@conference{
author = "Antić, Vojislav and Ciraj-Bjelac, Olivera and Selaković, Jovana and Božović, Predrag and Aranđić, Danijela and Pavlović, Siniša",
year = "2017",
abstract = "Ovaj rad ima za cilj procenu izloženosti očnog sočiva profesionalno izloženih lica
tokom CRT procedura na bazi direktnih merenja aktivnim dozimetrom u Hp(3) doznom
ekvivalentu. Ustanovljena je srednja vrednost doze po intervenciji od 30µSv za
kardiologe, 26 µSv za medicinske tehničare, odnosno 2µSv za radiološke tehničare.
Normalizovane vrednosti Hp(3)/PKA su iznosile 1,2 ± 0,34µSv, 0,98 ± 0,57µSv, odnosno
0,10 ± 0,08, respektivno. Položaj kardiologa, od centralne linije primarnog snopa, je
bio 45-55cm a medicinskog tehničara 80-200cm. Osim pri standardnom AP položaju,
fluoroskopsko praćenje je bilo i u kosoj projekciji, ali u relativno zanemarljivom
vremenu. Osoblje je zaštitne naočare nosilo samo u 15,8% analiziranih procedura (u 6
od ukupno 38). Razmatran je uticaj FT-a, PKA-a, strukturalne zaštite i ličnih zaštitnih
sredstava pri CRT interventnim procedurama, u cilju optimizacije zaštite očnog sočiva
od uticaja jonizujućeg zračenja., This study aims to assess the exposure of the staff eye lens during CRT procedures,
based on direct measurements with an active dosimeter in Hp(3) operational quantity.
The mean doses per intervention of 30µSv, 26µSv and 2µSv was established for
cardiologists, medical technicians and radiological technicians, respectively.
Corresponding normalized values of Hp(3)/PKA were 1.2 ± 0.34 µSv, 0.98 ± 0.57 µSv,
and 0.10 ± 0.08. Cardiologists position relative to the center line of the primary beam
was in the range from 45 to 55cm. For medical technician, this distance was 80-200cm.
In addition to the standard AP position, fluoroscopic monitoring was also in oblique
projection, but in a relatively negligible time. Staff wore goggles only in 15.8% of the
analyzed procedures (6 of 38). In order to protect the eye lens from the influence of
ionizing radiation during CRT interventional procedures, the overall impact of the FT,
PKA, structural protection and personal protective equipment were carefully
considered.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "29. симпозијум ДЗЗСЦГ : зборник радова",
title = "Procena doze za očno sočivo za profesionalno izložena lica tokom CRT procedura, Eye lens dose assessment for occupationally exposed persons during CRT procedures",
pages = "249-253",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8281"
}