Претраживање
Приказ резултата 1-10 од 54
Ad-hoc intercomparison of four different radon exhalation measurement methods
(Radiation Protection Dosimetry, 2018)
It is indicated that the exposure to radon originating from the building materials is not negligible and the radon exhalation measurement should get more attention in the future. The experience with four different methods ...
A Study to Establish International Diagnostic Reference Levels for Paediatric Computed Tomography
(Radiation Protection Dosimetry, 2015)
The article reports from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index ...
Eye Dosimetry in Interventional Radiology and Cardiology: Current Challenges and Practical Considerations
(Radiation Protection Dosimetry, 2014)
Interventional radiology and cardiology are areas with high potential for risk to eye lens. Accurate assessment of eye dose is one of the most important aspects of correlating doses with observed lens opacities among workers ...
Sensitivity and fading of pMOS dosemeters irradiated with X-ray radiation doses from 1 to 100 cGy
(Radiation Protection Dosimetry, 2016)
In this paper, the results of pMOS dosemeters sensitivity to X-ray radiation and 28-d fading at room temperature are presented. Two types of dosemeters were used, which differ in gate oxide layer thickness. The sensitivity ...
First results on patient dose measurements from conventional diagnostic radiology procedures in Serbia and Montenegro
(Radiation Protection Dosimetry, 2005)
The objective of this work is to assess patient doses for the most frequent X-ray examinations for the first time in Serbia and Montenegro. A total of 510 procedures for 11 different examination categories in 3 general ...
Mammography practice in Serbia: evaluation and optimisation of image quality and the technical aspects of the mammographic imaging chain
(Radiation Protection Dosimetry, 2010)
The purpose of this work was to assess mammography practice in Serbia and its appropriateness for both diagnostic service and potential screening by implementing quality control (QC) protocol in three large teaching ...
Assessment of Long-Term Radon Concentration Measurement Precision in Field Conditions (Serbian Schools) for a Survey Carried Out By An International Collaboration
(Radiation Protection Dosimetry, 2011)
In an international collaboration, a long-term radon concentration survey was carried out in schools of Southern Serbia with radon detectors prepared, etched and read-out in Italy. In such surveys it is necessary to evaluate ...
Comparison of Different Methods for Shielding Design in Computed Tomography
(Radiation Protection Dosimetry, 2011)
The purpose of this work is to compare different methods for shielding calculation in computed tomography (CT). The BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) and NCRP ...
Status of Radiation Protection in Interventional Cardiology in Four East European Countries
(Radiation Protection Dosimetry, 2011)
Level of staff and patient radiation protection in interventional cardiology in four counties (Bosnia and Herzegovina, Croatia, Montenegro and Serbia) as a part of International Atomic Energy Agency project (RER/9/093) are ...
Paediatric Ct Examinations in 19 Developing Countries: Frequency. and Radiation Dose
(Radiation Protection Dosimetry, 2010)
The aims of this study were to investigate the frequency of computed tomography (CT) examinations for paediatric patients below 15 y of age in 128 CT facilities in 28 developing countries of Africa, Asia and Eastern Europe ...