Претраживање
Приказ резултата 11-20 од 54
Mammography Radiation Dose: Initial Results from Serbia Based on Mean Glandular Dose Assessment for Phantoms and Patients
(Radiation Protection Dosimetry, 2010)
The primary objective of this study is to investigate the actual mammography dose levels in Serbia and establish a baseline dose database for the future screening programme. The mean glandular dose (MGD) was assessed for ...
An evaluation of thoron (and radon) equilibrium factor close to walls based on long-term measurements in dwellings
(Radiation Protection Dosimetry, 2014)
Thoron gas and its progeny behave quite differently in room environments, owing to the difference in their half-lives; therefore, it is important to measure simultaneously gas and progeny concentrations to estimate the ...
Dose effect for South Serbians due to U-238 in natural drinking water
(Radiation Protection Dosimetry, 2007)
The use of depleted uranium ammunition in South Serbia during the 1999 Kosovo conflict raised a great deal of public concern in the Balkans. Radioactivity levels of U-238 in 20 wells and lake water samples were checked ...
Measurement of maximum skin dose in interventional radiology and cardiology and challenges in the set-up of European alert thresholds
(Radiation Protection Dosimetry, 2015)
To help operators acknowledge patient dose during interventional procedures, EURADOS WG-12 focused on measuring patient skin dose using XR-RV3 gafchromic films, thermoluminescent detector (TLD) pellets or 2D TL foils and ...
Patient doses for barium meal examination in Serbia and Montenegro and potentials for dose reduction through changes in equipment settings
(Radiation Protection Dosimetry, 2005)
Patient doses for barium meal examination performed at three general hospitals, in Serbia and Montenegro were measured using a kerma-area product (KAP) meter. The results were analysed in order to obtain dose-related ...
Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels
(Radiation Protection Dosimetry, 2013)
Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography ...
Indoor Radon, Thoron and Their Progeny Concentrations in High Thoron Rural Serbia Environments
(Radiation Protection Dosimetry, 2017)
This article deals with the variation of radon (Rn), thoron (Tn) and their progeny concentrations expressed in terms of equilibrium equivalent concentrations (EERC and EETC), in 40 houses, in four villages of Sokobanja ...
Air kerma rate constants for gamma emitters used most often in practice
(Radiation Protection Dosimetry, 2005)
It is often required to estimate the dose rate at a distance from radionuclides that are sources of X rays and gamma rays. Such calculations may be required for planning radiation protection measures in the vicinity of ...
Optically and thermally stimulated luminescence characteristics of MgO : Tb3+
(Radiation Protection Dosimetry, 2006)
In this paper main optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics are presented of a newly synthesised material MgO doped with terbium (Tb) developed at the Institute of Nuclear Science, ...
Results from Time Integrated Measurements of Indoor Radon, Thoron and Their Decay Product Concentrations in Schools in the Republic of Macedonia
(Radiation Protection Dosimetry, 2014)
As part of a survey on concentrations of radon, thoron and their decay products in different indoor environments of the Balkan region involving international collaboration, measurements were performed in 43 schools from 5 ...