Šabeta, Amra

Link to this page

Authority KeyName Variants
2fff2ea0-e04e-4e94-a25a-209bd5b0af56
  • Šabeta, Amra (1)
Projects

Author's Bibliography

EURAMET DOSEtrace supplementary comparison in terms of the ambient dose equivalent/rate for photon radiation (EURAMET.RI(I)-S18)

Živanović, Miloš; Hupe, Oliver; Zutz, Hayo; Šabeta, Amra; Sandtner, Stanislav; Kržanović, Nikola

(2023)

TY  - JOUR
AU  - Živanović, Miloš
AU  - Hupe, Oliver
AU  - Zutz, Hayo
AU  - Šabeta, Amra
AU  - Sandtner, Stanislav
AU  - Kržanović, Nikola
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11371
AB  - Supplementary comparison in terms of the ambient dose equivalent/rate was organized within EURAMET as a part of the DOSEtrace project, between 13 national metrology institutes and designated institutes. Calibration coefficients were compared for a secondary standard ionisation chamber for 3 X-ray and 2 γ-ray radiation qualities used in the field of radiation protection. Radiation qualities were established according to ISO 4037-1. Measurements were performed between 2019 and 2021. For the purpose of this comparison, it was considered that the reported uncertainty was confirmed if the relative deviation from the comparison reference value was smaller than or equal to the associated uncertainty. All the reported results by all the partners satisfied this criterium. Three participants were not able to perform calibrations in all mandatory radiation qualities, due to technical problems. The results are published in the Key Comparison Data Base (KCDB) of the BIPM as supplementary comparison EURAMET.RI(I)-S18. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). © 2023 BIPM & IOP Publishing Ltd.
T2  - Metrologia
T1  - EURAMET DOSEtrace supplementary comparison in terms of the ambient dose equivalent/rate for photon radiation (EURAMET.RI(I)-S18)
VL  - 60
IS  - 1A
SP  - 06017
DO  - 10.1088/0026-1394/60/1A/06017
ER  - 
@article{
author = "Živanović, Miloš and Hupe, Oliver and Zutz, Hayo and Šabeta, Amra and Sandtner, Stanislav and Kržanović, Nikola",
year = "2023",
abstract = "Supplementary comparison in terms of the ambient dose equivalent/rate was organized within EURAMET as a part of the DOSEtrace project, between 13 national metrology institutes and designated institutes. Calibration coefficients were compared for a secondary standard ionisation chamber for 3 X-ray and 2 γ-ray radiation qualities used in the field of radiation protection. Radiation qualities were established according to ISO 4037-1. Measurements were performed between 2019 and 2021. For the purpose of this comparison, it was considered that the reported uncertainty was confirmed if the relative deviation from the comparison reference value was smaller than or equal to the associated uncertainty. All the reported results by all the partners satisfied this criterium. Three participants were not able to perform calibrations in all mandatory radiation qualities, due to technical problems. The results are published in the Key Comparison Data Base (KCDB) of the BIPM as supplementary comparison EURAMET.RI(I)-S18. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). © 2023 BIPM & IOP Publishing Ltd.",
journal = "Metrologia",
title = "EURAMET DOSEtrace supplementary comparison in terms of the ambient dose equivalent/rate for photon radiation (EURAMET.RI(I)-S18)",
volume = "60",
number = "1A",
pages = "06017",
doi = "10.1088/0026-1394/60/1A/06017"
}
Živanović, M., Hupe, O., Zutz, H., Šabeta, A., Sandtner, S.,& Kržanović, N.. (2023). EURAMET DOSEtrace supplementary comparison in terms of the ambient dose equivalent/rate for photon radiation (EURAMET.RI(I)-S18). in Metrologia, 60(1A), 06017.
https://doi.org/10.1088/0026-1394/60/1A/06017
Živanović M, Hupe O, Zutz H, Šabeta A, Sandtner S, Kržanović N. EURAMET DOSEtrace supplementary comparison in terms of the ambient dose equivalent/rate for photon radiation (EURAMET.RI(I)-S18). in Metrologia. 2023;60(1A):06017.
doi:10.1088/0026-1394/60/1A/06017 .
Živanović, Miloš, Hupe, Oliver, Zutz, Hayo, Šabeta, Amra, Sandtner, Stanislav, Kržanović, Nikola, "EURAMET DOSEtrace supplementary comparison in terms of the ambient dose equivalent/rate for photon radiation (EURAMET.RI(I)-S18)" in Metrologia, 60, no. 1A (2023):06017,
https://doi.org/10.1088/0026-1394/60/1A/06017 . .