Towards the definition of the optimum height of voluminous cylindrical sources in gamma-ray spectroscopy

Vesić, D.; Puzović, Jovan M.; Aničin, Ivan V.

(1999)

TY  - JOUR
AU  - Vesić, D.
AU  - Puzović, Jovan M.
AU  - Aničin, Ivan V.
PY  - 1999
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/2242
AB  - We show that for cylindrical voluminous sources in gamma-ray spectroscopy the relative error of the spectral intensity of a low-energy spectral line, as the height of the source increases, saturates faster than the spectral intensity itself. This significantly reduces the quantity of the required sample material as compared to that based on the usual considerations of the spectral intensity only. We also demonstrate that there exists a weakly pronounced height of the source (the sourer size) which minimizes the relative error of the intensity of a given low-energy spectral line, Due to the smallness of the effect the benefit of introducing the concept of the truly optimum size of the source is more on a psychological side, one should feel easier using an optimum quantity of the source material than merely a sufficient one, as is otherwise the case. (C) 1999 Elsevier Science Ltd. All rights reserved.
T2  - Applied Radiation and Isotopes
T1  - Towards the definition of the optimum height of voluminous cylindrical sources in gamma-ray spectroscopy
VL  - 50
IS  - 6
SP  - 999
EP  - 1001
DO  - 10.1016/S0969-8043(98)00172-9
ER  - 
@article{
author = "Vesić, D. and Puzović, Jovan M. and Aničin, Ivan V.",
year = "1999",
abstract = "We show that for cylindrical voluminous sources in gamma-ray spectroscopy the relative error of the spectral intensity of a low-energy spectral line, as the height of the source increases, saturates faster than the spectral intensity itself. This significantly reduces the quantity of the required sample material as compared to that based on the usual considerations of the spectral intensity only. We also demonstrate that there exists a weakly pronounced height of the source (the sourer size) which minimizes the relative error of the intensity of a given low-energy spectral line, Due to the smallness of the effect the benefit of introducing the concept of the truly optimum size of the source is more on a psychological side, one should feel easier using an optimum quantity of the source material than merely a sufficient one, as is otherwise the case. (C) 1999 Elsevier Science Ltd. All rights reserved.",
journal = "Applied Radiation and Isotopes",
title = "Towards the definition of the optimum height of voluminous cylindrical sources in gamma-ray spectroscopy",
volume = "50",
number = "6",
pages = "999-1001",
doi = "10.1016/S0969-8043(98)00172-9"
}
Vesić, D., Puzović, J. M.,& Aničin, I. V.. (1999). Towards the definition of the optimum height of voluminous cylindrical sources in gamma-ray spectroscopy. in Applied Radiation and Isotopes, 50(6), 999-1001.
https://doi.org/10.1016/S0969-8043(98)00172-9
Vesić D, Puzović JM, Aničin IV. Towards the definition of the optimum height of voluminous cylindrical sources in gamma-ray spectroscopy. in Applied Radiation and Isotopes. 1999;50(6):999-1001.
doi:10.1016/S0969-8043(98)00172-9 .
Vesić, D., Puzović, Jovan M., Aničin, Ivan V., "Towards the definition of the optimum height of voluminous cylindrical sources in gamma-ray spectroscopy" in Applied Radiation and Isotopes, 50, no. 6 (1999):999-1001,
https://doi.org/10.1016/S0969-8043(98)00172-9 . .