Carelli, V.

Link to this page

Authority KeyName Variants
1f74d5e5-23e1-4367-b79f-5d297b9b200e
  • Carelli, V. (3)
Projects

Author's Bibliography

Radon in indoor air of primary schools: a systematic survey to evaluate factors affecting radon concentration levels and their variability

Bochicchio, Francesco; Žunić, Zora S.; Carpentieri, Carmen; Antignani, Sara; Venoso, Gennaro; Carelli, V.; Cordedda, C.; Veselinović, Nenad; Tollefsen, Tore B.; Bossew, Peter

(2014)

TY  - JOUR
AU  - Bochicchio, Francesco
AU  - Žunić, Zora S.
AU  - Carpentieri, Carmen
AU  - Antignani, Sara
AU  - Venoso, Gennaro
AU  - Carelli, V.
AU  - Cordedda, C.
AU  - Veselinović, Nenad
AU  - Tollefsen, Tore B.
AU  - Bossew, Peter
PY  - 2014
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/5967
AB  - In order to optimize the design of a national survey aimed to evaluate radon exposure of children in schools in Serbia, a pilot study was carried out in all the 334 primary schools of 13 municipalities of Southern Serbia. Based on data from passive measurements, rooms with annual radon concentration GT 300Bq/m(3) were found in 5% of schools. The mean annual radon concentration weighted with the number of pupils is 73Bq/m(3), 39% lower than the unweighted 119Bq/m(3) average concentration. The actual average concentration when children are in classrooms could be substantially lower. Variability between schools (CV=65%), between floors (CV=24%) and between rooms at the same floor (CV=21%) was analyzed. The impact of school location, floor, and room usage on radon concentration was also assessed (with similar results) by univariate and multivariate analyses. On average, radon concentration in schools within towns is a factor of 0.60 lower than in villages and at higher floors is a factor of 0.68 lower than ground floor. Results can be useful for other countries with similar soil and building characteristics.
T2  - Indoor Air
T1  - Radon in indoor air of primary schools: a systematic survey to evaluate factors affecting radon concentration levels and their variability
VL  - 24
IS  - 3
SP  - 315
EP  - 326
DO  - 10.1111/ina.12073
ER  - 
@article{
author = "Bochicchio, Francesco and Žunić, Zora S. and Carpentieri, Carmen and Antignani, Sara and Venoso, Gennaro and Carelli, V. and Cordedda, C. and Veselinović, Nenad and Tollefsen, Tore B. and Bossew, Peter",
year = "2014",
abstract = "In order to optimize the design of a national survey aimed to evaluate radon exposure of children in schools in Serbia, a pilot study was carried out in all the 334 primary schools of 13 municipalities of Southern Serbia. Based on data from passive measurements, rooms with annual radon concentration GT 300Bq/m(3) were found in 5% of schools. The mean annual radon concentration weighted with the number of pupils is 73Bq/m(3), 39% lower than the unweighted 119Bq/m(3) average concentration. The actual average concentration when children are in classrooms could be substantially lower. Variability between schools (CV=65%), between floors (CV=24%) and between rooms at the same floor (CV=21%) was analyzed. The impact of school location, floor, and room usage on radon concentration was also assessed (with similar results) by univariate and multivariate analyses. On average, radon concentration in schools within towns is a factor of 0.60 lower than in villages and at higher floors is a factor of 0.68 lower than ground floor. Results can be useful for other countries with similar soil and building characteristics.",
journal = "Indoor Air",
title = "Radon in indoor air of primary schools: a systematic survey to evaluate factors affecting radon concentration levels and their variability",
volume = "24",
number = "3",
pages = "315-326",
doi = "10.1111/ina.12073"
}
Bochicchio, F., Žunić, Z. S., Carpentieri, C., Antignani, S., Venoso, G., Carelli, V., Cordedda, C., Veselinović, N., Tollefsen, T. B.,& Bossew, P.. (2014). Radon in indoor air of primary schools: a systematic survey to evaluate factors affecting radon concentration levels and their variability. in Indoor Air, 24(3), 315-326.
https://doi.org/10.1111/ina.12073
Bochicchio F, Žunić ZS, Carpentieri C, Antignani S, Venoso G, Carelli V, Cordedda C, Veselinović N, Tollefsen TB, Bossew P. Radon in indoor air of primary schools: a systematic survey to evaluate factors affecting radon concentration levels and their variability. in Indoor Air. 2014;24(3):315-326.
doi:10.1111/ina.12073 .
Bochicchio, Francesco, Žunić, Zora S., Carpentieri, Carmen, Antignani, Sara, Venoso, Gennaro, Carelli, V., Cordedda, C., Veselinović, Nenad, Tollefsen, Tore B., Bossew, Peter, "Radon in indoor air of primary schools: a systematic survey to evaluate factors affecting radon concentration levels and their variability" in Indoor Air, 24, no. 3 (2014):315-326,
https://doi.org/10.1111/ina.12073 . .
3
39
36
45

