore require special attention to protect the patients from radiation injuries such as skin erythema, cardiovascular tissue reactions or radiation-induced cancer. In this study, patient exposure data is collected from 13 countries (37 clinics and nearly 50 interventional rooms) and for 10 different procedures. Dose data was collected from a total of 14,922 interventional cardiology procedures. Based on these data European diagnostic reference levels (DRL) for air kerma-area product are suggested for coronary angiography (CA, DRL = 35 Gy cm2), percutaneous coronary intervention (PCI, 85 Gy cm2), transcatheter aortic valve implantation (TAVI, 130 Gy cm2), electrophysiological procedures (12 Gy cm2) and pacemaker implantations. Pacemaker implantations were further divided into single-chamber (2.5 Gy cm2) and dual chamber (3.5 Gy cm2) procedures and implantations of cardiac resynchronization therapy pacemaker (18 Gy cm2). Results show that relatively new techniques such as TAVI and treatment of chronic total occlusion (CTO) often produce relatively high doses, and thus emphasises the need for use of an optimization tool such as DRL to assist in reducing patient exposure. The generic DRL presented here facilitate comparison of patient exposure in interventional cardiology. © 2018 Associazione Italiana di Fisica Medica
T2  - Physica Medica
T1  - Establishing the European diagnostic reference levels for interventional cardiology
VL  - 54
SP  - 42
EP  - 48
DO  - 10.1016/j.ejmp.2018.09.012
ER  - 
@article{
author = "Siiskonen, Teemu and Ciraj-Bjelac, Olivera and Dabin, Jeremie and Diklić, Ana and Domienik-Andrzejewska, Joanna and Farah, Jad and Fernandez, Jose Miguel and Gallagher, Aoife and Hourdakis, Constantine J. and Jurković, Slaven and Jarvinen, Hannu and Jarvinen, J. and Knežević, Željka and Koukorava, Christina and Maccia, Carlo and Majer, Marija and Malchair, Francoise and Riccardi, Lucia and Rizk, C. and Sanchez, Roberto Mariano and Sandborg, Michael and Merce, Marta Sans and Segota, D. and Sierpowska, Joanna and Simantirakis, George and Sukupova, Lucie and Thrapsanioti, Zoi and Vano, Eliseo",
year = "2018",
abstract = "Interventional cardiac procedures may be associated with high patient doses and therefore require special attention to protect the patients from radiation injuries such as skin erythema, cardiovascular tissue reactions or radiation-induced cancer. In this study, patient exposure data is collected from 13 countries (37 clinics and nearly 50 interventional rooms) and for 10 different procedures. Dose data was collected from a total of 14,922 interventional cardiology procedures. Based on these data European diagnostic reference levels (DRL) for air kerma-area product are suggested for coronary angiography (CA, DRL = 35 Gy cm2), percutaneous coronary intervention (PCI, 85 Gy cm2), transcatheter aortic valve implantation (TAVI, 130 Gy cm2), electrophysiological procedures (12 Gy cm2) and pacemaker implantations. Pacemaker implantations were further divided into single-chamber (2.5 Gy cm2) and dual chamber (3.5 Gy cm2) procedures and implantations of cardiac resynchronization therapy pacemaker (18 Gy cm2). Results show that relatively new techniques such as TAVI and treatment of chronic total occlusion (CTO) often produce relatively high doses, and thus emphasises the need for use of an optimization tool such as DRL to assist in reducing patient exposure. The generic DRL presented here facilitate comparison of patient exposure in interventional cardiology. © 2018 Associazione Italiana di Fisica Medica",
journal = "Physica Medica",
title = "Establishing the European diagnostic reference levels for interventional cardiology",
volume = "54",
pages = "42-48",
doi = "10.1016/j.ejmp.2018.09.012"
}
Siiskonen, T., Ciraj-Bjelac, O., Dabin, J., Diklić, A., Domienik-Andrzejewska, J., Farah, J., Fernandez, J. M., Gallagher, A., Hourdakis, C. J., Jurković, S., Jarvinen, H., Jarvinen, J., Knežević, Ž., Koukorava, C., Maccia, C., Majer, M., Malchair, F., Riccardi, L., Rizk, C., Sanchez, R. M., Sandborg, M., Merce, M. S., Segota, D., Sierpowska, J., Simantirakis, G., Sukupova, L., Thrapsanioti, Z.,& Vano, E.. (2018). Establishing the European diagnostic reference levels for interventional cardiology. in Physica Medica, 54, 42-48.
https://doi.org/10.1016/j.ejmp.2018.09.012
Siiskonen T, Ciraj-Bjelac O, Dabin J, Diklić A, Domienik-Andrzejewska J, Farah J, Fernandez JM, Gallagher A, Hourdakis CJ, Jurković S, Jarvinen H, Jarvinen J, Knežević Ž, Koukorava C, Maccia C, Majer M, Malchair F, Riccardi L, Rizk C, Sanchez RM, Sandborg M, Merce MS, Segota D, Sierpowska J, Simantirakis G, Sukupova L, Thrapsanioti Z, Vano E. Establishing the European diagnostic reference levels for interventional cardiology. in Physica Medica. 2018;54:42-48.
doi:10.1016/j.ejmp.2018.09.012 .
Siiskonen, Teemu, Ciraj-Bjelac, Olivera, Dabin, Jeremie, Diklić, Ana, Domienik-Andrzejewska, Joanna, Farah, Jad, Fernandez, Jose Miguel, Gallagher, Aoife, Hourdakis, Constantine J., Jurković, Slaven, Jarvinen, Hannu, Jarvinen, J., Knežević, Željka, Koukorava, Christina, Maccia, Carlo, Majer, Marija, Malchair, Francoise, Riccardi, Lucia, Rizk, C., Sanchez, Roberto Mariano, Sandborg, Michael, Merce, Marta Sans, Segota, D., Sierpowska, Joanna, Simantirakis, George, Sukupova, Lucie, Thrapsanioti, Zoi, Vano, Eliseo, "Establishing the European diagnostic reference levels for interventional cardiology" in Physica Medica, 54 (2018):42-48,
https://doi.org/10.1016/j.ejmp.2018.09.012 . .
35
23
33