Influence of Reference Field Spectra on Calibration of Field Class Dosimeters

Živanović, Miloš Z.; Šabeta, Amra; Kržanović, Nikola; Makarić, Vedrana; Đaletić, Miloš; Stupar, Milica; Stanković, Srboljub

(Institut za nuklearne nauke "Vinča", 2021)

TY  - CONF
AU  - Živanović, Miloš Z.
AU  - Šabeta, Amra
AU  - Kržanović, Nikola
AU  - Makarić, Vedrana
AU  - Đaletić, Miloš
AU  - Stupar, Milica
AU  - Stanković, Srboljub
PY  - 2021
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10087
AB  - Active electronic dosimeters are usually calibrated in Secondary Standards Dosimetry Laboratories in reference photon fields, with the uncertainty which is typically around 5 % (k=2). Reference fields are established in accordance with relevant international standards – usually ISO 4037 for photon radiation. Some differences in spectra between different laboratories are unavoidable, but the effect on reference dose rates is well studied and within the above mentioned measurement uncertainty, and this is confirmed by existing interlaboratory comparisons. However, many field class dosimeters have poor energy dependence, especially in the energy range below 100 keV, which could cause large differences in calibration factors determined in different calibration laboratories under nominally the same conditions. This may also have implications for dosimeter testing or verification. In this paper, preliminary results obtained in two different calibration laboratories are presented.
AB  - Aktivni elektronski dozimetri se najčešće etaloniraju u Sekundarnim standardnim dozimetrijskim laboratorijama u referentnim poljima fotonskog zračenja, sa mernom nesigurnošću od oko 5 % (k=2). Referentna polja se uspostavljaju u skladu sa međunarodnim standardima, obično ISO 4037 za fotonsko zračenje. Male razlike u spektrima u različitim laboratorijama su neizbežne, ali je efekat na referentne vrednosti dobro proučen i ostaje u okviru mernih nesigurnosti, što je potvrđeno postojećim međulaboratorijskim poređenjima. Međutim, mnogi korisnički dozimetri imaju lošu energetsku zavisnost, pogotovo u opsegu energija ispod 100 keV, što može da uzrokuje velike razlike u kalibracionim faktorima određenim u različitim laboratorijama u nominalno istim uslovima. To može da ima posledice i na ispitivanje ili overavanje dozimetara. U ovom radu su prikazani prvi rezultati dobijeni u dve različite laboratorije za etaloniranje.
PB  - Institut za nuklearne nauke "Vinča"
PB  - Društvo za zaštitu od zračenja Srbije i Crne Gore
C3  - 31. симпозијум ДЗЗСЦГ : зборник радова
T1  - Influence of Reference Field Spectra on Calibration of Field Class Dosimeters
T1  - Uticaj spektara referentnih polja na etaloniranje korisničkih dozimetara
SP  - 194
EP  - 199
UR  - https://hdl.handle.net/21.15107/rcub_vinar_10087
ER  - 
@conference{
author = "Živanović, Miloš Z. and Šabeta, Amra and Kržanović, Nikola and Makarić, Vedrana and Đaletić, Miloš and Stupar, Milica and Stanković, Srboljub",
year = "2021",