Some Results of a Radon Survey in 207 Serbian Schools

Žunić, Zora S.; Carpentieri, Carmen; Stojanovska, Zdenka A.; Antignani, Sara; Veselinović, Nenad; Tollefsen, Tore B.; Carelli, V.; Cordedda, C.; Cuknic, O.; Filipović, Jelena G.; Bossew, Peter; Bochicchio, Francesco

(2013)

TY  - JOUR
AU  - Žunić, Zora S.
AU  - Carpentieri, Carmen
AU  - Stojanovska, Zdenka A.
AU  - Antignani, Sara
AU  - Veselinović, Nenad
AU  - Tollefsen, Tore B.
AU  - Carelli, V.
AU  - Cordedda, C.
AU  - Cuknic, O.
AU  - Filipović, Jelena G.
AU  - Bossew, Peter
AU  - Bochicchio, Francesco
PY  - 2013
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7001
AB  - In this paper the results of radon concentration measurements performed in 207 schools in 7 communities of Southern Serbia are presented. The annual radon concentration varied from 17 Bqm(-3) to 428 Bqm(-3) with a median value of 96 Bqm(-3). The arithmetic mean (AM) of the 207 annual averages was 118 Bqm(-3) with a standard deviation (SD) of 78 Bqm(-3). The best distribution fitting of radon concentration by log-normal function was obtained. The log-normal parameters are the following: geometric mean (GM) = 97 Bqm(-3), geometric standard deviation (GSD) = 1.9. In addition, a spatial distribution of the indoor radon concentration over the investigated areas is observed.
T2  - Romanian Journal of Physics
T1  - Some Results of a Radon Survey in 207 Serbian Schools
VL  - 58
SP  - S320
EP  - S327
UR  - https://hdl.handle.net/21.15107/rcub_vinar_7001
ER  - 
@article{
author = "Žunić, Zora S. and Carpentieri, Carmen and Stojanovska, Zdenka A. and Antignani, Sara and Veselinović, Nenad and Tollefsen, Tore B. and Carelli, V. and Cordedda, C. and Cuknic, O. and Filipović, Jelena G. and Bossew, Peter and Bochicchio, Francesco",
year = "2013",
abstract = "In this paper the results of radon concentration measurements performed in 207 schools in 7 communities of Southern Serbia are presented. The annual radon concentration varied from 17 Bqm(-3) to 428 Bqm(-3) with a median value of 96 Bqm(-3). The arithmetic mean (AM) of the 207 annual averages was 118 Bqm(-3) with a standard deviation (SD) of 78 Bqm(-3). The best distribution fitting of radon concentration by log-normal function was obtained. The log-normal parameters are the following: geometric mean (GM) = 97 Bqm(-3), geometric standard deviation (GSD) = 1.9. In addition, a spatial distribution of the indoor radon concentration over the investigated areas is observed.",
journal = "Romanian Journal of Physics",
title = "Some Results of a Radon Survey in 207 Serbian Schools",
volume = "58",
pages = "S320-S327",
url = "https://hdl.handle.net/21.15107/rcub_vinar_7001"
}
Žunić, Z. S., Carpentieri, C., Stojanovska, Z. A., Antignani, S., Veselinović, N., Tollefsen, T. B., Carelli, V., Cordedda, C., Cuknic, O., Filipović, J. G., Bossew, P.,& Bochicchio, F.. (2013). Some Results of a Radon Survey in 207 Serbian Schools. in Romanian Journal of Physics, 58, S320-S327.
https://hdl.handle.net/21.15107/rcub_vinar_7001
Žunić ZS, Carpentieri C, Stojanovska ZA, Antignani S, Veselinović N, Tollefsen TB, Carelli V, Cordedda C, Cuknic O, Filipović JG, Bossew P, Bochicchio F. Some Results of a Radon Survey in 207 Serbian Schools. in Romanian Journal of Physics. 2013;58:S320-S327.
https://hdl.handle.net/21.15107/rcub_vinar_7001 .
Žunić, Zora S., Carpentieri, Carmen, Stojanovska, Zdenka A., Antignani, Sara, Veselinović, Nenad, Tollefsen, Tore B., Carelli, V., Cordedda, C., Cuknic, O., Filipović, Jelena G., Bossew, Peter, Bochicchio, Francesco, "Some Results of a Radon Survey in 207 Serbian Schools" in Romanian Journal of Physics, 58 (2013):S320-S327,
https://hdl.handle.net/21.15107/rcub_vinar_7001 .
15

Assessment of Long-Term Radon Concentration Measurement Precision in Field Conditions (Serbian Schools) for a Survey Carried Out By An International Collaboration

Carpentieri, Carmen; Žunić, Zora S.; Carelli, V.; Cordedda, C.; Ferrigno, G.; Veselinović, Nenad; Bossew, Peter; Tollefsen, Tore B.; Cuknic, O.; Vojinovic, Z.; Bochicchio, Francesco

(2011)

