Show simple item record

Influence of efficiency calibration on determination of Be7 and Pb210 concentration in air

dc.creatorRajačić, Milica
dc.creatorTodorović, Dragana
dc.creatorKrneta-Nikolić, Jelena D.
dc.creatorVukanac, Ivana
dc.creatorPantelić, Gordana K.
dc.creatorSarap, Nataša
dc.creatorJanković, Marija M.
dc.date.accessioned2019-10-25T12:35:46Z
dc.date.available2019-10-25T12:35:46Z
dc.date.issued2017
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/8312
dc.identifier.urihttps://plus.sr.cobiss.net/opac7/bib/245691404
dc.identifier.urihttp://dzz.org.rs/wp-content/uploads/2013/06/Zbornik_XXIX_Simpozijum_DZZ_SCG_Srebrno_jezero_2.pdf
dc.description.abstractU ovom radu je prikazan pregled metoda kalibracije efikasnosti detektora za gamaspektromertijsko određivanje koncentracije 7Be (477,6 keV) i 210Pb (46 keV) u uzorcima vazduha u Laboratoriji za zaštitu odzračenja, Instituta "Vinča" u periodu od 1994. godine do danas. Za prvu procenu efikasnosti korišćeni su set tačkastih referentnih materijala (Coffret d’etalon ECGS-2, Sacle, Franse) i planšeta punjena aerosolnim prahom dobijenog za interkomparaciju u okviru projekta SEV, a od 2008. godine u upotrebi su laboratorijski referentni materijali u matriksu aerosolnog praha u geometriji fiole, pripremljeni sertifikovanim rastvorom radionuklida. Pređenjem vrednosti koncentracija 7Be i 210Pb dobijenih korišćenjem pojedinačnih metoda kalibracije, pokazan je njihov uticaj na rezultat merenja.sr
dc.description.abstractThis paper presents a review of efficiency calibration methods for gamma spectrometry detectors used in determination of 7 Be (477,6 keV) and 210Pb (46 keV) concentration in air samples, conducted in Radiation and Environment Protection Laboratory, Institute "Vinča", in the period from year 1994. up to date. The first efficiency estimate was performed using a set of point sources (Coffret d’etalon ECGS-2, Sacle, Franse), then a planchette, filled with aerosol dust obtained for the Proficiency test conducted within the framework of SEV project, while since year 2008. the laboratory reference materials are in use - the aerosol dust matrix placed in the vial, prepared by spiking with the certified radioactive solution. By comparing the values for 7 Be and 210Pb concentrations obtained using each of the mentioned calibration methods, the influence of the calibration method on the measurement results was shown.en
dc.language.isosrsr
dc.publisherБеоград : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Гореsr
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/43009/RS//sr
dc.rightsopenAccesssr
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.source29. симпозијум ДЗЗСЦГ : зборник радоваsr
dc.titleUticaj kalibracije efikasnosti na određivanje koncentracije Be7 i Pb210 u vazduhusr
dc.titleInfluence of efficiency calibration on determination of Be7 and Pb210 concentration in airen
dc.typeconferenceObjectsr
dc.rights.licenseBY-NC-NDsr
dcterms.abstractЈанковић, Марија М.; Пантелић, Гордана К.; Вуканац, Ивана; Крнета-Николић, Јелена Д.; Тодоровић, Драгана; Рајачић, Милица; Сарап, Наташа; Утицај калибрације ефикасности на одређивање концентрације Бе7 и Пб210 у ваздуху; Утицај калибрације ефикасности на одређивање концентрације Бе7 и Пб210 у ваздуху;
dc.rights.holder© Institut za nuklearne nauke „Vinča“sr
dc.citation.spage443
dc.citation.epage448
dc.description.otherЗборник радова : XXIX симпозијум ДЗЗСЦГ : Сребрно језеро, 27-29. септембар 2017. годинеsr
dc.type.versionpublishedVersionsr
dc.identifier.fulltexthttps://vinar.vin.bg.ac.rs/bitstream/id/20671/Rajacic_443.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_vinar_8312


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record