Comparison of TL spectra of co-doped dosimetric materials
Apstrakt
Wavelength resolved spectra of the dosimetric materials CaSO4 and MgB4O7 with the rare earth (RE) ions Dy and Tm are presented. The study of co-doped samples provides, within a single sample, unequivocal evidence of a glow peak displacement of the two dopants. In the case of the main dosimetric peak for CaSO4 at similar to 220 degrees C, a reproducible systematic temperature difference of 7 to 8 degrees C is observed between the glow peaks near 230 to 240 degrees C for Tm and Dy. No comparable displacement is detected between Tm and Dy for the main dosimetric peak for MgB4O7 at about 180 degrees C. However, higher temperature glow peaks above 300 degrees C display a noticeable displacement of Dy and Tm on the scale of 30 degrees C. This research provides further evidence supporting the view that the RE ions could form part of a complex defect acting as both charge trap and recombination centre.
Izvor:
Radiation Protection Dosimetry, 1999, 84, 1-4, 281-284Napomena:
- 12th International Conference on Solid State Dosimetry, Jul 05-10, 1998, Burgos, Spain
DOI: 10.1093/oxfordjournals.rpd.a032738
ISSN: 0144-8420
WoS: 000081587500066
Scopus: 2-s2.0-0032792968
Kolekcije
Institucija/grupa
VinčaTY - JOUR AU - Karali, Turgay AU - Townsend, Peter David AU - Prokić, Mirjana S. AU - Rowlands, Aled P. PY - 1999 UR - https://vinar.vin.bg.ac.rs/handle/123456789/6275 AB - Wavelength resolved spectra of the dosimetric materials CaSO4 and MgB4O7 with the rare earth (RE) ions Dy and Tm are presented. The study of co-doped samples provides, within a single sample, unequivocal evidence of a glow peak displacement of the two dopants. In the case of the main dosimetric peak for CaSO4 at similar to 220 degrees C, a reproducible systematic temperature difference of 7 to 8 degrees C is observed between the glow peaks near 230 to 240 degrees C for Tm and Dy. No comparable displacement is detected between Tm and Dy for the main dosimetric peak for MgB4O7 at about 180 degrees C. However, higher temperature glow peaks above 300 degrees C display a noticeable displacement of Dy and Tm on the scale of 30 degrees C. This research provides further evidence supporting the view that the RE ions could form part of a complex defect acting as both charge trap and recombination centre. T2 - Radiation Protection Dosimetry T1 - Comparison of TL spectra of co-doped dosimetric materials VL - 84 IS - 1-4 SP - 281 EP - 284 DO - 10.1093/oxfordjournals.rpd.a032738 ER -
@article{ author = "Karali, Turgay and Townsend, Peter David and Prokić, Mirjana S. and Rowlands, Aled P.", year = "1999", abstract = "Wavelength resolved spectra of the dosimetric materials CaSO4 and MgB4O7 with the rare earth (RE) ions Dy and Tm are presented. The study of co-doped samples provides, within a single sample, unequivocal evidence of a glow peak displacement of the two dopants. In the case of the main dosimetric peak for CaSO4 at similar to 220 degrees C, a reproducible systematic temperature difference of 7 to 8 degrees C is observed between the glow peaks near 230 to 240 degrees C for Tm and Dy. No comparable displacement is detected between Tm and Dy for the main dosimetric peak for MgB4O7 at about 180 degrees C. However, higher temperature glow peaks above 300 degrees C display a noticeable displacement of Dy and Tm on the scale of 30 degrees C. This research provides further evidence supporting the view that the RE ions could form part of a complex defect acting as both charge trap and recombination centre.", journal = "Radiation Protection Dosimetry", title = "Comparison of TL spectra of co-doped dosimetric materials", volume = "84", number = "1-4", pages = "281-284", doi = "10.1093/oxfordjournals.rpd.a032738" }
Karali, T., Townsend, P. D., Prokić, M. S.,& Rowlands, A. P.. (1999). Comparison of TL spectra of co-doped dosimetric materials. in Radiation Protection Dosimetry, 84(1-4), 281-284. https://doi.org/10.1093/oxfordjournals.rpd.a032738
Karali T, Townsend PD, Prokić MS, Rowlands AP. Comparison of TL spectra of co-doped dosimetric materials. in Radiation Protection Dosimetry. 1999;84(1-4):281-284. doi:10.1093/oxfordjournals.rpd.a032738 .
Karali, Turgay, Townsend, Peter David, Prokić, Mirjana S., Rowlands, Aled P., "Comparison of TL spectra of co-doped dosimetric materials" in Radiation Protection Dosimetry, 84, no. 1-4 (1999):281-284, https://doi.org/10.1093/oxfordjournals.rpd.a032738 . .