abstract = "Active electronic dosimeters are usually calibrated in Secondary Standards Dosimetry Laboratories in reference photon fields, with the uncertainty which is typically around 5 % (k=2). Reference fields are established in accordance with relevant international standards – usually ISO 4037 for photon radiation. Some differences in spectra between different laboratories are unavoidable, but the effect on reference dose rates is well studied and within the above mentioned measurement uncertainty, and this is confirmed by existing interlaboratory comparisons. However, many field class dosimeters have poor energy dependence, especially in the energy range below 100 keV, which could cause large differences in calibration factors determined in different calibration laboratories under nominally the same conditions. This may also have implications for dosimeter testing or verification. In this paper, preliminary results obtained in two different calibration laboratories are presented., Aktivni elektronski dozimetri se najčešće etaloniraju u Sekundarnim standardnim dozimetrijskim laboratorijama u referentnim poljima fotonskog zračenja, sa mernom nesigurnošću od oko 5 % (k=2). Referentna polja se uspostavljaju u skladu sa međunarodnim standardima, obično ISO 4037 za fotonsko zračenje. Male razlike u spektrima u različitim laboratorijama su neizbežne, ali je efekat na referentne vrednosti dobro proučen i ostaje u okviru mernih nesigurnosti, što je potvrđeno postojećim međulaboratorijskim poređenjima. Međutim, mnogi korisnički dozimetri imaju lošu energetsku zavisnost, pogotovo u opsegu energija ispod 100 keV, što može da uzrokuje velike razlike u kalibracionim faktorima određenim u različitim laboratorijama u nominalno istim uslovima. To može da ima posledice i na ispitivanje ili overavanje dozimetara. U ovom radu su prikazani prvi rezultati dobijeni u dve različite laboratorije za etaloniranje.",
publisher = "Institut za nuklearne nauke "Vinča", Društvo za zaštitu od zračenja Srbije i Crne Gore",
journal = "31. симпозијум ДЗЗСЦГ : зборник радова",
title = "Influence of Reference Field Spectra on Calibration of Field Class Dosimeters, Uticaj spektara referentnih polja na etaloniranje korisničkih dozimetara",
pages = "194-199",
url = "https://hdl.handle.net/21.15107/rcub_vinar_10087"
}
Živanović, M. Z., Šabeta, A., Kržanović, N., Makarić, V., Đaletić, M., Stupar, M.,& Stanković, S.. (2021). Influence of Reference Field Spectra on Calibration of Field Class Dosimeters. in 31. симпозијум ДЗЗСЦГ : зборник радова
Institut za nuklearne nauke "Vinča"., 194-199.
https://hdl.handle.net/21.15107/rcub_vinar_10087
Živanović MZ, Šabeta A, Kržanović N, Makarić V, Đaletić M, Stupar M, Stanković S. Influence of Reference Field Spectra on Calibration of Field Class Dosimeters. in 31. симпозијум ДЗЗСЦГ : зборник радова. 2021;:194-199.
https://hdl.handle.net/21.15107/rcub_vinar_10087 .
Živanović, Miloš Z., Šabeta, Amra, Kržanović, Nikola, Makarić, Vedrana, Đaletić, Miloš, Stupar, Milica, Stanković, Srboljub, "Influence of Reference Field Spectra on Calibration of Field Class Dosimeters" in 31. симпозијум ДЗЗСЦГ : зборник радова (2021):194-199,
https://hdl.handle.net/21.15107/rcub_vinar_10087 .