TY  - JOUR
AU  - Carpentieri, Carmen
AU  - Žunić, Zora S.
AU  - Carelli, V.
AU  - Cordedda, C.
AU  - Ferrigno, G.
AU  - Veselinović, Nenad
AU  - Bossew, Peter
AU  - Tollefsen, Tore B.
AU  - Cuknic, O.
AU  - Vojinovic, Z.
AU  - Bochicchio, Francesco
PY  - 2011
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/4319
AB  - In an international collaboration, a long-term radon concentration survey was carried out in schools of Southern Serbia with radon detectors prepared, etched and read-out in Italy. In such surveys it is necessary to evaluate measurement precision in field conditions, and to check whether quality assurance protocols were effective in keeping uncertainties under control, despite the complex organisation of measurements. In the first stage of the survey, which involves only some of the total number of municipalities, paired detectors were exposed in each monitored room in order to experimentally assess measurement precision. Paired passive devices (containing CR-39 detectors) were exposed for two consecutive 6-month periods. Two different measurement systems were used to read out CR-39s of the first and second period, respectively. The median of the coefficient of variation (CV) of the measured exposures was 8 % for 232 paired devices of the first 6-month period and 4 % for 242 paired devices of the second 6-month period, respectively. This difference was mainly due to a different track count repeatability of the two read-out systems, which was 4 and 1 %, respectively, as the median value of CV of repeated countings. The in-field measured precision results are very similar to the precision assessed in calibration conditions and are much lower than the room-to-room variation of radon concentration in the monitored schools. Moreover, a quality assurance protocol was followed to reduce extra-exposures during detector transport from Rome to schools measured and back.
T2  - Radiation Protection Dosimetry
T1  - Assessment of Long-Term Radon Concentration Measurement Precision in Field Conditions (Serbian Schools) for a Survey Carried Out By An International Collaboration
VL  - 145
IS  - 2-3
SP  - 305
EP  - 311
DO  - 10.1093/rpd/ncr042
ER  - 
@article{
author = "Carpentieri, Carmen and Žunić, Zora S. and Carelli, V. and Cordedda, C. and Ferrigno, G. and Veselinović, Nenad and Bossew, Peter and Tollefsen, Tore B. and Cuknic, O. and Vojinovic, Z. and Bochicchio, Francesco",
year = "2011",
abstract = "In an international collaboration, a long-term radon concentration survey was carried out in schools of Southern Serbia with radon detectors prepared, etched and read-out in Italy. In such surveys it is necessary to evaluate measurement precision in field conditions, and to check whether quality assurance protocols were effective in keeping uncertainties under control, despite the complex organisation of measurements. In the first stage of the survey, which involves only some of the total number of municipalities, paired detectors were exposed in each monitored room in order to experimentally assess measurement precision. Paired passive devices (containing CR-39 detectors) were exposed for two consecutive 6-month periods. Two different measurement systems were used to read out CR-39s of the first and second period, respectively. The median of the coefficient of variation (CV) of the measured exposures was 8 % for 232 paired devices of the first 6-month period and 4 % for 242 paired devices of the second 6-month period, respectively. This difference was mainly due to a different track count repeatability of the two read-out systems, which was 4 and 1 %, respectively, as the median value of CV of repeated countings. The in-field measured precision results are very similar to the precision assessed in calibration conditions and are much lower than the room-to-room variation of radon concentration in the monitored schools. Moreover, a quality assurance protocol was followed to reduce extra-exposures during detector transport from Rome to schools measured and back.",
journal = "Radiation Protection Dosimetry",
title = "Assessment of Long-Term Radon Concentration Measurement Precision in Field Conditions (Serbian Schools) for a Survey Carried Out By An International Collaboration",
volume = "145",
number = "2-3",
pages = "305-311",
doi = "10.1093/rpd/ncr042"
}
Carpentieri, C., Žunić, Z. S., Carelli, V., Cordedda, C., Ferrigno, G., Veselinović, N., Bossew, P., Tollefsen, T. B., Cuknic, O., Vojinovic, Z.,& Bochicchio, F.. (2011). Assessment of Long-Term Radon Concentration Measurement Precision in Field Conditions (Serbian Schools) for a Survey Carried Out By An International Collaboration. in Radiation Protection Dosimetry, 145(2-3), 305-311.
https://doi.org/10.1093/rpd/ncr042
Carpentieri C, Žunić ZS, Carelli V, Cordedda C, Ferrigno G, Veselinović N, Bossew P, Tollefsen TB, Cuknic O, Vojinovic Z, Bochicchio F. Assessment of Long-Term Radon Concentration Measurement Precision in Field Conditions (Serbian Schools) for a Survey Carried Out By An International Collaboration. in Radiation Protection Dosimetry. 2011;145(2-3):305-311.
doi:10.1093/rpd/ncr042 .
Carpentieri, Carmen, Žunić, Zora S., Carelli, V., Cordedda, C., Ferrigno, G., Veselinović, Nenad, Bossew, Peter, Tollefsen, Tore B., Cuknic, O., Vojinovic, Z., Bochicchio, Francesco, "Assessment of Long-Term Radon Concentration Measurement Precision in Field Conditions (Serbian Schools) for a Survey Carried Out By An International Collaboration" in Radiation Protection Dosimetry, 145, no. 2-3 (2011):305-311,
https://doi.org/10.1093/rpd/ncr042 . .
12
14
14