Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications
Samo za registrovane korisnike
2019
Autori
Stanković, Dalibor M.Ognjanović, Miloš
Jović, Milica
Cuplić, Valentina
Lesch, Andreas
Girault, Hubert H.
Gavrović-Jankulović, Marija
Antić, Bratislav
Članak u časopisu (Objavljena verzija)
,
© 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
A disposable acetaminophen biosensor based on inkjet-printed CNT electrodes (IJPCNT) modified with amidase/cerium dioxide@graphene nanoribbons composite was developed (ACeO2@GNR/IJPCNT). The enzyme amidase A was used for the first time as a recognition element. Inkjet-printed CNT electrodes served as a basis for the construction of a biosensor that enables droplet detection using 5 μL sample volume. The biosensor showed high selectivity, sensitivity, a low detection limit of 0.18 μM and a wide working linear range from 1 to 100 μM. The proposed approach allows fast and reliable detection of acetaminophen in biological fluids with negligible matrix effect and remarkable reproducibility. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
Ključne reči:
acetaminophen / amidase / biosensor / cerium dioxide / graphene nanoribbons composite / inkjet-printed sensorsIzvor:
Electroanalysis, 2019, 31, 8, 1517-1525Finansiranje / projekti:
- Strengthening of the MagBioVin Research and Innovation Team for Development of Novel Approaches for Tumour Therapy based on Nanostructured Materials (EU-FP7-621375)
- Primena unapređenih oksidacionih procesa i nanostrukturisanih oksidnih materijala za uklanjanje zagađivača iz životne sredine, razvoj i optimizacija instrumentalnih tehnika za praćenje efikasnosti (RS-MESTD-Basic Research (BR or ON)-172030)
- Alergeni, antitela, enzimi i mali fiziološki značajni molekuli: dizajn, struktura, funkcija i značaj (RS-MESTD-Basic Research (BR or ON)-172049)
DOI: 10.1002/elan.201900129
ISSN: 1040-0397; 1521-4109
WoS: 000479081100015
Scopus: 2-s2.0-85066899420
Kolekcije
Institucija/grupa
VinčaTY - JOUR AU - Stanković, Dalibor M. AU - Ognjanović, Miloš AU - Jović, Milica AU - Cuplić, Valentina AU - Lesch, Andreas AU - Girault, Hubert H. AU - Gavrović-Jankulović, Marija AU - Antić, Bratislav PY - 2019 UR - https://vinar.vin.bg.ac.rs/handle/123456789/8342 AB - A disposable acetaminophen biosensor based on inkjet-printed CNT electrodes (IJPCNT) modified with amidase/cerium dioxide@graphene nanoribbons composite was developed (ACeO2@GNR/IJPCNT). The enzyme amidase A was used for the first time as a recognition element. Inkjet-printed CNT electrodes served as a basis for the construction of a biosensor that enables droplet detection using 5 μL sample volume. The biosensor showed high selectivity, sensitivity, a low detection limit of 0.18 μM and a wide working linear range from 1 to 100 μM. The proposed approach allows fast and reliable detection of acetaminophen in biological fluids with negligible matrix effect and remarkable reproducibility. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim T2 - Electroanalysis T1 - Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications VL - 31 IS - 8 SP - 1517 EP - 1525 DO - 10.1002/elan.201900129 ER -
@article{ author = "Stanković, Dalibor M. and Ognjanović, Miloš and Jović, Milica and Cuplić, Valentina and Lesch, Andreas and Girault, Hubert H. and Gavrović-Jankulović, Marija and Antić, Bratislav", year = "2019", abstract = "A disposable acetaminophen biosensor based on inkjet-printed CNT electrodes (IJPCNT) modified with amidase/cerium dioxide@graphene nanoribbons composite was developed (ACeO2@GNR/IJPCNT). The enzyme amidase A was used for the first time as a recognition element. Inkjet-printed CNT electrodes served as a basis for the construction of a biosensor that enables droplet detection using 5 μL sample volume. The biosensor showed high selectivity, sensitivity, a low detection limit of 0.18 μM and a wide working linear range from 1 to 100 μM. The proposed approach allows fast and reliable detection of acetaminophen in biological fluids with negligible matrix effect and remarkable reproducibility. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim", journal = "Electroanalysis", title = "Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications", volume = "31", number = "8", pages = "1517-1525", doi = "10.1002/elan.201900129" }
Stanković, D. M., Ognjanović, M., Jović, M., Cuplić, V., Lesch, A., Girault, H. H., Gavrović-Jankulović, M.,& Antić, B.. (2019). Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications. in Electroanalysis, 31(8), 1517-1525. https://doi.org/10.1002/elan.201900129
Stanković DM, Ognjanović M, Jović M, Cuplić V, Lesch A, Girault HH, Gavrović-Jankulović M, Antić B. Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications. in Electroanalysis. 2019;31(8):1517-1525. doi:10.1002/elan.201900129 .
Stanković, Dalibor M., Ognjanović, Miloš, Jović, Milica, Cuplić, Valentina, Lesch, Andreas, Girault, Hubert H., Gavrović-Jankulović, Marija, Antić, Bratislav, "Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications" in Electroanalysis, 31, no. 8 (2019):1517-1525, https://doi.org/10.1002/elan.201900129 . .