Coincidence summing corrections for point and volume Eu-152 sources
Samo za registrovane korisnike
2016
Autori
Novković, Dušan N.Đurašević, Mirjana M.
Kandić, Aleksandar
Vukanac, Ivana
Šešlak, Bojan Ž.
Milošević, Zoran
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
In this article, the X-ray and gamma-ray coincidence summing effect in Eu-152 is studied. Coincidence summing corrections and peak and total efficiencies of point and volume sources were determined using the direct matrices multiplication (DMM) method. The theoretically evaluated peak count rates were found to be in good agreement with the experimentally obtained values. Validation was performed by comparing the calculated efficiency curves and the corresponding correction factors with the results obtained using GESPECOR 4.2 software. (C) 2015 Elsevier Ltd. All rights reserved.
Ključne reči:
Gamma-ray spectrometry / Eu-152 / Coincidence summing correctionsIzvor:
Applied Radiation and Isotopes, 2016, 107, 138-144Finansiranje / projekti:
- Nuklearna fizika, metode i primena (RS-MESTD-Basic Research (BR or ON)-171018)
DOI: 10.1016/j.apradiso.2015.10.015
ISSN: 0969-8043
PubMed: 26496693
WoS: 000367410300023
Scopus: 2-s2.0-84944937064
Kolekcije
Institucija/grupa
VinčaTY - JOUR AU - Novković, Dušan N. AU - Đurašević, Mirjana M. AU - Kandić, Aleksandar AU - Vukanac, Ivana AU - Šešlak, Bojan Ž. AU - Milošević, Zoran PY - 2016 UR - https://vinar.vin.bg.ac.rs/handle/123456789/876 AB - In this article, the X-ray and gamma-ray coincidence summing effect in Eu-152 is studied. Coincidence summing corrections and peak and total efficiencies of point and volume sources were determined using the direct matrices multiplication (DMM) method. The theoretically evaluated peak count rates were found to be in good agreement with the experimentally obtained values. Validation was performed by comparing the calculated efficiency curves and the corresponding correction factors with the results obtained using GESPECOR 4.2 software. (C) 2015 Elsevier Ltd. All rights reserved. T2 - Applied Radiation and Isotopes T1 - Coincidence summing corrections for point and volume Eu-152 sources VL - 107 SP - 138 EP - 144 DO - 10.1016/j.apradiso.2015.10.015 ER -
@article{ author = "Novković, Dušan N. and Đurašević, Mirjana M. and Kandić, Aleksandar and Vukanac, Ivana and Šešlak, Bojan Ž. and Milošević, Zoran", year = "2016", abstract = "In this article, the X-ray and gamma-ray coincidence summing effect in Eu-152 is studied. Coincidence summing corrections and peak and total efficiencies of point and volume sources were determined using the direct matrices multiplication (DMM) method. The theoretically evaluated peak count rates were found to be in good agreement with the experimentally obtained values. Validation was performed by comparing the calculated efficiency curves and the corresponding correction factors with the results obtained using GESPECOR 4.2 software. (C) 2015 Elsevier Ltd. All rights reserved.", journal = "Applied Radiation and Isotopes", title = "Coincidence summing corrections for point and volume Eu-152 sources", volume = "107", pages = "138-144", doi = "10.1016/j.apradiso.2015.10.015" }
Novković, D. N., Đurašević, M. M., Kandić, A., Vukanac, I., Šešlak, B. Ž.,& Milošević, Z.. (2016). Coincidence summing corrections for point and volume Eu-152 sources. in Applied Radiation and Isotopes, 107, 138-144. https://doi.org/10.1016/j.apradiso.2015.10.015
Novković DN, Đurašević MM, Kandić A, Vukanac I, Šešlak BŽ, Milošević Z. Coincidence summing corrections for point and volume Eu-152 sources. in Applied Radiation and Isotopes. 2016;107:138-144. doi:10.1016/j.apradiso.2015.10.015 .
Novković, Dušan N., Đurašević, Mirjana M., Kandić, Aleksandar, Vukanac, Ivana, Šešlak, Bojan Ž., Milošević, Zoran, "Coincidence summing corrections for point and volume Eu-152 sources" in Applied Radiation and Isotopes, 107 (2016):138-144, https://doi.org/10.1016/j.apradiso.2015.10.015 . .