EURAMET i DOSEtrace projekat i dodatna interkomparacija

Živanović, Miloš Z.; Hupe, Oliver; Šabeta, Amra; Kržanović, Nikola; Makarić, Vedrana

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2019)

TY  - CONF
AU  - Živanović, Miloš Z.
AU  - Hupe, Oliver
AU  - Šabeta, Amra
AU  - Kržanović, Nikola
AU  - Makarić, Vedrana
PY  - 2019
UR  - https://plus.sr.cobiss.net/opac7/bib/279687436
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8717
AB  - Tačna i sledljiva merenja operativnih veličina su neophodna za adekvatnu zaštitu od zračenja. Nacionalni metrološki instituti i Imenovani instituti su zaduženi za diseminaciju SI jedinice Sivert i za etaloniranje korisničke opreme. Ipak, u velikom broju Evropskih zemalja, mogušnosti etaloniranjaza operativne veličine su nedovoljno razvijene ili nepostoješe. Glavni cilj DOSEtrace projekta je unapređenje ovih mogućnosti, kao i smanjenje proširene merne nesigurnosti učesnika projekta ispod 5 % (k = 2). U okviru projekta še biti sprovedena Dodatna interkomparacija kalibracionih faktora za ambijentalni dozni ekvivalent. Ova interkomparacija še pomoši učesnicima projekta da validiraju merne mogušnosti razvijene pre i tokom projekta, a takođe će pomoći novim institutima da steknu međunarodno priznanje. U okviru intercomparacije, biše pokriveni kvaliteti zračenja radionuklida, kao i x-zračenja.
AB  - Accurate and traceable measurements of operational quantities are required for adequate radiation protection. National Measurement Institutes (NMI) and Designated Institutes (DI) are responsible for disseminating the SI unit sievert and for calibrating user equipment. However, in many emerging European countries, calibration and measurement capabilities for operational quantities are limited or nonexistent. The main objective of DOSEtrace project is to improve these capabilities and for the participants to achieve the expanded measurement uncertainty of less than5% (k = 2). Within the project, a Supplementary comparison of calibration factors in terms of ambient dose equivalent will be conducted. This comparison will help to validate the capabilities that the partners developed during and before the project and will help emerging institutes gain international recognition. The comparison will cover both radionuclide and x-ray radiation qualities according to ISO 4037-1.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 30. симпозијум ДЗЗСЦГ : зборник радова
T1  - EURAMET i DOSEtrace projekat i dodatna interkomparacija
T1  - EURAMET i DOSEtrace project and supplementary comparison
SP  - 472
EP  - 477
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8717
ER  - 
@conference{
author = "Živanović, Miloš Z. and Hupe, Oliver and Šabeta, Amra and Kržanović, Nikola and Makarić, Vedrana",
year = "2019",
abstract = "Tačna i sledljiva merenja operativnih veličina su neophodna za adekvatnu zaštitu od zračenja. Nacionalni metrološki instituti i Imenovani instituti su zaduženi za diseminaciju SI jedinice Sivert i za etaloniranje korisničke opreme. Ipak, u velikom broju Evropskih zemalja, mogušnosti etaloniranjaza operativne veličine su nedovoljno razvijene ili nepostoješe. Glavni cilj DOSEtrace projekta je unapređenje ovih mogućnosti, kao i smanjenje proširene merne nesigurnosti učesnika projekta ispod 5 % (k = 2). U okviru projekta še biti sprovedena Dodatna interkomparacija kalibracionih faktora za ambijentalni dozni ekvivalent. Ova interkomparacija še pomoši učesnicima projekta da validiraju merne mogušnosti razvijene pre i tokom projekta, a takođe će pomoći novim institutima da steknu međunarodno priznanje. U okviru intercomparacije, biše pokriveni kvaliteti zračenja radionuklida, kao i x-zračenja., Accurate and traceable measurements of operational quantities are required for adequate radiation protection. National Measurement Institutes (NMI) and Designated Institutes (DI) are responsible for disseminating the SI unit sievert and for calibrating user equipment. However, in many emerging European countries, calibration and measurement capabilities for operational quantities are limited or nonexistent. The main objective of DOSEtrace project is to improve these capabilities and for the participants to achieve the expanded measurement uncertainty of less than5% (k = 2). Within the project, a Supplementary comparison of calibration factors in terms of ambient dose equivalent will be conducted. This comparison will help to validate the capabilities that the partners developed during and before the project and will help emerging institutes gain international recognition. The comparison will cover both radionuclide and x-ray radiation qualities according to ISO 4037-1.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "30. симпозијум ДЗЗСЦГ : зборник радова",
title = "EURAMET i DOSEtrace projekat i dodatna interkomparacija, EURAMET i DOSEtrace project and supplementary comparison",
pages = "472-477",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8717"
}
Živanović, M. Z., Hupe, O., Šabeta, A., Kržanović, N.,& Makarić, V.. (2019). EURAMET i DOSEtrace projekat i dodatna interkomparacija. in 30. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 472-477.
https://hdl.handle.net/21.15107/rcub_vinar_8717
Živanović MZ, Hupe O, Šabeta A, Kržanović N, Makarić V. EURAMET i DOSEtrace projekat i dodatna interkomparacija. in 30. симпозијум ДЗЗСЦГ : зборник радова. 2019;:472-477.
https://hdl.handle.net/21.15107/rcub_vinar_8717 .
Živanović, Miloš Z., Hupe, Oliver, Šabeta, Amra, Kržanović, Nikola, Makarić, Vedrana, "EURAMET i DOSEtrace projekat i dodatna interkomparacija" in 30. симпозијум ДЗЗСЦГ : зборник радова (2019):472-477,
https://hdl.handle.net/21.15107/rcub_vinar_8717 .

EURAMET Dosetrace project and Supplementary comparison

Živanović, Miloš; Hupe, Oliver; Šabeta, Amra; Kržanović, Nikola; Makarić, Vedrana

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2019)

TY  - CONF
AU  - Živanović, Miloš
AU  - Hupe, Oliver
AU  - Šabeta, Amra
AU  - Kržanović, Nikola
AU  - Makarić, Vedrana
PY  - 2019
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11921
AB  - Accurate and traceable measurements of operational quantities are required for adequate radiation protection. National Measurement Institutes (NMI) and Designated Institutes (DI) are responsible for disseminating the SI unit sievert and for calibrating user equipment. However, in many emerging European countries, calibration and measurement capabilities for operational quantities are limited or nonexistent. The main objective of DOSEtrace project is to improve these capabilities and for the participants to achieve the expanded measurement uncertainty of less than 5% (k = 2). Within the project, a Supplementary comparison of calibration factors in terms of ambient dose equivalent will be conducted. This comparison will help to validate the capabilities that the partners developed during and before the project and will help emerging institutes gain international recognition. The comparison will cover both radionuclide and x-ray radiation qualities according to ISO 4037-1.
AB  - Taţna i sledljiva merenja operativnih veliţina su neophodna za adekvatnu zaštitu od
zraţenja. Nacionalni metrološki instituti i Imenovani instituti su zaduţeni za
diseminaciju SI jedinice Sivert i za etaloniranje korisniţke opreme. Ipak, u velikom
broju Evropskih zemalja, mogušnosti etaloniranja za operativne veliţine su nedovoljno
razvijene ili nepostoješe. Glavni cilj DOSEtrace projekta je unapreŤenje ovih mogušnosti, kao i smanjenje proširene merne nesigurnosti uţesnika projekta ispod 5 % (k = 2).
U okviru projekta še biti sprovedena Dodatna interkomparacija kalibracionih faktora za
ambijentalni dozni ekvivalent. Ova interkomparacija še pomoši uţesnicima projekta da
validiraju merne mogušnosti razvijene pre i tokom projekta, a takoŤe še pomoši novim
institutima da steknu meŤunarodno priznanje. U okviru intercomparacije, biše pokriveni
kvaliteti zraţenja radionuklida, kao i x-zraţenja.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 30. симпозијум ДЗЗСЦГ : зборник радова
T1  - EURAMET Dosetrace project and Supplementary comparison
T1  - EURAMET Dosetrace projekat i dodatna interkomparacija
SP  - 472
EP  - 477
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11921
ER  - 
@conference{
author = "Živanović, Miloš and Hupe, Oliver and Šabeta, Amra and Kržanović, Nikola and Makarić, Vedrana",
year = "2019",
abstract = "Accurate and traceable measurements of operational quantities are required for adequate radiation protection. National Measurement Institutes (NMI) and Designated Institutes (DI) are responsible for disseminating the SI unit sievert and for calibrating user equipment. However, in many emerging European countries, calibration and measurement capabilities for operational quantities are limited or nonexistent. The main objective of DOSEtrace project is to improve these capabilities and for the participants to achieve the expanded measurement uncertainty of less than 5% (k = 2). Within the project, a Supplementary comparison of calibration factors in terms of ambient dose equivalent will be conducted. This comparison will help to validate the capabilities that the partners developed during and before the project and will help emerging institutes gain international recognition. The comparison will cover both radionuclide and x-ray radiation qualities according to ISO 4037-1., Taţna i sledljiva merenja operativnih veliţina su neophodna za adekvatnu zaštitu od
zraţenja. Nacionalni metrološki instituti i Imenovani instituti su zaduţeni za
diseminaciju SI jedinice Sivert i za etaloniranje korisniţke opreme. Ipak, u velikom
broju Evropskih zemalja, mogušnosti etaloniranja za operativne veliţine su nedovoljno
razvijene ili nepostoješe. Glavni cilj DOSEtrace projekta je unapreŤenje ovih mogušnosti, kao i smanjenje proširene merne nesigurnosti uţesnika projekta ispod 5 % (k = 2).
U okviru projekta še biti sprovedena Dodatna interkomparacija kalibracionih faktora za
ambijentalni dozni ekvivalent. Ova interkomparacija še pomoši uţesnicima projekta da
validiraju merne mogušnosti razvijene pre i tokom projekta, a takoŤe še pomoši novim
institutima da steknu meŤunarodno priznanje. U okviru intercomparacije, biše pokriveni
kvaliteti zraţenja radionuklida, kao i x-zraţenja.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "30. симпозијум ДЗЗСЦГ : зборник радова",
title = "EURAMET Dosetrace project and Supplementary comparison, EURAMET Dosetrace projekat i dodatna interkomparacija",
pages = "472-477",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11921"
}
Živanović, M., Hupe, O., Šabeta, A., Kržanović, N.,& Makarić, V.. (2019). EURAMET Dosetrace project and Supplementary comparison. in 30. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 472-477.
https://hdl.handle.net/21.15107/rcub_vinar_11921
Živanović M, Hupe O, Šabeta A, Kržanović N, Makarić V. EURAMET Dosetrace project and Supplementary comparison. in 30. симпозијум ДЗЗСЦГ : зборник радова. 2019;:472-477.
https://hdl.handle.net/21.15107/rcub_vinar_11921 .
Živanović, Miloš, Hupe, Oliver, Šabeta, Amra, Kržanović, Nikola, Makarić, Vedrana, "EURAMET Dosetrace project and Supplementary comparison" in 30. симпозијум ДЗЗСЦГ : зборник радова (2019):472-477,
https://hdl.handle.net/21.15107/rcub_vinar_11921 .

Određivanje uniformnosti i veličine referentnog polja X-zračenja

Makarić, Vedrana; Živanović, Miloš Z.; Kržanović, Nikola; Đaletić, Miloš

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2019)

TY  - CONF
AU  - Makarić, Vedrana
AU  - Živanović, Miloš Z.
AU  - Kržanović, Nikola
AU  - Đaletić, Miloš
PY  - 2019
UR  - https://plus.sr.cobiss.net/opac7/bib/279687436
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8716
AB  - Cilj ovog rada je da se ispita uniformnost i veličina referentnog polja generisanog pomoću generatora X-zračenja. U tu svrhu je koriššena jonizaciona komora male zapremine tako što su mapirane jačine doze. Na osnovu merenja, određen je korekcioni faktor za neuniformnost polja zračenja. Rezultati prikazani u ovom radu se odnose na polje kolimisano pomoću aperture prečnika 4,2 cm i generisano pomoću generatora X-zračenja konstantnog napona i struje. Ispitivanje je izvršeno u kvalitetu zračenja koji se koristi u dijagnostičkoj radiologiji, ali je ova procedura takođe primenjiva i na kvalitete koji se koriste za etaloniranje uređaja za zaštitu od zračenja definisane u novoj verziji ISO 4037 iz 2019. godine.
AB  - The aim of this paper is to study the uniformity and the size of a reference radiation field produced by an x-ray generator. This work uses a technique to map dose distribution and measure dose rates with a small-volume spherical ionization chamber in order to determine the correction factor for non uniformity of the radiation field. Results shown in this paper are profile measurementsperformed in radiation beam collimated by a 4.2 cm diameter aperture, generated by calibration x-ray equipment of constant voltage and current. Thestudy was conducted in a diagnostic radiology radiation quality, but this procedure is also applicable to the new revised version of ISO 4037 standard from 2019 which specifies protection level reference radiation qualities.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 30. симпозијум ДЗЗСЦГ : зборник радова
T1  - Određivanje uniformnosti i veličine referentnog polja X-zračenja
T1  - Determination of uniformity and field size of reference X-ray beams
SP  - 451
EP  - 456
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8716
ER  - 
@conference{
author = "Makarić, Vedrana and Živanović, Miloš Z. and Kržanović, Nikola and Đaletić, Miloš",
year = "2019",
abstract = "Cilj ovog rada je da se ispita uniformnost i veličina referentnog polja generisanog pomoću generatora X-zračenja. U tu svrhu je koriššena jonizaciona komora male zapremine tako što su mapirane jačine doze. Na osnovu merenja, određen je korekcioni faktor za neuniformnost polja zračenja. Rezultati prikazani u ovom radu se odnose na polje kolimisano pomoću aperture prečnika 4,2 cm i generisano pomoću generatora X-zračenja konstantnog napona i struje. Ispitivanje je izvršeno u kvalitetu zračenja koji se koristi u dijagnostičkoj radiologiji, ali je ova procedura takođe primenjiva i na kvalitete koji se koriste za etaloniranje uređaja za zaštitu od zračenja definisane u novoj verziji ISO 4037 iz 2019. godine., The aim of this paper is to study the uniformity and the size of a reference radiation field produced by an x-ray generator. This work uses a technique to map dose distribution and measure dose rates with a small-volume spherical ionization chamber in order to determine the correction factor for non uniformity of the radiation field. Results shown in this paper are profile measurementsperformed in radiation beam collimated by a 4.2 cm diameter aperture, generated by calibration x-ray equipment of constant voltage and current. Thestudy was conducted in a diagnostic radiology radiation quality, but this procedure is also applicable to the new revised version of ISO 4037 standard from 2019 which specifies protection level reference radiation qualities.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "30. симпозијум ДЗЗСЦГ : зборник радова",
title = "Određivanje uniformnosti i veličine referentnog polja X-zračenja, Determination of uniformity and field size of reference X-ray beams",
pages = "451-456",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8716"
}
Makarić, V., Živanović, M. Z., Kržanović, N.,& Đaletić, M.. (2019). Određivanje uniformnosti i veličine referentnog polja X-zračenja. in 30. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 451-456.
https://hdl.handle.net/21.15107/rcub_vinar_8716
Makarić V, Živanović MZ, Kržanović N, Đaletić M. Određivanje uniformnosti i veličine referentnog polja X-zračenja. in 30. симпозијум ДЗЗСЦГ : зборник радова. 2019;:451-456.
https://hdl.handle.net/21.15107/rcub_vinar_8716 .
Makarić, Vedrana, Živanović, Miloš Z., Kržanović, Nikola, Đaletić, Miloš, "Određivanje uniformnosti i veličine referentnog polja X-zračenja" in 30. симпозијум ДЗЗСЦГ : зборник радова (2019):451-456,
https://hdl.handle.net/21.15107/rcub_vinar_8716 .